HVAC Serial Number Lookup

Trane Serial Number Lookup: AC and Furnace Age

Trane is part of the Trane family, alongside American Standard, Ameristar. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.

Quick answer: Trane serial numbers (2009 to present): 10+ characters starting with 2 digits; digits 1-2 = year, digits 3-4 = week. Example: 11241KADBB = week 24 of 2011. The same rule covers American Standard and Ameristar.

Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.

Every serial format on this page is read from a document published by the company that built the unit, held as a retained copy. The manufacturer's document "Residential & Light Commercial Product Handbook: Equipment Date Identification", which says accessories and some coils "may have only three digits to indicate date code". A date stamped or printed on the data plate always outranks a serial decode.

Trane furnace not heating?

Its stop checks come first, then what its light or code means, on furnace codes for Trane. Type what the furnace shows and it opens there with the brand filled in.


Trane Serial Number Formats

FormatEraExampleConfidence
10+ characters starting with 2 digits; digits 1-2 = year, digits 3-4 = week. Digit 5 = the day of the week on Trane's date code page; Trane's light commercial date code article (its scope names Trane units) prints a layout of year, week, sequence number and plant, with no day digit, in which digit 5 starts the sequence numberCross-checked across 3 secondary references, alongside 2 manufacturer documents held. The manufacturer's document "Residential & Light Commercial Product Handbook: Equipment Date Identification", which says accessories and some coils "may have only three digits to indicate date code".2009 to present11241KADBB = week 24 of 2011high
9 characters starting with one digit; digit 1 = year (2=2002 ... 9=2009), digits 2-3 = week. Digit 4 = the day of the week on Trane's date code page; Trane's light commercial date code article (its scope names Trane units) prints a layout of year, week, sequence number and plant, with no day digitCross-checked across 3 secondary references, alongside 2 manufacturer documents held. The manufacturer's document "Residential & Light Commercial Product Handbook: Equipment Date Identification", which says accessories and some coils "may have only three digits to indicate date code".2002 to 200981422S41G = week 14 of 2008high
9 characters; first letter = year (W=1983 ... Z=2001), digits 2-3 = week. S = 1986 and Z = 2001 sit out of order. Digit 4 = the day of the week on Trane's date code page; Trane's light commercial date code article (its scope names Trane units) prints a layout of year, week, sequence number and plant, with no day digit. Trane's own date code page prints O or A = 1980, T = 1981, U = 1982, which this tool readsCross-checked across 2 secondary references, alongside 2 manufacturer documents held. S and Z sit out of alphabetical order in this table, and reading them in alphabetical order dates both years wrong. The manufacturer's document "Residential & Light Commercial Product Handbook: Equipment Date Identification", which says accessories and some coils "may have only three digits to indicate date code".1980 to 2001R1742DWBF = week 17 of 2000high

Some older or conflicting Trane formats are recognized but deliberately not decoded; the decoder explains why when it sees one instead of guessing.


Worked Example: Trane 11241KADBB

Expected decode: week 24 of 2011. Character by character:

Week 24 of 2011 (about June)

11 = year 2011 (digits 1-2)

24 = week 24 (digits 3-4)

1 (digit 5): Trane's date code page prints this position as the day of the week; Trane's light commercial date code article prints a layout of year, week, sequence number and plant, with no day digit, in which this position starts the sequence number

Cross-check: the ANSI rating year on the data plate should equal or slightly precede this year.

Trane serials from public records, dated

Each serial in the record tables below is listed under Trane in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026. Serials on government surplus listings, a weaker check, follow the records.

The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.

Winter Park, Florida: 22 serials; the decoder reads 18 of 22 as the year listed and does not decode 4

