HVAC Serial Number Lookup
York Serial Number Lookup: AC and Furnace Age
York is part of the York / Johnson Controls family, alongside Coleman, Fraser-Johnston, Guardian, Luxaire. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.
Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.
7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. Some of the formats on this page are read from a document a distributor of the manufacturer publishes as its own, which is not the manufacturer's; the others rest on secondary references, and each row below says which. A date stamped or printed on the data plate always outranks a serial decode.
York furnace not heating?
Its stop checks come first, then what its light or code means, on furnace codes for York. Type what the furnace shows and it opens there with the brand filled in.
York Serial Number Formats
| Format | Era | Example | Confidence |
|---|---|---|---|
| Letter + digit + letter + digit + 6-digit sequence; the two digits read together are the year, the second letter is the month (A to N, skipping I and J)"YORK Serial Number Information (production after 10/6/2004)", published by US Air Conditioning Distributors, a York distributor, is held and states this layout; the sheet does not print its author. No manufacturer document for this layout is held. The sheet agrees with 3 secondary references. | October 2004 to present | W1G7123456 = July 2017, Wichita KS plant | high |
| 4 letters + 6 digits; second letter = month, third letter = year on a 21-year cycleCross-checked across 3 secondary references, not a manufacturer document. | 1971 to October 2004 | YHFM321456 = August 1976 or August 1997 (year letter F repeats) | high |
Worked Example: York W1G7123456
Expected decode: July 2017, Wichita KS plant. Character by character:
W = plant code (Wichita KS)
1 and 7 = year digits read together: 2017
G = July (month letters A to N, I and J skipped)
123456 = production sequence
York serials from public records, dated
Each serial in the record tables below is listed under York in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026. Serials on government surplus listings, a weaker check, follow the records.
The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.
Myrtle Beach, South Carolina: 7 serials; the decoder reads 2 of 7 as the year listed, shows it among other years for 4 and does not decode 1
The record: CMB HVAC Inventory and ICE Machine Inventory final.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| WKKM010495 | Not listed per unit | 2001 | September 2001 or September 1980 | Same year, one of the years shown |
| WBMM009584 | Not listed per unit | 2003 | February 2003 or February 1982 | Same year, one of the years shown |
| NENM055949 | Not listed per unit | 2004 | May 2004 or May 1983 | Same year, one of the years shown |
| NENN020973 | Not listed per unit | 2004 | May 2004 or May 1983 | Same year, one of the years shown |
| WOH5826663 | Not listed per unit | 2005 | No reading | Not decoded |
| N0G6611984 | Not listed per unit | 2006 | July 2006 | Same year |
| N1L6088148 | Not listed per unit | 2016 | October 2016 | Same year |
Wayne Township, New Jersey: 4 serials; the decoder reads 1 of 4 as the year listed and shows it among other years for 3
The record: Wayne, Township of LGEA 07282014 FINAL Redacted.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| NMLM129416 | Not listed per unit | 2002 | November 2002 or November 1981 | Same year, one of the years shown |
| NMLM129418 | Not listed per unit | 2002 | November 2002 or November 1981 | Same year, one of the years shown |
| NFMM067619 | Not listed per unit | 2003 | June 2003 or June 1982 | Same year, one of the years shown |
| W1H3979102 | Not listed per unit | 2013 | August 2013 | Same year |
York serials on government surplus listings
On these, the year is one a seller entered in the listing's own year field, not a year the manufacturer or a public record states, so it is a weaker check than a public record. “The decoder reads” is what the serial lookup on this page returns for the serial, worked out when this page was built in 2026. The listings are not named here, because a seller's entry is not a citation. 2 serials; the decoder reads 0 of 2 as the year listed and does not decode 1.
| Serial | Equipment, as listed | Year a seller entered | The decoder reads | Against the year listed |
|---|---|---|---|---|
| 2DXM010954 | 300-ton air-cooled chiller | 2011 | No reading | Not decoded |
| N1N8424134 | ZEO48H12B4A1AAA1A1 rooftop unit | 2019 | December 2018 | A different year |
Reading York model numbers
The York lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the tonnage decoder.
