How Many Amps Does a Window Air Conditioner Use?

The running amps a window air conditioner draws, the watts-to-amps math behind it, and the branch circuit this page shows it on, with what the code permits.

Quick answer: Frigidaire's specification sheet for the FFRE123ZA1 12,000 BTU window air conditioner lists Amps (Cool) "10.3", Voltage Rating "115V 60Hz", Watts (Cool) "1000" and Plug Type "LCDI 5-15P": 10.3 amps at 115V, the current its maker prints. The motor briefly surges higher at startup. This page shows it on a dedicated 20A / 120V circuit. A cord-and-plug room air conditioner may draw up to 80 percent of a circuit it has to itself (NEC 440.62(B)) and up to 50 percent of one that also supplies lights, other appliances or general-use receptacles (440.62(C)). The code grades the current marked on the unit's nameplate: the 10.3 amps on this page are the current the Frigidaire FFRE123ZA1's maker prints, so check your own unit's nameplate amps in the circuit check. Where its nameplate prints amps, those govern; watts ÷ volts is the current only of a heating element. The 115 V on Frigidaire FFRE123ZA1's sheet is the maker's rating for a unit that sits on a 120 V circuit, and NEC 220.5(A) calculates branch-circuit loads at the nominal 120 volts, so the circuit check opens at 120 V.

Will a window air conditioner Run on Your Circuit?


Window Air Conditioner Amps by Size

Watts and amps for each row as its document prints them; the volts are a row's own printed voltage where the row carries one and otherwise this page's 115 V, which that row's document may not print, and a row whose document prints no amps shows its watts over those volts

Swipe the table sideways to see the rest of its columns. →

Window Air ConditionerWattsVoltsAmps
5,200 BTU Frigidaire FFRE053ZA1420 W115V3.7 A
8,000 BTU Frigidaire FFRE083ZA1660 W115V6.6 A
10,000 BTU Frigidaire FFRE103ZA1840 W115V8.9 A
12,000 BTU Frigidaire FFRE123ZA11,000 W115V10.3 A

Each row's figures as its document prints them, not code data; your appliance's nameplate governs. Motor loads also draw a brief startup surge above their running current.

Window Air Conditioner Circuit

Figures for the Frigidaire FFRE123ZA1 and the circuit shown for a window air conditioner (NEC 440.62, 210.23(B))

Swipe the table sideways to see the rest of its columns. →

Watts (Frigidaire FFRE123ZA1)1,000 W
Voltage115V
Running amps10.3 A
Startup surgeYes (motor)
Circuit shown20A / 120V dedicated

Frigidaire's FFRE sheets, all rated 115V 60Hz, list in cooling: the 5,200 BTU FFRE053ZA1 at 3.7 amps and 420 watts, the 8,000 BTU FFRE083ZA1 at 6.6 amps and 660 watts, the 10,000 BTU FFRE103ZA1 at 8.9 amps and 840 watts, and the 12,000 BTU FFRE123ZA1 at 10.3 amps and 1000 watts, plus a brief compressor surge. The printed amps are the current to grade a circuit on. Small units share a 15A or 20A circuit; a large 120V unit wants a dedicated 20A circuit, and the biggest models are 240V. The unit's plug type tells you which. The amps here are the current the Frigidaire FFRE123ZA1's maker prints; your own unit's nameplate amps are its current; a continuous load (3 hours or more) may use at most 80% of the breaker, the same rule as rating the breaker at 125% of it (NEC 210.20(A)). The nameplate lists the exact draw and governs over the figure on this page.

Source: Frigidaire FFRE123ZA1, 12,000 BTU Window-Mounted Room Air Conditioner, product specifications (version 03/20), read 2026-11-12.

Adding this on a new circuit? Check whether your panel can handle it (the NEC 220.87 service check), or size the breaker for the load.