The records: Chamber of commerce energy audit 2023-09, City hall energy audit 2023-09, Magnolia water plant energy audit 2023-09, Police training center energy audit 2023-09, Train station energy audit 2023-09, Swoope water plant energy audit 2023-09.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
E40248489Condensing Unit - Heat Pump1990Week 40 of 1990 (about October)Same year
7022YEH2FCondensing Unit2007Week 2 of 2007 (about January)Same year
7072S8LBDAir Conditioning2007Week 7 of 2007 (about February)Same year
709100240LRooftop Unit2007No readingNot decoded
11181TRE5FCondensing Unit2011Week 18 of 2011 (about May)Same year
112020N15FCondensing Unit2011Week 20 of 2011 (about May)Same year
112620JM2VAir Handling Unit2011Week 26 of 2011 (about June)Same year
11294PBT5FCondensing Unit2011Week 29 of 2011 (about July)Same year
11303SDS2VAir Handling Unit2011Week 30 of 2011 (about July)Same year
K11K09398AAir Handling Unit2011No readingNot decoded
K11K09405AAir Handling Unit2011No readingNot decoded
K11K09418AAir Handling Unit2011No readingNot decoded
13154KX45FCondensing Unit2013Week 15 of 2013 (about April)Same year
13362RTN2FCondensing Unit2013Week 36 of 2013 (about September)Same year
192313296LPackaged Rooftop Unit2019Week 23 of 2019 (about June)Same year
203611029DRooftop Unit2020Week 36 of 2020 (about September)Same year
214210978IPackaged Rooftop Air Handling Unit2021Week 42 of 2021 (about October)Same year
21525BD63FXR14 Heat Pump2021Week 52 of 2021 (about December)Same year
2204452P3VAir Handling Unit2022Week 4 of 2022 (about January)Same year
22044W683VAir Handling Unit2022Week 4 of 2022 (about January)Same year
22135ME11FCondensing Unit2022Week 13 of 2022 (about March)Same year
22135MNF1FCondensing Unit2022Week 13 of 2022 (about March)Same year
Norcross, Georgia: 11 serials; the decoder reads 11 of 11 as the year listed

The record: Document Center file 8177.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
Z3648T92GFurnace2001Week 36 of 2001 (about September)Same year
6241UFG6VGas furnace2006Week 24 of 2006 (about June)Same year
626329KADCondensing Unit2006Week 26 of 2006 (about June)Same year
6305KH85FCondensing unit2006Week 30 of 2006 (about July)Same year
7232M851GFurnace2007Week 23 of 2007 (about June)Same year
170513670LPkg. Unit2017Week 5 of 2017 (about February)Same year
192514903LPkg. Unit2019Week 25 of 2019 (about June)Same year
230614Y81FCondensing Unit2023Week 6 of 2023 (about February)Same year
2319370DGFCondensing Unit2023Week 19 of 2023 (about May)Same year
23195K95HGFurnace2023Week 19 of 2023 (about May)Same year
23195K96HGFurnace2023Week 19 of 2023 (about May)Same year
Wayne Township, New Jersey: 5 serials; the decoder reads 4 of 5 as the year listed and does not decode 1

The record: Wayne, Township of LGEA 07282014 FINAL Redacted.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
7232Y1JADNot listed per unit2007Week 23 of 2007 (about June)Same year
8464N2H2FNot listed per unit2008Week 46 of 2008 (about November)Same year
9381PBUADNot listed per unit2009Week 38 of 2009 (about September)Same year
C10A00417Not listed per unit2010No readingNot decoded
124110340DNot listed per unit2012Week 41 of 2012 (about October)Same year
Salem, New Hampshire: 1 serial; the decoder reads 1 of 1 as the year listed

The record: Document Center file 2529.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
7265N723FCondensing unit2007Week 26 of 2007 (about June)Same year

Trane serials on government surplus listings

On these, the year is one a seller entered in the listing's own year field or, for some, beside the serial in the listing's description, not a year the manufacturer or a public record states, so it is a weaker check than a public record. “The decoder reads” is what the serial lookup on this page returns for the serial, worked out when this page was built in 2026. The listings are not named here, because a seller's entry is not a citation. 4 serials; the decoder reads 3 of 4 as the year listed and does not decode 1.

SerialEquipment, as listedYear a seller enteredThe decoder readsAgainst the year listed
M023N0DBFXE1100 3-ton unit1997Week 2 of 1997 (about January)Same year
L06K05181CVHF058FA commercial chiller2006No readingNot decoded
12082T802FXB13 heat pump2012Week 8 of 2012 (about February)Same year
230305296XPallet of four HVAC units2023Week 3 of 2023 (about January)Same year

Reading Trane model numbers

The Trane lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the Trane tonnage page.

