HVAC + Electrical

Every Intry Tool, Free to Use

Pick your trade, then the job you are standing in front of. Calculators are the buttons; charts and guides are listed under them. The tools need no login and no email, and carry no ads.


Electrical: pick the job

Every code calculation names the NEC table and section it used. Open the electrical hub.


HVAC: pick the job

Load sizing, airflow, charge diagnostics, and the A2L transition, each number cited to its source. Open the HVAC hub.


The money side: pricing & margin


The Intry platform

Everything around the calculators: run any tool in your AI assistant, keep your readings as one job across visits, embed a calculator on your own site, and see how the numbers are checked against their sources.


Frequently Asked Questions

What do these tools cost?

Nothing. Every tool is open to anyone: no login, no email gate, no ads. We build these tools because they help trade contractors do better work, and we think that earns trust. Accuracy and usefulness are the whole point; the site supports itself.

How accurate are the electrical calculators?

The NEC calculators compute from the NEC 2023 (NFPA 70-2023) and name the article and table each step used, for example 310.16 ampacity, 250.122 grounding and Chapter 9 conduit fill. Rough-in by room takes the 2020, 2023 or 2026 edition, the outdoor HVAC GFCI answer reads the 2020, 2023 or 2026 text, whichever your state enforces, and points an older edition to its own section, and the 2026 changes page reads the 2023 and 2026 books side by side. Each edition is read from its own book. The bending tools compute from bender charts and geometry, with the bend radius from NEC Chapter 9 Table 2. Check your local jurisdiction for adopted edition: some states already enforce the newer 2026 NEC, namely Massachusetts (since April 24, 2026), Maine (since July 1, 2026), North Dakota (since July 1, 2026), Colorado (since August 1, 2026), Minnesota (since August 17, 2026), Texas (since September 1, 2026), Arkansas (since September 3, 2026) and Oregon (since October 1, 2026), and some still enforce older editions, back to the 2008 NEC in Indiana. Each state's edition, with its source and the date it is true as of (October 7, 2026 to November 11, 2026), is on our NEC adoption table at https://www.intrysys.com/tools/electrical/nec-adoption-by-state.

Do I need to create an account to use these tools?

No. Every tool works instantly in your browser with zero signup. You can bookmark results or use the share button to generate a link with your inputs pre-filled.

Pick a calculator and get to work.

Wire sizing, conduit bends, BTU loads, pricing math: every tool cites its source so you can check the numbers yourself. The tools never ask for a login or an email.

Intry Pro files what these tools work out onto the unit or panel, as you work. See Intry Pro ›