Water Heater Age Decoder

Rheem water heater age from the serial number

The manufacture date and age of a Rheem water heater, read character by character from Rheem's own date-code document.


How a Rheem Serial Carries the Date

On the older digits-first label the serial is ten characters: two digits of month, two digits of year, a plant line code letter, then a five digit sequence. From April 2012, plant by plant, the label changed to a plant letter followed by two digits of week, two digits of year and the sequence, with an optional conversion letter at the end. The rating label pictured in the bulletin carries a product prefix in front of the plant letter, so the tool reads the plant letter as the last letter before the digits.

The Rheem formats this tool reads

Swipe the table sideways to see the rest of its columns. →

FormatLayoutWhen
Rheem / Ruud / Richmond, older digits-first rating labelMM YY + plant line code letter + 5 digit sequence (10 characters)The format used until that plant's Oracle changeover, which began April 2012 and ran plant by plant
Rheem / Ruud / Richmond, 2012-onward rating labelOptional product prefix + plant letter + WW + YY + 5 digit sequence (+ conversion suffix)April 2012 onward, per plant as each migrated to Oracle

Worked Examples

0912D01234

This is the example on page 1 of bulletin 1207, printed there as 09 | 12 | D | 01234. The tool reads it as September 2012, about 14 years old in 2026.

M141209135

This is a worked example on page 2 of bulletin 1207. The tool reads it as week 14 of 2012, about 14 years old in 2026.

RHLNQ231299996

This is the serial on the Rheem Fury rating label pictured in bulletin 1207. The tool reads it as week 23 of 2012, about 14 years old in 2026.

Each line above is the decoder's own answer for that serial, worked out in 2026.

Rheem serials from public records, dated

Each serial in the record tables below is listed under Rheem in a public body's own equipment record, beside a year. “The decoder reads” is what the water heater decoder on this page returns for it, worked out when this page was built in 2026.

Winter Park, Florida: 8 serials; the decoder reads 6 of 8 as the year listed and does not decode 2

The records: Azalea lane recreation center energy audit 2023-09, City hall energy audit 2023-09, City operations energy audit 2023-09, East treatment plant energy audit 2023-09, Wellness place energy audit 2023-09.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
R0897D02637Water Heater - 30 Gallons1997No readingNot decoded
1199B19852Electric Water Heater - 30 Gallon1999November 1999Same year
RH0904B35187Water Heater - 50 Gallons2004No readingNot decoded
0905E00128Water Heater - 85 Gallons2005September 2005Same year
A371406560Electric Water Heater - 42 Gallon2014Week 37 of 2014Same year
Q041621742Electric Water Heater - 40 Gallon2016Week 4 of 2016Same year
Q051707573Electric Water Heater - 50 Gallon2017Week 5 of 2017Same year
Q052122174Electric Water Heater - 50 Gallon2021Week 5 of 2021Same year

Frequently Asked Questions

How do I tell how old my Rheem water heater is from the serial number?

On the older digits-first label the serial is ten characters: two digits of month, two digits of year, a plant line code letter, then a five digit sequence. From April 2012, plant by plant, the label changed to a plant letter followed by two digits of week, two digits of year and the sequence, with an optional conversion letter at the end. The rating label pictured in the bulletin carries a product prefix in front of the plant letter, so the tool reads the plant letter as the last letter before the digits. Enter the serial in the decoder on this page and it shows the date, the age and which characters it read, or says why this serial cannot be resolved to one date.

Which documents is the Rheem decode read from?

"How to Locate and Read Rheem/Ruud/Richmond Serial Numbers", published by Rheem; Rheem's copy is kept on the Rheem document CDN (cdn.globalimageserver.com). The same bulletin covers Ruud and Richmond, so their serials read the same way.

How do I check the warranty on a Rheem water heater?

Rheem's own warranty verification is at rheem.registermyunit.com, linked from www.rheem.com. Rheem's warranties page says: "If you’ve already registered your Rheem product and would like to verify your warranty terms and coverage, your serial number is required." Its form asks for the serial, the homeowner's last name and the homeowner's state. This tool does not read the maker's records, so it cannot show this tank's warranty or whether it was registered.