Each line is identified from the maker document in its Document column. The example is a model in that line's layout, and the reading is what the tonnage decoder returns for it.
LineExample modelWhat the tonnage decoder readsDocument
Trane legacy split outdoor unit4TWV0036A1000AA3 tons (36,000 BTU/h)22-1746-04, 22-1725-04, 22-1904-1M-EN
Trane R-454B split outdoor unit5TTR5024A1000AA2 tons (24,000 BTU/h)22-8301-39
Trane R-454B Low Profile outdoor unit5HPL5036A1000AA3 tons (36,000 BTU/h)22-8301-39, ODR-PSD038A-EN, DLR-PSD004A-EN
RunTru by Trane outdoor unitA5AC3024B10002 tons (24,000 BTU/h)22-8301-39
Trane ProSpace PTAC (PTEF/PTHF)PTEF0702GAAA Trane packaged terminal unit (PTAC or PTHP): its legend prints this code in BTU/h, not a whole, half or quarter ton, so no tonnage is publishedPTAC-SVX002A-EN
Trane split system (1996 nomenclature, Pub. 22-1633-04)TWN018C100B1.5 tons (18,000 BTU/h), an estimatePub. No. 22-1633-04-1296 (EN)
Trane RTAC air-cooled Series R chillerRTAC140An air-cooled rotary chiller: large commercial equipment, outside this tool's range, so no tonnage is readRLC-PRC006M-EN
Trane Horizon outdoor air unit (OAD, OAN)OAND360A dedicated outdoor air unit: large commercial equipment, outside this tool's range, so no tonnage is readOAU-PRC008A-EN
Trane air handler (1996 nomenclature, Pub. 22-1633-04)TWV018B14An air handler: identified; its maker's document prints no model number legend, so no size is readPub. No. 22-1633-04-1296 (EN)
Trane indoor coil (1996 nomenclature, Pub. 22-1633-04)TXC031E5An indoor coil: identified; its maker's document prints no model number legend, so no size is readPub. No. 22-1633-04-1296 (EN)

CPSC recall notices naming Trane

Recall 25-369 · 2025-07-03

Hazard, in the notice's words: “The fuel gas valve can open unexpectedly, allowing a gas leak and posing a fire hazard.”

Recall 17-709 · 2016-11-08

Hazard, in the notice's words: “The ground wire in the furnace’s junction box can become loose. If an electrical component then fails and short circuits, the unit poses a shock hazard.”

Recall 14-737 · 2014-06-24

Hazard, in the notice's words: “The ground screws used in some units do not have the two threads required to provide sufficient grounding, posing a shock hazard to consumers.”

Recall 05-104 · 2005-02-11

Hazard, in the notice's words: “A gas leak can occur if there is a crack in the gas valve body near the inlet pipe connection. A build-up of gas in the burner compartment of the unit could occur, which could be ignited by an internal spark.”

Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.


Trane Refrigerant Timeline

Manufacture yearRefrigerant the years point toNotes
through 2005R-22Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22.
2006 to 2009R-22 or R-410ATransition window: both 2TT (R-22) and 4TT (R-410A) lines sold. The model prefix, not the year, is authoritative here.
2010 to 2024R-410AFrom January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024. Trane model prefix 4.
2025 and laterR-454BTrane began releasing R-454B equipment during 2024; from January 1, 2025 essentially all Trane/American Standard residential product is R-454B (model prefix 5). Data plate governs on 2024 builds.

The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.


Trane Warranty Terms

Trane warranty lookup

The maker's own page: Trane's own warranty lookup, at www.trane.com. The page reads: "Put in a serial number connected to your registration to view warranty terms." This page reads no maker's records and cannot show whether a unit was registered. Open Trane's own warranty lookup

What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Trane warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.

4 U.S. Consumer Product Safety Commission recall notices this tool matches name Trane equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.

