HVAC Serial Number Lookup

Airquest Serial Number Lookup: AC and Furnace Age

Airquest is part of the ICP family, alongside Arcoaire, Comfortmaker, Day & Night, Heil, ICP, KeepRite, Tempstar. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.

Quick answer: Airquest serial numbers (~late 1980s to present): Plant letter (sometimes omitted) + 2-digit year + 2-digit week + sequence. Year FIRST: the reverse of the Carrier order. Example: L943321238 = week 33 of 1994. The same rule covers Heil, Tempstar, Comfortmaker, Arcoaire, KeepRite, ICP, and Day & Night.

Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.

7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. Some of the formats on this page are read from the manufacturer's own document; the others rest on secondary references, and each row below says which. A date stamped or printed on the data plate always outranks a serial decode.


Airquest Serial Number Formats

FormatEraExampleConfidence
Plant letter (sometimes omitted) + 2-digit year + 2-digit week + sequence. Year FIRST: the reverse of the Carrier orderCross-checked across 3 secondary references, alongside a manufacturer document held. The manufacturer's document "Warranty Claims Overview", which says manufacture dates "are estimated from the serial number".~late 1980s to presentL943321238 = week 33 of 1994high
2-digit year + 2-digit week + letter + sequence. Visually identical to the Carrier layout but with the digit pairs swappedCross-checked across 2 secondary references, not a manufacturer document.1990s9414B39332 = week 14 of 1994 (Tempstar)medium
One or two location letters + 1 year digit + 2-digit week + 5-digit unit number; the year digit repeats every ten yearsA manufacturer document, held as a retained copy. No secondary reference is relied on. The manufacturer's document "Date Code Identification", which says the serial "normally consists of nine or ten characters".January 1971 to October 1987H20410012 = week 4 of 1972 or 1982 (the year digit repeats)medium

Some older or conflicting Airquest formats are recognized but deliberately not decoded; the decoder explains why when it sees one instead of guessing.


Worked Example: Airquest L943321238

Expected decode: week 33 of 1994. Character by character:

Week 33 of 1994 (about August)

L = plant letter

94 = year 1994 (year comes first on ICP brands)

33 = week 33

21238 = production sequence

Where the data plate carries an MFG DATE field, read that field instead. ICP order is year-then-week, the reverse of Carrier's week-then-year.


Airquest Refrigerant Timeline

Manufacture yearRefrigerant the years point toNotes
through 2005R-22Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22.
2006 to 2009R-22 or R-410AMixed window during the 13 SEER transition. The model prefix digit is the reliable signal (4 = R-410A).
2010 to 2024R-410AFrom January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024.
2025 and laterR-454BAll ICP brands moved to R-454B for the January 1, 2025 EPA deadline, matching parent Carrier, with a factory leak-dissipation system on A2L units.

The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.


Airquest Warranty Terms

Airquest warranty lookup

No page of Airquest's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered.

What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Airquest warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.

The Airquest warranty terms held here

35 ICP air conditioner and heat pump warranty certificate editions covering Airquest are held here, from 401 06 1010 00 (Orig. 9/8//97) to ACHP-ICP-08WAR (02/26). Every one prints a base parts term of 5 years for its residential row; 401 06 4010 03 and 401 06 4010 04 give it only to the series their 5-year row lists, and the other rows they print are not registered here. Those that print a registered term give 10 years if registered within 90 days (401 06 4300 02 to ACHP-ICP-08WAR), except on the models an edition excepts. They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them tie their registered term to the original owner; ACHP-ICP-06WAR (03/25) prints: "If properly registered within ninety (90) days after original installation, parts are warranted for a period of ten (10) years to the original purchaser". It also prints: "In Texas and other jurisdictions where applicable, the subsequent owner's warranty duration shall match that of original owner (10 or 5 years, based on registration), as described in applicable law." Some of them print a separate term for a later owner, in a Subsequent Owners column; the result reads it when the owner is stated. None pays for labour.

Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. 401 06 4010 03 (Aug 2007) to 401 06 4010 04 (June 2008) give their five-year row only to the series they list (the newest, 401 06 4010 04 (June 2008): T4A4, H4A4, C4A4, T4H4, H4H4, C4H4, T4A3, H4A3, C4A3, T4H3, H4H3, C4H3, T2A3, H2A3, C2A3, T2H3, H2H3, C2H3, N4A3, N4A4, N2A3, N2A4, N4H3, N4H4, N2H3, N2H4, HC4A3, HC4H3), so for a unit built from October 1997 (from which 401 06 1010 00 (Orig. 9/8//97) is in force by its printed effective line) and before February 2009, from which 401 06 4300 02 (Aug 2009) is in force by its printed effective line, the result also asks for the model number, and a model in a family those editions print with another term is not worked out. Only the maker's records show whether a unit was registered.

Source: the maker's own limited warranty certificates, each identified by the part number printed on it; the serial result names the edition each term comes from, and the statute where a line quotes one.


Frequently Asked Questions

How old is my Airquest unit?

Decode the serial number from the data plate. The dominant Airquest format (~late 1980s to present) is: Plant letter (sometimes omitted) + 2-digit year + 2-digit week + sequence. Year FIRST: the reverse of the Carrier order. Example: L943321238 decodes to week 33 of 1994. Subtract the decoded year from the current year for the age.

