HVAC Calculators

Free HVAC Calculators

Organized by the job: sizing equipment, ductwork and airflow, charging and diagnostics, the A2L changeover, and decoding a nameplate. Under each job the calculators, charts, and guides are labeled so you grab the right kind fast. Every number cites its source.


Sizing the equipment

More calculators

Ductwork & airflow

The air side of the job: size the duct from CFM, convert a shape, and set the friction rate the duct sizer runs on.


Charge, test & diagnose

More calculators: by refrigerant

The A2L changeover (R-454B & R-32)

EPA's Technology Transitions rule moved new residential air conditioners and heat pumps from R-410A to A2L refrigerants such as R-454B and R-32 from 2025. Reuse a line set, stay under the charge limit, meet the leak rule, and know how the two compare. The rule, its dates and the Federal Register documents behind it.

More calculators

Chillers and the refrigerant rules (leak repair, purge, blends, retrofit, approach)

The AIM Act leak repair rule and the Technology Transitions limits, read against the machine in front of you: the federal leak rate and every deadline it triggers, a purge log read against Trane's own bands, whether a blend can be topped off, which refrigerants EPA lists for an R-134a centrifugal retrofit, and the condenser approach graded against the machine's own commissioning record.


Converting to a heat pump? Switchover and the gas left behind

The gas-furnace-to-heat-pump changeout spans the whole job: what the heat pump can deliver in the cold, when to hand a cold hour back to the furnace, and the combustion air the water heater still left in the space now needs on its own.

Sizing the panel for the new heat pump and its backup?Can My Panel Handle Itchecks the electrical side of the conversion.

More calculators

What am I looking at? Decode the nameplate

Age from the serial and tonnage from the model, before you quote the job or pull a part.

More calculators

The circuit your equipment needs

Sized the equipment? Cross over to the electrical side for the breaker, wire, and panel capacity it needs.


Frequently Asked Questions

What do these HVAC calculators cost?

Nothing: no login, no email gate, no ads. We build these tools because they help trade contractors do better work. If a number is wrong we want to hear about it. Accuracy is the whole point.

How accurate is the BTU calculator?

The BTU calculator runs ACCA Manual J's abridged method on our server at the ASHRAE weather station nearest your ZIP code, on DOE's 2021 reference house plan with your answers, and lists the answers it does not ask beside the load. Where your house differs from those assumptions its load differs, and where Manual J's printed tables do not reach a station's cooling conditions at the daily range class you set, it gives no cooling load rather than a guess and says whether another class computes there. It is a whole-house block load, not the room-by-room Manual J a permit or an equipment selection needs.

Which refrigerants does the superheat calculator support?

The calculator includes R-410A, R-407C (with zeotropic glide handling), R-134a, R-404A, R-22 (legacy), R-454B (Puron Advance), R-32, R-407A, R-448A, R-449A, and R-290 (propane). PT tables are read from published charts and reference data (National Refrigerants, Hudson Technologies, Chemours, Arkema, Weitron, CoolProp), and every table is cross-checked against at least one other published table, with cross-checks that resolve to the same equation of state marked as consistency checks rather than independent confirmation.

More math off your plate.

Size the system with the BTU calculator, verify the charge with superheat and subcooling, then make sure the invoice actually covers your overhead.