The Trane warranty terms held here

11 Trane and American Standard air conditioner and heat pump warranty certificate editions covering Trane are held here, from 16-1000-27 (7/11) to GW-OTDR-2401B (© 2024). The base parts term they print for their residential row differs by edition: 5 years (16-1000-27 to GW-658-0119; GW-OTDR-2201B to GW-OTDR-2401B) and 10 years (GW-658-2032); 16-1000-27, 16-1000-28, 16-1000-32, 16-1000-39, 26-1000-40, GW-658-4217 and GW-658-0119 give it only to the series their row lists, and the other rows they print are not registered here. Each also prints a compressor term of its own for some outdoor series: 16-1000-27 and 16-1000-28, under "SINGLE PHASE R410 OUTDOOR UNITS" and its "Registered Limited Warranty Period", for TRANE: 4TTZ0, 4TTX6, 4TTX5, 4TWZ0, 4TWX6, 4TWX5. ASD: 4A7Z0, 4A7A6, 4A6Z0, 4A6H6: "compressor – twelve (12) years, Outdoor Coil and Parts –ten (10) years."; 16-1000-32, under "SINGLE PHASE R-410A OUTDOOR UNITS" and its "Registered Limited Warranty Period", for 4TTX, 4TTZ, 4TTV0, 4TWX, 4TWZ, 4TWV0, 4A6H6/7, 4A6Z, 4A6V0, 4A7A60xxE/G, 4A7A7, 4A7Z, 4A7V0: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years."; 16-1000-39, 26-1000-40, GW-658-4217 and GW-658-0119, under "SINGLE PHASE R-410A OUTDOOR UNITS" and its "Registered Limited Warranty Period", for 4TTX, 4TTV, 4TWX, 4TWV, 4A6H7, 4A6V, 4A7A7, 4A7V: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years."; GW-658-2032, under "SINGLE PHASE R-410A OUTDOOR UNITS" and its "Limited Warranty Period - Original Purchaser", for 4TTX, 4TTV, 4TWX, 4TWV, 4A6H7, 4A6V, 4A7A7, 4A7V: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years."; GW-OTDR-2201B, under "Single Phase R-410A Outdoor Units" and its "Registered Limited Warranty Period", for 4TTX, 4TTV, 4TWX, 4TWV, 4A6H6, 4A6H7, 4A6V, 4A7A6, 4A7A7, 4A7V: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years"; GW-OTDR-2401A, under "Single Phase Outdoor Units" and its "Registered Limited Warranty Period", for 4TTX, 5TTX, 4TTV, 5TTV, 4TWX, 5TWX, 4TWV, 5TWV, 4A6H6, 4A6H7, 5A6H7, 4A6V, 5A6V, 4A7A6, 4A7A7, 5A7A7, 4A7V, 5A7V: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years"; GW-OTDR-2401B, under "Single Phase Outdoor Units" and its "Registered Limited Warranty Period", for 4TTX, 5TTX, 4TTV, 5TTV, 4TWX, 5TWX, 4TWV, 5TWV, 4A6H6, 4A6H7, 5A6H7, 4A6V, 5A6V, 4A7A6, 4A7A7, 5A7A7, 4A7V, 5A7V, 5HPL6, 5HPL9, 5HCL6, 5HCL9: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years". Those that print a registered term give 10 years if registered within 60 days (16-1000-27 to GW-658-0119; GW-OTDR-2201B to GW-OTDR-2401B), on the models an edition lists. Each prints the manufacture dates it applies to, from 16-1000-27 (7/11) ("This limited warranty applies to Products manufactured on or after August 1, 2011.") to GW-OTDR-2401B (© 2024) ("This limited warranty applies to Products manufactured on or after March 1, 2024."). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. GW-658-2032 (no date printed) states what a later owner keeps in its transfer words; the result reads it when the owner is stated. None pays for labour.

Enter the serial above: each of these certificates prints the manufacture dates it applies to, so the result reads the held editions whose printed line reaches the unit's build month and works out the base parts term where they agree, each with the edition it rests on. Where the build month falls on a change of line, before the earliest line registered here, past the newest edition held, or under an edition that names one it replaces that is not held here, it says so and names what would answer it. Where those editions give the term only to the series they list, it also asks for the model number. Only the maker's records show whether a unit was registered.

Source: the maker's own limited warranty certificates, each identified by the part number printed on it; the serial result names the edition each term comes from, and the statute where a line quotes one.


Frequently Asked Questions

How old is my Trane unit?

Decode the serial number from the data plate. The dominant Trane format (2009 to present) is: 10+ characters starting with 2 digits; digits 1-2 = year, digits 3-4 = week. Example: 11241KADBB decodes to week 24 of 2011. Subtract the decoded year from the current year for the age.

Which brands share the Trane serial number format?

Trane is part of the Trane family, alongside American Standard and Ameristar. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.

Has the Trane serial decode been checked against serials somebody else dated?