Which brands share the Airquest serial number format?

Airquest is part of the ICP family, alongside Arcoaire, Comfortmaker, Day & Night, Heil, ICP, KeepRite, and Tempstar. These brands come off shared production lines with the same data plates, so this page's other serial number formats apply across the family; the ICP 1971 to 1987 (location letter + year digit + week) format applies, among these brands, only to Airquest, Heil, and Tempstar. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.

Has the Airquest serial decode been checked against serials somebody else dated?

ICP letter + year-week (L + YYWW): Read against 21 serials where a public body's own equipment schedule prints a year beside the serial (Salem, New Hampshire; Mobile, Alabama; Myrtle Beach, South Carolina; Wayne Township, New Jersey; the year sits under a column headed Year on 15, under a column headed Year Manuf on 4, on a line labelled YEAR on 1, and in a row labelled Year Manufactured on 1, 16 of which the document does not define), 5 name an equipment type, 2 of them condenser, across 4 equipment types: 18 matched the reading shown first, 3 did not match any reading (the published year ran earlier than this tool's reading on all 3).

No serial with a date published outside this tool has produced a reading through the ICP 1971 to 1987 (location letter + year digit + week) format yet. That format is read from a document published by the company that built the unit.

No serial with a date published outside this tool has produced a reading through the ICP year-week + letter (YYWW + letter) format yet. No document from the company that built the unit is held for it, so the rule rests on the secondary references this tool records.

Across the Airquest formats on this page, 2 serials with a date published outside this tool produced no reading at all (Myrtle Beach, South Carolina). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.

Where someone outside this tool wrote down a different year for a unit, that year is shown here rather than dropped. It is that publisher's record for the unit, and a schedule or a listing can carry a replacement, system or lot year rather than the build year. The MFG DATE on the unit's data plate is the build date.

What refrigerant does an Airquest unit use?

By manufacture year: through 2005: R-22; 2006 to 2009: R-22 or R-410A; 2010 to 2024: R-410A; 2025 and later: R-454B. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.

How do I look up my Airquest warranty?

No page of Airquest's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered. What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Airquest warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.

Is my Airquest unit still under warranty?

35 ICP air conditioner and heat pump warranty certificate editions covering Airquest are held here, from 401 06 1010 00 (Orig. 9/8//97) to ACHP-ICP-08WAR (02/26). Every one prints a base parts term of 5 years for its residential row; 401 06 4010 03 and 401 06 4010 04 give it only to the series their 5-year row lists, and the other rows they print are not registered here. Those that print a registered term give 10 years if registered within 90 days (401 06 4300 02 to ACHP-ICP-08WAR), except on the models an edition excepts. They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them tie their registered term to the original owner; ACHP-ICP-06WAR (03/25) prints: "If properly registered within ninety (90) days after original installation, parts are warranted for a period of ten (10) years to the original purchaser". It also prints: "In Texas and other jurisdictions where applicable, the subsequent owner's warranty duration shall match that of original owner (10 or 5 years, based on registration), as described in applicable law." Some of them print a separate term for a later owner, in a Subsequent Owners column; the result reads it when the owner is stated. None pays for labour. Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. 401 06 4010 03 (Aug 2007) to 401 06 4010 04 (June 2008) give their five-year row only to the series they list (the newest, 401 06 4010 04 (June 2008): T4A4, H4A4, C4A4, T4H4, H4H4, C4H4, T4A3, H4A3, C4A3, T4H3, H4H3, C4H3, T2A3, H2A3, C2A3, T2H3, H2H3, C2H3, N4A3, N4A4, N2A3, N2A4, N4H3, N4H4, N2H3, N2H4, HC4A3, HC4H3), so for a unit built from October 1997 (from which 401 06 1010 00 (Orig. 9/8//97) is in force by its printed effective line) and before February 2009, from which 401 06 4300 02 (Aug 2009) is in force by its printed effective line, the result also asks for the model number, and a model in a family those editions print with another term is not worked out. Only the maker's records show whether a unit was registered.

Why do some Airquest serial numbers refuse to decode?

A serial beginning with Z matches an older ICP style. ICP's own date code letter, which this tool holds, prints its layouts with other leading characters and none beginning with Z, so this tool reads no date from this style. If the data plate has an MFG DATE field, that is the reliable source.

How old is my Airquest furnace?

ICP's own Date Code Identification letter is headed "PRODUCT All Products"; it does not name furnaces. Enter the furnace's serial above: the result gives the date and age and says which document covers it, and that it covers furnaces by its scope. It covers serials of these layouts: one plant letter, then two digits for the year, two for the week and a five-digit run number; or one plant letter, one digit for the year, two for the week and a five-digit number (made from January 1971 to October 1987). A Airquest serial of another layout is read as usual, and the result says the date is not called a furnace's age.


Related Tools

Same family: Arcoaire serial number lookup, Comfortmaker serial number lookup, Day & Night serial number lookup, Heil serial number lookup, ICP serial number lookup, KeepRite serial number lookup, Tempstar serial number lookup.

Different brand on the data plate?

The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.