HVAC Serial Number Lookup
Ameristar Serial Number Lookup: AC and Furnace Age
Ameristar is part of the Trane family, alongside American Standard, Trane. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.
Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.
Every serial format on this page is read from a document published by the company that built the unit, held as a retained copy. The manufacturer's document "Residential & Light Commercial Product Handbook: Equipment Date Identification", which says accessories and some coils "may have only three digits to indicate date code". A date stamped or printed on the data plate always outranks a serial decode.
Ameristar Serial Number Formats
| Format | Era | Example | Confidence |
|---|---|---|---|
| 10+ characters starting with 2 digits; digits 1-2 = year, digits 3-4 = week. Digit 5 = the day of the week on Trane's date code page; Trane's light commercial date code article (its scope names Trane units) prints a layout of year, week, sequence number and plant, with no day digit, in which digit 5 starts the sequence numberCross-checked across 3 secondary references, alongside a manufacturer document held. The manufacturer's document "Residential & Light Commercial Product Handbook: Equipment Date Identification", which says accessories and some coils "may have only three digits to indicate date code". | 2009 to present | 11241KADBB = week 24 of 2011 | high |
| 9 characters starting with one digit; digit 1 = year (2=2002 ... 9=2009), digits 2-3 = week. Digit 4 = the day of the week on Trane's date code page; Trane's light commercial date code article (its scope names Trane units) prints a layout of year, week, sequence number and plant, with no day digitCross-checked across 3 secondary references, alongside a manufacturer document held. The manufacturer's document "Residential & Light Commercial Product Handbook: Equipment Date Identification", which says accessories and some coils "may have only three digits to indicate date code". | 2002 to 2009 | 81422S41G = week 14 of 2008 | high |
| 9 characters; first letter = year (W=1983 ... Z=2001), digits 2-3 = week. S = 1986 and Z = 2001 sit out of order. Digit 4 = the day of the week on Trane's date code page; Trane's light commercial date code article (its scope names Trane units) prints a layout of year, week, sequence number and plant, with no day digit. Trane's own date code page prints O or A = 1980, T = 1981, U = 1982, which this tool readsCross-checked across 2 secondary references, alongside a manufacturer document held. S and Z sit out of alphabetical order in this table, and reading them in alphabetical order dates both years wrong. The manufacturer's document "Residential & Light Commercial Product Handbook: Equipment Date Identification", which says accessories and some coils "may have only three digits to indicate date code". | 1980 to 2001 | R1742DWBF = week 17 of 2000 | high |
Some older or conflicting Ameristar formats are recognized but deliberately not decoded; the decoder explains why when it sees one instead of guessing.
Worked Example: Ameristar 11241KADBB
Expected decode: week 24 of 2011. Character by character:
11 = year 2011 (digits 1-2)
24 = week 24 (digits 3-4)
1 (digit 5): Trane's date code page (its scope names Trane units, not Ameristar units) prints this position as the day of the week; Trane's light commercial date code article (its scope names Trane units, not Ameristar units) prints a layout of year, week, sequence number and plant, with no day digit, in which this position starts the sequence number
Cross-check: the ANSI rating year on the data plate should equal or slightly precede this year.
CPSC recall notices naming Ameristar
Hazard, in the notice's words: “The ground wire in the furnace’s junction box can become loose. If an electrical component then fails and short circuits, the unit poses a shock hazard.”
Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.
Ameristar Refrigerant Timeline
| Manufacture year | Refrigerant the years point to | Notes |
|---|---|---|
| through 2005 | R-22 | Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22. |
| 2006 to 2009 | R-22 or R-410A | Transition window: both 2TT (R-22) and 4TT (R-410A) lines sold. The model prefix, not the year, is authoritative here. |
| 2010 to 2024 | R-410A | From January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024. Trane model prefix 4. |
| 2025 and later | R-454B | Trane began releasing R-454B equipment during 2024; from January 1, 2025 essentially all Trane/American Standard residential product is R-454B (model prefix 5). Data plate governs on 2024 builds. |
The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.
