HVAC Serial Number Lookup

ICP Serial Number Lookup

ICP is part of the ICP family, alongside Airquest, Arcoaire, Comfortmaker, Day & Night, Heil, KeepRite, Tempstar. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.

Quick answer: ICP serial numbers (~late 1980s to present): Plant letter (sometimes omitted) + 2-digit year + 2-digit week + sequence. Year FIRST: the reverse of the Carrier order. Example: L943321238 = week 33 of 1994. The same rule covers Heil, Tempstar, Comfortmaker, Arcoaire, KeepRite, Airquest, and Day & Night.

Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.

7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. Some of the formats on this page are read from the manufacturer's own document; the others rest on secondary references, and each row below says which. A date stamped or printed on the data plate always outranks a serial decode.

ICP furnace not heating?

Its stop checks come first, then what its light or code means, on furnace codes for ICP. Type what the furnace shows and it opens there with the brand filled in.


ICP Serial Number Formats

FormatEraExampleConfidence
Plant letter (sometimes omitted) + 2-digit year + 2-digit week + sequence. Year FIRST: the reverse of the Carrier orderCross-checked across 3 secondary references, alongside a manufacturer document held. The manufacturer's document "Warranty Claims Overview", which says manufacture dates "are estimated from the serial number".~late 1980s to presentL943321238 = week 33 of 1994high
2-digit year + 2-digit week + letter + sequence. Visually identical to the Carrier layout but with the digit pairs swappedCross-checked across 2 secondary references, not a manufacturer document.1990s9414B39332 = week 14 of 1994 (Tempstar)medium

Some older or conflicting ICP formats are recognized but deliberately not decoded; the decoder explains why when it sees one instead of guessing.


Worked Example: ICP L943321238

Expected decode: week 33 of 1994. Character by character:

Week 33 of 1994 (about August)

L = plant letter

94 = year 1994 (year comes first on ICP brands)

33 = week 33

21238 = production sequence

Where the data plate carries an MFG DATE field, read that field instead. ICP order is year-then-week, the reverse of Carrier's week-then-year.

ICP serials from public records, dated

Each serial in the record tables below is listed under ICP in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026.

The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.

Myrtle Beach, South Carolina: 15 serials; the decoder reads 10 of 15 as the year listed and does not decode 2

The record: CMB HVAC Inventory and ICE Machine Inventory final.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
A113172377Not listed per unit2006Week 31 of 2011 (about August)A different year
A133273073Not listed per unit2006Week 32 of 2013 (about August)A different year
E111917409Not listed per unit2006Week 19 of 2011 (about May)A different year
G082220165Not listed per unit2008Week 22 of 2008 (about May)Same year
V082818852Not listed per unit2008Week 28 of 2008 (about July)Same year
E093703285Not listed per unit2009Week 37 of 2009 (about September)Same year
G102140071Not listed per unit2010Week 21 of 2010 (about May)Same year
U102211889Not listed per unit2010Week 22 of 2010 (about May)Same year
X10S084438Not listed per unit2010No readingNot decoded
E111708421Not listed per unit2011Week 17 of 2011 (about April)Same year
K110480465Not listed per unit2011Week 4 of 2011 (about January)Same year
X110480871Not listed per unit2011Week 4 of 2011 (about January)Same year
X111576997Not listed per unit2011Week 15 of 2011 (about April)Same year
X112667166Not listed per unit2011Week 26 of 2011 (about June)Same year
C12971112Not listed per unit2012No readingNot decoded
Wayne Township, New Jersey: 1 serial; the decoder reads 1 of 1 as the year listed

The record: Wayne, Township of LGEA 07282014 FINAL Redacted.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
E093415164Not listed per unit2009Week 34 of 2009 (about August)Same year

Reading ICP model numbers

The ICP lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the tonnage decoder.