Trane two-digit year (2009-present): Checked against 7 serials whose date a recall notice published by someone other than us states (CPSC recall notice 17-709, CPSC recall notice 25-369), 5 of them gas/electric packaged units, models 4YCZ50xx, across 2 equipment types. The date this tool reads first was consistent with the published window on all 7. Also read against 22 serials where a public body's own equipment schedule prints a year beside the serial (Winter Park, Florida; Norcross, Georgia; Wayne Township, New Jersey; the year sits under a column headed Year on 21, and in a row labelled Year Manufactured on 1, 21 of which the document does not define), 21 name an equipment type, 9 of them condensing unit, across 8 equipment types: 22 matched the reading shown first; and 2 serials where a seller entered a year in the listing's own year field or, for some, beside the serial in the listing's description on a government surplus listing for the serial (government surplus auction listings), 1 of them pallet of four HVAC units, across 2 equipment types: 2 matched the reading shown first; a seller's year is shown here for the record and is not counted toward this format's check.

Trane single-digit year (2002-2009): Checked against 3 serials whose date a recall notice published by someone other than us states (CPSC recall notice 05-104), 2-5 ton gas/electric packaged units, models YCP/YCX/YCY/YCZ. The date this tool reads first was consistent with the published window on all 3. Also read against 10 serials where a public body's own equipment schedule prints a year beside the serial (Norcross, Georgia; Salem, New Hampshire; Wayne Township, New Jersey; Winter Park, Florida; the year sits under a column headed Year on 6, in a row labelled Year Manufactured on 3, and on a line labelled YEAR on 1, 7 of which the document does not define), 7 name an equipment type, 4 of them condensing unit, across 4 equipment types: 10 matched the reading shown first. This format was also read against 1 serial on an air filtration system (CPSC recall notice 07-567): 1 matched the reading shown first. It is shown for the record and not counted toward this format's check, because the equipment is not a heating or cooling unit.

Trane letter-year (1980-2001): Checked against 2 serials whose date a recall notice published by someone other than us states (CPSC recall notice 01-507), Voyager series light commercial rooftop gas/electric units. The date this tool reads first was consistent with the published window on all 2. Also read against 2 serials where a public body's own equipment schedule prints a year beside the serial (Winter Park, Florida; Norcross, Georgia; the year sits under a column headed Year, which the document does not define), 1 of them condensing unit - heat pump, across 2 equipment types: 2 matched the reading shown first; and 1 serial where a seller entered a year in the listing's own year field on a government surplus listing for the serial (government surplus auction listings), XE1100 3-ton unit: 1 matched the reading shown first; a seller's year is shown here for the record and is not counted toward this format's check.

Across the Trane formats on this page, 7 serials with a date published outside this tool produced no reading at all (Winter Park, Florida; Wayne Township, New Jersey; government surplus auction listings). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.

What refrigerant does a Trane unit use?

By manufacture year: through 2005: R-22; 2006 to 2009: R-22 or R-410A; 2010 to 2024: R-410A; 2025 and later: R-454B. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.

How do I look up my Trane warranty?

The maker's own page: Trane's own warranty lookup, at www.trane.com. The page reads: "Put in a serial number connected to your registration to view warranty terms." This page reads no maker's records and cannot show whether a unit was registered. What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Trane warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit. 4 U.S. Consumer Product Safety Commission recall notices this tool matches name Trane equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.

Is my Trane unit still under warranty?