| Line | Example model | What the tonnage decoder reads | Document |
|---|---|---|---|
| York Solution XT air handler | XTI-048X075-DCMK046A | An air handler: identified, no size is read | Form 102.20-NOM1 (909) |
| York Champion D1EB single package air conditioner (50 Hz) | D1EB036A50 | A packaged unit: 3 tons (36,000 BTU/h) | 036-21686-001-A-0306 |
| York Champion/Affinity D2EB single package air conditioner | D2EB036A06 | A packaged unit: 3 tons (36,000 BTU/h) | 174065-YIM-A-0206, 360101-XTG-B-0508 |
| York Latitude AHR air handler | AHR42A3A | An air handler: identified; its maker's document prints no model number legend, so no size is read | PUBL-6755-A-0711 |
| York E1RC/E2RC 12 SEER heat pump outdoor unit | E1RC036S25 | The outdoor unit of a York E1RC/E2RC split system heat pump: identified; its maker's document prints no model number legend, so no size is read | 035-18774-001 Rev. A (0903), 035-20525-001 Rev. B (0306) |
| York YLAA air-cooled scroll chiller | YLAA0125 | An air-cooled scroll chiller: large commercial equipment, outside this tool's range, so no tonnage is read | Form 150.72-EG6 (1023) |
| York YCAL Millennium air-cooled scroll chiller | YCAL0014 | An air-cooled scroll chiller: large commercial equipment, outside this tool's range, so no tonnage is read | FORM 150.62-EG1 (406) |
| York Affinity D1EB single package air conditioner (60 Hz) | D1EB036A25 | A packaged unit: 3 tons (36,000 BTU/h) | 360102-YTG-A-0108 |
| York TCGD 13 SEER split system air conditioner | TCGD36S41S1 | The outdoor unit of a split system air conditioner: identified; its maker's document prints no model number legend, so no size is read | 359315-YTG-E-0109 |
| York YCJF 14.5 SEER split system air conditioner | YCJF48S41S1 | The outdoor unit of a split system air conditioner: identified; its maker's document prints no model number legend, so no size is read | 413437-YTG-C-0908 |
CPSC recall notices naming York
Hazard, in the notice's words: “Because of inadequate gluing, the insulation surrounding the heat exchanger can separate from the cabinet wall of the furnace, and fall onto the heat exchanger. This could cause surrounding combustible material and drywall to catch on fire, which has the potential to cause burn injuries and deaths.”
Hazard, in the notice's words: “Heat exchangers in the furnace can crack.”
Hazard, in the notice's words: “Parts of the furnace and vent system may fail prematurely. Failure of vent components could allow potentially hazardous carbon monoxide (CO) gas to leak into the home.”
Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.
York Refrigerant Timeline
| Manufacture year | Refrigerant the years point to | Notes |
|---|---|---|
| through 2005 | R-22 | Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22. |
| 2006 to 2009 | R-22 or R-410A | Overlap window as JCI lines transitioned to R-410A. |
| 2010 to 2024 | R-410A | From January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024. |
| 2025 and later | R-454B | JCI chose R-454B for York, Luxaire, Coleman, Fraser-Johnston, and Guardian ducted residential, with production from 2024-2025 onward. |
The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.
York Warranty Terms
York warranty lookup
The maker's own page: York's own warranty tools, at www.yorknow.com. The page reads: "Lookup the status of a registered and installed piece of equipment by entering the serial number below." This page reads no maker's records and cannot show whether a unit was registered. Open York's own warranty tools
What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the York warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.
3 U.S. Consumer Product Safety Commission recall notices this tool matches name York equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
The York warranty terms held here
10 York family air conditioner and heat pump warranty certificate editions covering York are held here, from 813196-UUM-E-0314 (March 2014, by its form suffix) to 6783352-UUM-A-0626 (June 2026, by its form suffix). Every one prints a base parts term of 5 years for its residential row. Each gives 10 years if registered within 90 days (813196-UUM-E-0314 to 6783352-UUM-A-0626), except on the models an edition excepts. How the term starts changed between editions: first at registration, or at shipment when no registration is on record; later at installation only (no start counted from manufacture is printed). Every one ties its terms to the original owner; 6783352-UUM-A-0626 (June 2026, by its form suffix) prints: "This Limited Warranty extends only to the Buyer and is non-transferable." It also prints: "In some states or provinces, the limited warranty is available at no charge to a subsequent owner/homeowner if the product has been used solely for the original residential application. To determine whether your limited warranty is transferrable to a subsequent homeowner (subject to a transfer fee) please contact Manufacturer at 1-877-874-7378." 813196-UUM-E-0314, 1183508-UUM-L-0818, 1183508-UUM-O-0121 print a lifetime compressor term with its own conditions; no compressor end is worked out here. None pays for labour.
Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. Only the maker's records show whether a unit was registered.
Source: the maker's own limited warranty certificates, each identified by the part number printed on it; the serial result names the edition each term comes from, and the statute where a line quotes one.
Frequently Asked Questions
How old is my York unit?
Decode the serial number from the data plate. The dominant York format (October 2004 to present) is: Letter + digit + letter + digit + 6-digit sequence; the two digits read together are the year, the second letter is the month (A to N, skipping I and J). Example: W1G7123456 decodes to July 2017, Wichita KS plant. Subtract the decoded year from the current year for the age.
Which brands share the York serial number format?
York is part of the York / Johnson Controls family, alongside Coleman, Fraser-Johnston, Guardian, and Luxaire. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.
Has the York serial decode been checked against serials somebody else dated?
York/JCI modern (letter-digit-letter-digit): Read against 6 serials where a public body's own equipment schedule prints a year beside the serial (Myrtle Beach, South Carolina; Wayne Township, New Jersey; the year sits under a column headed Year on 4, and in a row labelled Year Manufactured on 2, 4 of which the document does not define): 5 matched the reading shown first, 1 did not match any reading (the published year ran earlier than this tool's reading); and 1 serial where a seller entered a year in the listing's own year field on a government surplus listing for the serial (government surplus auction listings), ZEO48H12B4A1AAA1A1 rooftop unit: 1 did not match any reading (the published year ran later than this tool's reading); a seller's year is shown here for the record and is not counted toward this format's check.