Each line is identified from the maker document in its Document column. The example is a model in that line's layout, and the reading is what the tonnage decoder returns for it.
LineExample modelWhat the tonnage decoder readsDocument
EHNA electric heater kit (ICP)EHNA15K6FAn accessory kit: identified, no size is read518 06 1603 00
ICP fan coil (FVM, FXM, FEM, FSM, FCM)FVM4X1800ALAn indoor coil: 1.5 tons (18,000 BTU/h)Residential Model Nomenclatures
ICP FMA4X/FMA4P fan coilFMA4P2400ATAn indoor coil: 2 tons (24,000 BTU/h)496 14 8002 01
ICP WCHL fan coilWCHL305ABAn indoor coil: 2.5 tons (30,000 BTU/h)WCHL-55-02PD
ICP gas furnace (F, G, N, R brands)N80MSN0751714AA gas furnace: its size field is heating input, so no cooling tonnage is readN80MSNL2-65-01PD
ICP gas furnace (N brand)N92ESN0401410AA gas furnace: its size field is heating input, so no cooling tonnage is readResidential Model Nomenclatures
ICP HAC0 10 SEER split system air conditionerHAC024AKCThe outdoor unit of a split system air conditioner: 2 tons (24,000 BTU/h)421 11 3202 00
ICP NAC0 10 SEER split system air conditionerNAC024AKCThe outdoor unit of a split system air conditioner: 2 tons (24,000 BTU/h)421 11 3002 00
ICP WPG4 package gas/electric unitWPG4364090RKB1A packaged unit: 3 tons (36,000 BTU/h)462 55 2004 02

CPSC recall notices naming ICP

Recall 97-012 · 1996-10-29

Hazard, in the notice's words: “Heat exchangers in the furnace can crack.”

Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.


ICP Refrigerant Timeline

Manufacture yearRefrigerant the years point toNotes
through 2005R-22Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22.
2006 to 2009R-22 or R-410AMixed window during the 13 SEER transition. The model prefix digit is the reliable signal (4 = R-410A).
2010 to 2024R-410AFrom January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024.
2025 and laterR-454BAll ICP brands moved to R-454B for the January 1, 2025 EPA deadline, matching parent Carrier, with a factory leak-dissipation system on A2L units.

The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.


ICP Warranty Terms

ICP warranty lookup

No page of ICP's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered.

What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the ICP warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.

One U.S. Consumer Product Safety Commission recall notice this tool matches names ICP equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.

The ICP warranty terms held here

35 ICP air conditioner and heat pump warranty certificate editions covering ICP are held here, from 401 06 1010 00 (Orig. 9/8//97) to ACHP-ICP-08WAR (02/26). Every one prints a base parts term of 5 years for its residential row; 401 06 4010 03 and 401 06 4010 04 give it only to the series their 5-year row lists, and the other rows they print are not registered here. Those that print a registered term give 10 years if registered within 90 days (401 06 4300 02 to ACHP-ICP-08WAR), except on the models an edition excepts. They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them tie their registered term to the original owner; ACHP-ICP-06WAR (03/25) prints: "If properly registered within ninety (90) days after original installation, parts are warranted for a period of ten (10) years to the original purchaser". It also prints: "In Texas and other jurisdictions where applicable, the subsequent owner's warranty duration shall match that of original owner (10 or 5 years, based on registration), as described in applicable law." Some of them print a separate term for a later owner, in a Subsequent Owners column; the result reads it when the owner is stated. None pays for labour.

Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. 401 06 4010 03 (Aug 2007) to 401 06 4010 04 (June 2008) give their five-year row only to the series they list (the newest, 401 06 4010 04 (June 2008): T4A4, H4A4, C4A4, T4H4, H4H4, C4H4, T4A3, H4A3, C4A3, T4H3, H4H3, C4H3, T2A3, H2A3, C2A3, T2H3, H2H3, C2H3, N4A3, N4A4, N2A3, N2A4, N4H3, N4H4, N2H3, N2H4, HC4A3, HC4H3), so for a unit built from October 1997 (from which 401 06 1010 00 (Orig. 9/8//97) is in force by its printed effective line) and before February 2009, from which 401 06 4300 02 (Aug 2009) is in force by its printed effective line, the result also asks for the model number, and a model in a family those editions print with another term is not worked out. Only the maker's records show whether a unit was registered.

Source: the maker's own limited warranty certificates, each identified by the part number printed on it; the serial result names the edition each term comes from, and the statute where a line quotes one.


Frequently Asked Questions

How old is my ICP unit?

Decode the serial number from the data plate. The dominant ICP format (~late 1980s to present) is: Plant letter (sometimes omitted) + 2-digit year + 2-digit week + sequence. Year FIRST: the reverse of the Carrier order. Example: L943321238 decodes to week 33 of 1994. Subtract the decoded year from the current year for the age.

Which brands share the ICP serial number format?