Ameristar Warranty Terms
Ameristar warranty lookup
No page of Ameristar's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered.
Enter the serial in the lookup on this page for the build date and the unit's age. No Ameristar warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit.
One U.S. Consumer Product Safety Commission recall notice this tool matches names Ameristar equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
What this tool holds on Ameristar's warranty
Trane and American Standard certificate GW-658-0119, for products made from January 1, 2017 (the maker's copy, held here; the warranty card reads it for Trane and American Standard units), extends its base terms on the products its tables list, up to ten years on parts and, on some series (outdoor 4TTX, 4TTV, 4TWX, 4TWV, 4A6H7, 4A6V, 4A7A7 and 4A7V, and packaged 4WCZ6, 4DCZ6 and 4YCZ6), twelve on the compressor, when the product is registered online within sixty days after the commencement date. Its base terms differ by product: some outdoor units, including its R-22 models, and the ductless systems it marks as sold in Canada only print one year. Where the installation and start-up date cannot be verified by the installer's invoice, the term starts sixty days after the factory manufacture date.
The result does not work out a dated term for Ameristar: no Ameristar certificate is registered for that here. Only the maker's records show whether a unit was registered.
Source: Trane limited warranty certificate GW-658-0119 (trane.com).
Frequently Asked Questions
How old is my Ameristar unit?
Decode the serial number from the data plate. The dominant Ameristar format (2009 to present) is: 10+ characters starting with 2 digits; digits 1-2 = year, digits 3-4 = week. Example: 11241KADBB decodes to week 24 of 2011. Subtract the decoded year from the current year for the age.
Which brands share the Ameristar serial number format?
Ameristar is part of the Trane family, alongside American Standard and Trane. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.
Has the Ameristar serial decode been checked against serials somebody else dated?
Trane two-digit year (2009-present): Checked against 7 serials whose date a recall notice published by someone other than us states (CPSC recall notice 17-709, CPSC recall notice 25-369), 5 of them gas/electric packaged units, models 4YCZ50xx, across 2 equipment types. The date this tool reads first was consistent with the published window on all 7. Also read against 22 serials where a public body's own equipment schedule prints a year beside the serial (Winter Park, Florida; Norcross, Georgia; Wayne Township, New Jersey; the year sits under a column headed Year on 21, and in a row labelled Year Manufactured on 1, 21 of which the document does not define), 21 name an equipment type, 9 of them condensing unit, across 8 equipment types: 22 matched the reading shown first; and 2 serials where a seller entered a year in the listing's own year field or, for some, beside the serial in the listing's description on a government surplus listing for the serial (government surplus auction listings), 1 of them pallet of four HVAC units, across 2 equipment types: 2 matched the reading shown first; a seller's year is shown here for the record and is not counted toward this format's check.
Trane single-digit year (2002-2009): Checked against 3 serials whose date a recall notice published by someone other than us states (CPSC recall notice 05-104), 2-5 ton gas/electric packaged units, models YCP/YCX/YCY/YCZ. The date this tool reads first was consistent with the published window on all 3. Also read against 10 serials where a public body's own equipment schedule prints a year beside the serial (Norcross, Georgia; Salem, New Hampshire; Wayne Township, New Jersey; Winter Park, Florida; the year sits under a column headed Year on 6, in a row labelled Year Manufactured on 3, and on a line labelled YEAR on 1, 7 of which the document does not define), 7 name an equipment type, 4 of them condensing unit, across 4 equipment types: 10 matched the reading shown first. This format was also read against 1 serial on an air filtration system (CPSC recall notice 07-567): 1 matched the reading shown first. It is shown for the record and not counted toward this format's check, because the equipment is not a heating or cooling unit.