Convert Watts to Amps

Watts divided by volts is the current only of a heating element, so for a window air conditioner the converter below gives a rough figure, not its current. The amps its nameplate prints are its current; where it prints only watts, the maker's documentation or a measured current gives the amps. The power factor field changes the conversion only where you know the unit's power factor.

The code sections this page cites are named in the source receipt.


Frequently Asked Questions

How many amps does a window air conditioner use?

Frigidaire's specification sheet for the FFRE123ZA1 12,000 BTU window air conditioner lists Amps (Cool) "10.3", Voltage Rating "115V 60Hz", Watts (Cool) "1000" and Plug Type "LCDI 5-15P". That is 10.3 amps at 115 volts, the current its maker prints. Because it is a motor load, it surges to several times that for a moment at startup. For your unit's own draw, read the amperes on its nameplate where it prints them: watts divided by volts is the current only of a heating element. Frigidaire's FFRE sheets, all rated 115V 60Hz, list in cooling: the 5,200 BTU FFRE053ZA1 at 3.7 amps and 420 watts, the 8,000 BTU FFRE083ZA1 at 6.6 amps and 660 watts, the 10,000 BTU FFRE103ZA1 at 8.9 amps and 840 watts, and the 12,000 BTU FFRE123ZA1 at 10.3 amps and 1000 watts, plus a brief compressor surge. The printed amps are the current to grade a circuit on. Small units share a 15A or 20A circuit; a large 120V unit wants a dedicated 20A circuit, and the biggest models are 240V. The unit's plug type tells you which.

What size breaker for a window air conditioner?

This page shows a window air conditioner on a dedicated 20A / 120V circuit. A cord-and-plug room air conditioner may draw up to 80 percent of a circuit it has to itself (NEC 440.62(B)) and up to 50 percent of one that also supplies lights, other appliances or general-use receptacles (440.62(C)). The code grades the current marked on the unit's nameplate: the 10.3 amps on this page are the current the Frigidaire FFRE123ZA1's maker prints, so check your own unit's nameplate amps in the circuit check. NEC 440.62(B) holds a cord-and-plug room air conditioner on its own circuit to 80 percent of it, 16A on that 20A circuit, graded on the current marked on its nameplate: the Frigidaire FFRE123ZA1's maker prints 10.3 amps.

How do I calculate the amps a window air conditioner draws?

Read the amperes printed on its nameplate. Watts divided by volts is the current only of a heating element with no motor, fan, pump, compressor or electronics, so for a window air conditioner the nameplate amps are the figure to use. The figure on this page, 10.3 amps, is the current the Frigidaire FFRE123ZA1's maker prints; your own unit's nameplate prints its own. Add a startup surge of several times that for a fraction of a second on the motor. Your appliance's nameplate governs over the figure on this page.

Does the size of a window air conditioner change the amps?

Yes. By the figures each row's document prints, 5,200 BTU Frigidaire FFRE053ZA1 at 420 W is 3.7 amps at 115 V, and 12,000 BTU Frigidaire FFRE123ZA1 at 1,000 W is 10.3 amps at 115 V. See the table above. The rating on the nameplate is the number to size the circuit to.

How many amps does a window ac use?

Same answer: window ac is another name for a window air conditioner. It draws 10.3 amps at 115V, the current the Frigidaire FFRE123ZA1's maker prints,shown here on a dedicated 20A / 120V circuit. Frigidaire's FFRE sheets, all rated 115V 60Hz, list in cooling: the 5,200 BTU FFRE053ZA1 at 3.7 amps and 420 watts, the 8,000 BTU FFRE083ZA1 at 6.6 amps and 660 watts, the 10,000 BTU FFRE103ZA1 at 8.9 amps and 840 watts, and the 12,000 BTU FFRE123ZA1 at 10.3 amps and 1000 watts, plus a brief compressor surge. The printed amps are the current to grade a circuit on. Small units share a 15A or 20A circuit; a large 120V unit wants a dedicated 20A circuit, and the biggest models are 240V. The unit's plug type tells you which.


How Many Amps Do Other Appliances Use?