NEC Wire Sizing

What Size Wire for an Electric Cooktop?

The breaker, copper and aluminum wire, and ground for a typical electric cooktop circuit, with the NEC basis and the nameplate caveats that actually decide it.

Quick answer: An electric cooktop typically needs a 40A / 240V circuit with #8 copper (or #6 aluminum) wire and a #10 copper ground.

Electric Cooktop Circuit Spec

Typical branch circuit for an electric cooktop (nameplate rating)
Voltage240V
Breaker40A
Copper wire#8
Aluminum wire#6
Equipment ground (Cu)#10

Cooktops range from 30A to 50A depending on the number and size of elements. A standard four-burner cooktop is commonly on a 40A circuit; size to the nameplate. Wire sized at NEC Table 310.16 (copper lead at the 60°C column for NM-B); ground per NEC Table 250.122. The appliance nameplate lists the exact minimum circuit and maximum breaker; it always governs over a typical value.


Long Run? Size It Exactly

For a long run where voltage drop matters, or a nameplate that differs from the typical value, enter your exact load, distance, and conditions.

Loading calculator...

Frequently Asked Questions

What size wire do I need for an electric cooktop?

An electric cooktop typically uses a 40A / 240V circuit, which calls for #8 copper (or #6 aluminum) conductors and a #10 copper equipment ground per NEC Table 250.122. Cooktops range from 30A to 50A depending on the number and size of elements. A standard four-burner cooktop is commonly on a 40A circuit; size to the nameplate.

What breaker size for an electric cooktop?

A 40A double-pole breaker. The #8 copper conductors are matched to that 40A rating. Always confirm against the appliance nameplate, which lists the exact minimum circuit and maximum breaker.

Can I use aluminum wire for an electric cooktop?

Yes. For the 40A circuit, aluminum needs #6 (versus #8 copper) at the 75C column. Aluminum is common on larger circuits and services to save cost; apply antioxidant to the terminations, torque to the listed spec, and remember aluminum drops slightly more voltage on long runs.