Trane letter-year (1980-2001): Checked against 2 serials whose date a recall notice published by someone other than us states (CPSC recall notice 01-507), Voyager series light commercial rooftop gas/electric units. The date this tool reads first was consistent with the published window on all 2. Also read against 2 serials where a public body's own equipment schedule prints a year beside the serial (Winter Park, Florida; Norcross, Georgia; the year sits under a column headed Year, which the document does not define), 1 of them condensing unit - heat pump, across 2 equipment types: 2 matched the reading shown first; and 1 serial where a seller entered a year in the listing's own year field on a government surplus listing for the serial (government surplus auction listings), XE1100 3-ton unit: 1 matched the reading shown first; a seller's year is shown here for the record and is not counted toward this format's check.
Across the Ameristar formats on this page, 7 serials with a date published outside this tool produced no reading at all (Winter Park, Florida; Wayne Township, New Jersey; government surplus auction listings). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.
What refrigerant does an Ameristar unit use?
By manufacture year: through 2005: R-22; 2006 to 2009: R-22 or R-410A; 2010 to 2024: R-410A; 2025 and later: R-454B. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.
How do I look up my Ameristar warranty?
No page of Ameristar's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered. Enter the serial in the lookup on this page for the build date and the unit's age. No Ameristar warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit. One U.S. Consumer Product Safety Commission recall notice this tool matches names Ameristar equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
Is my Ameristar unit still under warranty?
Trane and American Standard certificate GW-658-0119, for products made from January 1, 2017 (the maker's copy, held here; the warranty card reads it for Trane and American Standard units), extends its base terms on the products its tables list, up to ten years on parts and, on some series (outdoor 4TTX, 4TTV, 4TWX, 4TWV, 4A6H7, 4A6V, 4A7A7 and 4A7V, and packaged 4WCZ6, 4DCZ6 and 4YCZ6), twelve on the compressor, when the product is registered online within sixty days after the commencement date. Its base terms differ by product: some outdoor units, including its R-22 models, and the ductless systems it marks as sold in Canada only print one year. Where the installation and start-up date cannot be verified by the installer's invoice, the term starts sixty days after the factory manufacture date. The result does not work out a dated term for Ameristar: no Ameristar certificate is registered for that here. Only the maker's records show whether a unit was registered.
Why do some Ameristar serial numbers refuse to decode?
A nine-character Trane serial with a letter as its fourth character is not in the layout Trane's own date code page prints, where that character is the day of the week, a digit, so no date is read from it. Trane's page covers its residential and light commercial products; this tool holds no Trane serial chart for chillers or other applied equipment. Read the manufacture date off the data plate. In the year table Trane's own date code page prints for its residential and light commercial products and compressors, no year is printed for a first letter I, Q or V, and every letter that table does print, from O or A for 1980 to Z for 2001, is read by this tool. The same page has a separate table for Ducane oil and horizontal gas furnaces with letters of its own, including Q for 1984, which this tool does not read. Verify with the ANSI rating year printed on the data plate.
How old is my Ameristar furnace?
Trane's own Equipment Date Identification page (its scope names Trane units, not Ameristar units) dates the serial numbers "on all Trane central air conditioning and heating products"; it names gas furnaces only in its notes on dedicated horizontal gas furnaces. Enter the furnace's serial above: the result gives the date and age and says which document covers it, and that it covers furnaces by its scope. Trane's page reads a gas furnace built only for horizontal installation on a separate year column, so a serial opening with L, M, N, 85 to 89 or 9 is not called a furnace's age; on any other Ameristar furnace the page's own rule gives the date.
Related Tools
HVAC Serial Number Lookup (All Brands)
The full decoder: 50+ brands across every major manufacturer family, with ambiguous formats shown honestly.
Tonnage From Model Number
The serial tells you the age; the model number tells you the size. Decode BTU capacity and tons from the model.
A2L Refrigerant Charge Limit Calculator
Replacing an old unit with R-454B or R-32 equipment? Check the room-size charge limits per UL 60335-2-40.
Same family, same decode rules: American Standard serial number lookup, Trane serial number lookup.
Different brand on the data plate?
The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.