Water Heater Age Decoder

Bradford White water heater age from the serial number

The manufacture date and age of a Bradford White water heater, read character by character from Bradford White's own date-code documents. Where a serial genuinely carries two years, both are shown and no age is given.


How a Bradford White Serial Carries the Date

The first character of the serial is the year letter and the second is the month letter; the rest is a production number. Bradford White's year column uses 20 letters, so every letter comes round again every 20 years, and the letter alone cannot say which of those years it means. Bradford White documents a second fact in the same serial: the production number is 7 digits before December 2007 and 8 digits after. The tool applies it, which leaves at most one year except for a 7-digit serial under year letter A, B, C or D, where two years still fit and the tool shows both and no age. A serial starting OA is a batch Bradford White documents directly: "Due to a computer error there were some OA serial water heaters manufactured. They were built in January of 1997."

The Bradford White formats this tool reads

Swipe the table sideways to see the rest of its columns. →

FormatLayoutWhen
Bradford White year letter + month letterYear letter + month letter + 7 or 8 digit production number1984 to present
Bradford White OA computer-error batchOA + production numberJanuary 1997 only

Bradford White year letters, and the years this tool can return for each, as of 2026

Swipe the table sideways to see the rest of its columns. →

LetterPossible yearsLetterPossible years
A1984, 2004, 2024L1994, 2014
B1985, 2005, 2025M1995, 2015
C1986, 2006, 2026N1996, 2016
D1987, 2007P1997, 2017
E1988, 2008S1998, 2018
F1989, 2009T1999, 2019
G1990, 2010W2000, 2020
H1991, 2011X2001, 2021
J1992, 2012Y2002, 2022
K1993, 2013Z2003, 2023

Worked Examples

MG12345678

An example serial in this format. The tool reads it as July 2015, about 11 years old in 2026.

DA1234567

An example serial in this format. It reads as January 1987 or January 2007, and the tool gives no age: both years fit everything the serial says, and the rating plate settles it.

OA1234567

An example serial in this format. The tool reads it as January 1997, about 29 years old in 2026.

Each line above is the decoder's own answer for that serial, worked out in 2026.


Frequently Asked Questions

How do I tell how old my Bradford White water heater is from the serial number?

The first character of the serial is the year letter and the second is the month letter; the rest is a production number. Bradford White's year column uses 20 letters, so every letter comes round again every 20 years, and the letter alone cannot say which of those years it means. Bradford White documents a second fact in the same serial: the production number is 7 digits before December 2007 and 8 digits after. The tool applies it, which leaves at most one year except for a 7-digit serial under year letter A, B, C or D, where two years still fit and the tool shows both and no age. A serial starting OA is a batch Bradford White documents directly: "Due to a computer error there were some OA serial water heaters manufactured. They were built in January of 1997." Enter the serial in the decoder on this page and it shows the date, the age and which characters it read, or says why this serial cannot be resolved to one date.

Why can the tool show two dates for a Bradford White serial?

Because the serial carries both. The year letter repeats every 20 years, and where the production number's length does not rule one out, two real years remain. Picking one would be a guess, so the tool shows both and no age.

Which documents is the Bradford White decode read from?

"My Water Heater (Determine The Age of My Water Heater)", "Determining The Age Of A Water Heater" and "How to read the serial number date code reference chart?", published by Bradford White and Bradford White For The Pro.

How do I check the warranty on a Bradford White water heater?

Bradford White's own warranty check is at warrantycenter.bradfordwhite.com, linked from www.bradfordwhite.com. Bradford White's Warranty Center says: "enter your water heater's serial number. The water heater information will include the warranty length and expiration date." Of the same box it says the information "will include the manufacture date of your water heater." This tool does not read the maker's records, so it cannot show this tank's warranty or whether it was registered.