Intry Verified receipt
Is the Intry Target Superheat Calculator accurate?
The provenance receipt for the Intry Target Superheat Calculator: the exact authority its values derive from, the edition they are keyed to, who has final say, and what our automated checks hold them against, rebuilt from their cited source.
The receipt
- Calculated from
- the locked CEC Title 24 RA3.2-2 charging table it was computed from, which agrees cell for cell with one manufacturer piston grid and runs a mean 4.77F above another, on the sixth of the table where any manufacturer check exists. Reused verbatim from the locked engine, never re-written for this page.
- Edition
- CEC Title 24 Table RA3.2-2
- Checked
- Before any release, an automated check runs the locked engine that produces these figures and holds its answers against values written from the source it cites, so a checked number answers to its source and not merely to itself. The check covers the cases someone wrote a check for, not every input the tool accepts: it tells you where a number comes from, and it is not a proof of every value. As of the current build that suite holds 30639 checks, and this page has to clear them too. This is our own deterministic gate, not a third-party audit.
- Runnable
- A reference engine behind the published numbers on this site. Runnable access is offered on the calculators exposed at the Intry MCP endpoint.
- Final say
- The manufacturer's charging chart for your exact fixed-orifice unit has final say, and where one exists it governs over this table.
Frequently Asked Questions
Is the Intry Target Superheat Calculator accurate?
It computes from the sources described below, and our automated checks hold its answers against values written from those sources for the cases the checks cover, not for every input you can enter. The manufacturer's charging chart for your exact fixed-orifice unit has final say, and where one exists it governs over this table. Every figure an Intry calculator computes comes from a locked source module, not hand-typed. 30639 automated checks, one suite for the whole site rather than a per-tool count, re-derive the numbers before each deploy from the tables this site transcribed from the locked CEC Title 24 RA3.2-2 charging table it was computed from, which agrees cell for cell with one manufacturer piston grid and runs a mean 4.77F above another, on the sixth of the table where any manufacturer check exists. This is our own deterministic gate, not a third-party audit. The per-tool receipt is public at https://www.intrysys.com/verified.