ICP is part of the ICP family, alongside Airquest, Arcoaire, Comfortmaker, Day & Night, Heil, KeepRite, and Tempstar. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.

Has the ICP serial decode been checked against serials somebody else dated?

ICP letter + year-week (L + YYWW): Read against 21 serials where a public body's own equipment schedule prints a year beside the serial (Salem, New Hampshire; Mobile, Alabama; Myrtle Beach, South Carolina; Wayne Township, New Jersey; the year sits under a column headed Year on 15, under a column headed Year Manuf on 4, on a line labelled YEAR on 1, and in a row labelled Year Manufactured on 1, 16 of which the document does not define), 5 name an equipment type, 2 of them condenser, across 4 equipment types: 18 matched the reading shown first, 3 did not match any reading (the published year ran earlier than this tool's reading on all 3).

No serial with a date published outside this tool has produced a reading through the ICP year-week + letter (YYWW + letter) format yet. No document from the company that built the unit is held for it, so the rule rests on the secondary references this tool records.

Across the ICP formats on this page, 2 serials with a date published outside this tool produced no reading at all (Myrtle Beach, South Carolina). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.

Where someone outside this tool wrote down a different year for a unit, that year is shown here rather than dropped. It is that publisher's record for the unit, and a schedule or a listing can carry a replacement, system or lot year rather than the build year. The MFG DATE on the unit's data plate is the build date.

What refrigerant does an ICP unit use?

By manufacture year: through 2005: R-22; 2006 to 2009: R-22 or R-410A; 2010 to 2024: R-410A; 2025 and later: R-454B. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.

How do I look up my ICP warranty?

No page of ICP's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered. What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the ICP warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit. One U.S. Consumer Product Safety Commission recall notice this tool matches names ICP equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.

Is my ICP unit still under warranty?

35 ICP air conditioner and heat pump warranty certificate editions covering ICP are held here, from 401 06 1010 00 (Orig. 9/8//97) to ACHP-ICP-08WAR (02/26). Every one prints a base parts term of 5 years for its residential row; 401 06 4010 03 and 401 06 4010 04 give it only to the series their 5-year row lists, and the other rows they print are not registered here. Those that print a registered term give 10 years if registered within 90 days (401 06 4300 02 to ACHP-ICP-08WAR), except on the models an edition excepts. They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them tie their registered term to the original owner; ACHP-ICP-06WAR (03/25) prints: "If properly registered within ninety (90) days after original installation, parts are warranted for a period of ten (10) years to the original purchaser". It also prints: "In Texas and other jurisdictions where applicable, the subsequent owner's warranty duration shall match that of original owner (10 or 5 years, based on registration), as described in applicable law." Some of them print a separate term for a later owner, in a Subsequent Owners column; the result reads it when the owner is stated. None pays for labour. Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. 401 06 4010 03 (Aug 2007) to 401 06 4010 04 (June 2008) give their five-year row only to the series they list (the newest, 401 06 4010 04 (June 2008): T4A4, H4A4, C4A4, T4H4, H4H4, C4H4, T4A3, H4A3, C4A3, T4H3, H4H3, C4H3, T2A3, H2A3, C2A3, T2H3, H2H3, C2H3, N4A3, N4A4, N2A3, N2A4, N4H3, N4H4, N2H3, N2H4, HC4A3, HC4H3), so for a unit built from October 1997 (from which 401 06 1010 00 (Orig. 9/8//97) is in force by its printed effective line) and before February 2009, from which 401 06 4300 02 (Aug 2009) is in force by its printed effective line, the result also asks for the model number, and a model in a family those editions print with another term is not worked out. Only the maker's records show whether a unit was registered.

Why do some ICP serial numbers refuse to decode?

A serial beginning with Z matches an older ICP style. ICP's own date code letter, which this tool holds, prints its layouts with other leading characters and none beginning with Z, so this tool reads no date from this style. If the data plate has an MFG DATE field, that is the reliable source.

How old is my ICP furnace?

No maker document held here dates ICP furnaces, so the tool does not call a date a ICP furnace's age; it reads the serial by the same rule it uses for ICP's other equipment.


Related Tools

Same family: Airquest serial number lookup, Arcoaire serial number lookup, Comfortmaker serial number lookup, Day & Night serial number lookup, Heil serial number lookup, KeepRite serial number lookup, Tempstar serial number lookup.

Different brand on the data plate?

The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.