Water Heater Age Decoder

Richmond water heater age from the serial number

The manufacture date and age of a Richmond water heater, read character by character from Rheem's own date-code document.


How a Richmond Serial Carries the Date

On the older digits-first label the serial is ten characters: two digits of month, two digits of year, a plant line code letter, then a five digit sequence. From April 2012, plant by plant, the label changed to a plant letter followed by two digits of week, two digits of year and the sequence, with an optional conversion letter at the end. The rating label pictured in the bulletin carries a product prefix in front of the plant letter, so the tool reads the plant letter as the last letter before the digits.

The Richmond formats this tool reads

Swipe the table sideways to see the rest of its columns. →

FormatLayoutWhen
Rheem / Ruud / Richmond, older digits-first rating labelMM YY + plant line code letter + 5 digit sequence (10 characters)The format used until that plant's Oracle changeover, which began April 2012 and ran plant by plant
Rheem / Ruud / Richmond, 2012-onward rating labelOptional product prefix + plant letter + WW + YY + 5 digit sequence (+ conversion suffix)April 2012 onward, per plant as each migrated to Oracle

Worked Examples

0912D01234

This is the example on page 1 of bulletin 1207, printed there as 09 | 12 | D | 01234. The tool reads it as September 2012, about 14 years old in 2026.

M141209135

This is a worked example on page 2 of bulletin 1207. The tool reads it as week 14 of 2012, about 14 years old in 2026.

Each line above is the decoder's own answer for that serial, worked out in 2026.


Frequently Asked Questions

How do I tell how old my Richmond water heater is from the serial number?

On the older digits-first label the serial is ten characters: two digits of month, two digits of year, a plant line code letter, then a five digit sequence. From April 2012, plant by plant, the label changed to a plant letter followed by two digits of week, two digits of year and the sequence, with an optional conversion letter at the end. The rating label pictured in the bulletin carries a product prefix in front of the plant letter, so the tool reads the plant letter as the last letter before the digits. Enter the serial in the decoder on this page and it shows the date, the age and which characters it read, or says why this serial cannot be resolved to one date.

Which documents is the Richmond decode read from?

"How to Locate and Read Rheem/Ruud/Richmond Serial Numbers", published by Rheem; Rheem's copy is kept on the Rheem document CDN (cdn.globalimageserver.com). The same bulletin covers Rheem and Ruud, so their serials read the same way.

How do I check the warranty on a Richmond water heater?

Richmond's own warranty verification is at richmond.registermyunit.com, linked from www.richmondwaterheaters.com. Richmond's own site lists it under Warranty as "Verify". Its form asks for the serial, the homeowner's last name and the homeowner's state. This tool does not read the maker's records, so it cannot show this tank's warranty or whether it was registered.


Related