York/JCI legacy (4 letters + 6 digits): Checked against 2 serials whose date a recall notice published by someone other than us states (CPSC recall notice 00-003), Diamond 80 downflow mid-efficiency furnaces. The date this tool reads first was consistent with the published window on all 2. Also read against 7 serials where a public body's own equipment schedule prints a year beside the serial (Myrtle Beach, South Carolina; Wayne Township, New Jersey; the year sits under a column headed Year on 4, and in a row labelled Year Manufactured on 3, 4 of which the document does not define): 7 matched the reading shown first.
Across the York formats on this page, 2 serials with a date published outside this tool produced no reading at all (Myrtle Beach, South Carolina; government surplus auction listings). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.
Where someone outside this tool wrote down a different year for a unit, that year is shown here rather than dropped. It is that publisher's record for the unit, and a schedule or a listing can carry a replacement, system or lot year rather than the build year. The MFG DATE on the unit's data plate is the build date.
What refrigerant does a York unit use?
By manufacture year: through 2005: R-22; 2006 to 2009: R-22 or R-410A; 2010 to 2024: R-410A; 2025 and later: R-454B. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.
How do I look up my York warranty?
The maker's own page: York's own warranty tools, at www.yorknow.com. The page reads: "Lookup the status of a registered and installed piece of equipment by entering the serial number below." This page reads no maker's records and cannot show whether a unit was registered. What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the York warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit. 3 U.S. Consumer Product Safety Commission recall notices this tool matches name York equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
Is my York unit still under warranty?
10 York family air conditioner and heat pump warranty certificate editions covering York are held here, from 813196-UUM-E-0314 (March 2014, by its form suffix) to 6783352-UUM-A-0626 (June 2026, by its form suffix). Every one prints a base parts term of 5 years for its residential row. Each gives 10 years if registered within 90 days (813196-UUM-E-0314 to 6783352-UUM-A-0626), except on the models an edition excepts. How the term starts changed between editions: first at registration, or at shipment when no registration is on record; later at installation only (no start counted from manufacture is printed). Every one ties its terms to the original owner; 6783352-UUM-A-0626 (June 2026, by its form suffix) prints: "This Limited Warranty extends only to the Buyer and is non-transferable." It also prints: "In some states or provinces, the limited warranty is available at no charge to a subsequent owner/homeowner if the product has been used solely for the original residential application. To determine whether your limited warranty is transferrable to a subsequent homeowner (subject to a transfer fee) please contact Manufacturer at 1-877-874-7378." 813196-UUM-E-0314, 1183508-UUM-L-0818, 1183508-UUM-O-0121 print a lifetime compressor term with its own conditions; no compressor end is worked out here. None pays for labour. Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. Only the maker's records show whether a unit was registered.
Why do some York serial numbers refuse to decode?
A York serial is declined in two cases. It matches none of the 2 York formats this tool documents, or it has the shape that format expects and the values it reads are impossible: a week outside 1 to 53, a month outside 1 to 12, or a year outside 1955 to 2026. Either way the tool states no date rather than guessing one, and says which of the two happened. The tool also identifies one style without dating it. A serial shaped like ALXMXT0055 (a plant character, three letters, XT and four digits) matches the example Johnson Controls prints for its Solution XT and YORK Custom air handlers in service bulletin SI0003. That bulletin reads only its first character, the plant: A = Albany, T = Hattiesburg, C = East York, D = East York Coils, 2 = Monterrey. No document this tool holds dates this style, so no date is read from it. The unit's label prints this same serial as its date code, and the job's records may give the ship date.
How old is my York furnace?
A York distributor's own serial sheet, "YORK Serial Number Information (production after 10/6/2004)" published by US Air Conditioning Distributors, prints this layout for York, and York's own service bulletins, headed "TECHNICAL SERVICE" and "SERVICE TIPS", print York furnace serial prefixes in it, each beside the month it stands for. Enter the furnace's serial above: the result gives the date and age and says which documents cover it. It covers serials of this layout: a facility letter the sheet lists (A, N, S or W), a digit, a month letter, a digit and six digits, built from October 2004 on. A York serial of another layout is read as usual, and the result says the date is not called a furnace's age.
Related Tools
HVAC Serial Number Lookup (All Brands)
The full decoder: 50+ brands across every major manufacturer family, with ambiguous formats shown honestly.
Tonnage From Model Number
The serial tells you the age; the model number tells you the size. Decode BTU capacity and tons from the model.
A2L Refrigerant Charge Limit Calculator
Replacing an old unit with R-454B or R-32 equipment? Check the room-size charge limits per UL 60335-2-40.
Same family, same decode rules: Coleman serial number lookup, Fraser-Johnston serial number lookup, Guardian serial number lookup, Luxaire serial number lookup.
Different brand on the data plate?
The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.