11 Trane and American Standard air conditioner and heat pump warranty certificate editions covering Trane are held here, from 16-1000-27 (7/11) to GW-OTDR-2401B (© 2024). The base parts term they print for their residential row differs by edition: 5 years (16-1000-27 to GW-658-0119; GW-OTDR-2201B to GW-OTDR-2401B) and 10 years (GW-658-2032); 16-1000-27, 16-1000-28, 16-1000-32, 16-1000-39, 26-1000-40, GW-658-4217 and GW-658-0119 give it only to the series their row lists, and the other rows they print are not registered here. Each also prints a compressor term of its own for some outdoor series: 16-1000-27 and 16-1000-28, under "SINGLE PHASE R410 OUTDOOR UNITS" and its "Registered Limited Warranty Period", for TRANE: 4TTZ0, 4TTX6, 4TTX5, 4TWZ0, 4TWX6, 4TWX5. ASD: 4A7Z0, 4A7A6, 4A6Z0, 4A6H6: "compressor – twelve (12) years, Outdoor Coil and Parts –ten (10) years."; 16-1000-32, under "SINGLE PHASE R-410A OUTDOOR UNITS" and its "Registered Limited Warranty Period", for 4TTX, 4TTZ, 4TTV0, 4TWX, 4TWZ, 4TWV0, 4A6H6/7, 4A6Z, 4A6V0, 4A7A60xxE/G, 4A7A7, 4A7Z, 4A7V0: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years."; 16-1000-39, 26-1000-40, GW-658-4217 and GW-658-0119, under "SINGLE PHASE R-410A OUTDOOR UNITS" and its "Registered Limited Warranty Period", for 4TTX, 4TTV, 4TWX, 4TWV, 4A6H7, 4A6V, 4A7A7, 4A7V: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years."; GW-658-2032, under "SINGLE PHASE R-410A OUTDOOR UNITS" and its "Limited Warranty Period - Original Purchaser", for 4TTX, 4TTV, 4TWX, 4TWV, 4A6H7, 4A6V, 4A7A7, 4A7V: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years."; GW-OTDR-2201B, under "Single Phase R-410A Outdoor Units" and its "Registered Limited Warranty Period", for 4TTX, 4TTV, 4TWX, 4TWV, 4A6H6, 4A6H7, 4A6V, 4A7A6, 4A7A7, 4A7V: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years"; GW-OTDR-2401A, under "Single Phase Outdoor Units" and its "Registered Limited Warranty Period", for 4TTX, 5TTX, 4TTV, 5TTV, 4TWX, 5TWX, 4TWV, 5TWV, 4A6H6, 4A6H7, 5A6H7, 4A6V, 5A6V, 4A7A6, 4A7A7, 5A7A7, 4A7V, 5A7V: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years"; GW-OTDR-2401B, under "Single Phase Outdoor Units" and its "Registered Limited Warranty Period", for 4TTX, 5TTX, 4TTV, 5TTV, 4TWX, 5TWX, 4TWV, 5TWV, 4A6H6, 4A6H7, 5A6H7, 4A6V, 5A6V, 4A7A6, 4A7A7, 5A7A7, 4A7V, 5A7V, 5HPL6, 5HPL9, 5HCL6, 5HCL9: "Compressor – twelve (12) years, Outdoor Coil, Parts – ten (10) years". Those that print a registered term give 10 years if registered within 60 days (16-1000-27 to GW-658-0119; GW-OTDR-2201B to GW-OTDR-2401B), on the models an edition lists. Each prints the manufacture dates it applies to, from 16-1000-27 (7/11) ("This limited warranty applies to Products manufactured on or after August 1, 2011.") to GW-OTDR-2401B (© 2024) ("This limited warranty applies to Products manufactured on or after March 1, 2024."). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. GW-658-2032 (no date printed) states what a later owner keeps in its transfer words; the result reads it when the owner is stated. None pays for labour. Enter the serial above: each of these certificates prints the manufacture dates it applies to, so the result reads the held editions whose printed line reaches the unit's build month and works out the base parts term where they agree, each with the edition it rests on. Where the build month falls on a change of line, before the earliest line registered here, past the newest edition held, or under an edition that names one it replaces that is not held here, it says so and names what would answer it. Where those editions give the term only to the series they list, it also asks for the model number. Only the maker's records show whether a unit was registered.

Why do some Trane serial numbers refuse to decode?

A nine-character Trane serial with a letter as its fourth character is not in the layout Trane's own date code page prints, where that character is the day of the week, a digit, so no date is read from it. Trane's page covers its residential and light commercial products; this tool holds no Trane serial chart for chillers or other applied equipment. Read the manufacture date off the data plate. In the year table Trane's own date code page prints for its residential and light commercial products and compressors, no year is printed for a first letter I, Q or V, and every letter that table does print, from O or A for 1980 to Z for 2001, is read by this tool. The same page has a separate table for Ducane oil and horizontal gas furnaces with letters of its own, including Q for 1984, which this tool does not read. Verify with the ANSI rating year printed on the data plate.

How old is my Trane furnace?

Trane's own Equipment Date Identification page dates the serial numbers "on all Trane central air conditioning and heating products"; it names gas furnaces only in its notes on dedicated horizontal gas furnaces. Enter the furnace's serial above: the result gives the date and age and says which document covers it, and that it covers furnaces by its scope. Trane's page reads a gas furnace built only for horizontal installation on a separate year column, so a serial opening with L, M, N, 85 to 89 or 9 is not called a furnace's age; on any other Trane furnace the page's own rule gives the date.


Related Tools

Same family, same decode rules: American Standard serial number lookup, Ameristar serial number lookup.

Different brand on the data plate?

The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.