Equipment lifespan

How much longer will it last? AC, heat pump and gas furnace lifespan by age

Enter the type and its age, or the year it was built. The page works out, for the national stock of that type, how long the ones that reached that age went on: when half of them were out of use, and what share were still in use five years later. It is read off a published survival curve, with the study's own conditions beside it, and it is not a forecast for your unit. The study, and what it says it assumes, are in the source receipt below.

The study's median life, by type

The age at which half of the national stock of each type was out of use, on the curve fitted in the study. The figure for a unit that has already reached a given age is the one the calculator above works out.

Central air conditioner18.0 years (Table 2)
Heat pump14.6 years (Table 3)
Gas furnace22.6 years (Table 4)

Questions

How long do AC units last?

There is no one life for one unit. In the national stock, on the survival curve Lawrence Berkeley National Laboratory published in October 2011, half of all central air conditioners were out of use by 18.0 years, and the study attaches a condition to that figure: "it was assumed that 95% of the appliance stock is in residential units and, thus, is captured by RECS and AHS. If it was assumed that 100% of the stock was in residential applications, the median lifetime would decrease to 16.5 years; if it was assumed that 90% of the stock is in housing units, the median lifetime would increase to 19.7 years." For how long the ones that reached a given age went on, enter the age on this page.

How long do heat pumps and furnaces last?

On the same study's curves, half of all heat pumps were out of use by 14.6 years and half of all gas furnaces by 22.6 years. For heat pumps the study says: "No single realistic survival function easily fits the shipment and stock history for residential heat pumps." and the input data was restricted to AHS and RECS only from 2001 to 2007 (the most recent data available). Its furnace curve is for gas furnaces only.

Should I replace my old AC?

This page does not say. It gives how long that type of equipment lasted from a given age across the national stock, which is a population figure and not a forecast for any one unit. Repair or replace is not worked out here.

Why does this page not show one number in its title?

Because the figure that matters depends on the age. Of the air conditioners that reached a given age, how long half of them went on is a figure that changes with the age, and this page works it out for the age you enter.