HVAC Serial Number Lookup

NuTone Serial Number Lookup: AC and Furnace Age

NuTone is part of the Nortek / Nordyne family, alongside Broan, Frigidaire, Gibson, Intertherm, Kelvinator, Mammoth, Maytag, Miller, Philco, Tappan, Westinghouse. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.

Quick answer: NuTone serial numbers (~1990s to present): 12 or 13 characters; characters 4-5 = year and 6-7 = month, both digits, with the leading three and the trailing five or six alphanumeric. Example: GBB030708229 = July 2003. The same rule covers Intertherm, Miller, Gibson, Frigidaire, Maytag, Westinghouse, Tappan, Broan, Kelvinator, Philco, and Mammoth.

Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.

7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. Some of the formats on this page are read from the manufacturer's own document; the others rest on secondary references, and each row below says which. A date stamped or printed on the data plate always outranks a serial decode.


NuTone Serial Number Formats

FormatEraExampleConfidence
12 or 13 characters; characters 4-5 = year and 6-7 = month, both digits, with the leading three and the trailing five or six alphanumericCross-checked across 2 secondary references, alongside 2 manufacturer documents held.~1990s to presentGBB030708229 = July 2003high
Three groups; the middle group is a letter + 4 digits, week then year (Rheem convention, built by Rheem for Nordyne)A single secondary reference, not a manufacturer document. Single source.older Rheem-built unitsMN3D102F38914228 = week 38 of 1991low

Worked Example: NuTone GBB030708229

Expected decode: July 2003. Character by character:

July 2003

GBB = plant/line prefix

03 = year 2003 (characters 4-5)

07 = July (characters 6-7)

08229 = week and sequence data


NuTone Refrigerant Timeline

Manufacture yearRefrigerant the years point toNotes
through 2009R-22Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22.
2010 to 2024R-410AFrom January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024.
2025 and laterR-454BNortek chose R-454B for the 2025 A2L transition, including the Intertherm/Miller manufactured-housing lines.

The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.


NuTone Warranty Terms

NuTone warranty lookup

No page of NuTone's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered.

What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the NuTone warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.

The NuTone warranty terms held here

5 Nortek air conditioner and heat pump warranty certificate editions covering NuTone are held here, from 708839H (12/15) to 10393380 (04/21). Every one prints a base parts term of 5 years for its residential row. Each gives 10 years if registered within 60 days (708839H to 10393380). Each prints the manufacture dates it applies to, from 708839H (12/15) ("Warranty effective for equipment manufactured after January 1, 2016.") to 10393380 (04/21) ("Warranty effective for equipment manufactured after July 1, 2019."). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Every one ties its registered term to the original owner; 10393380 (04/21) prints: "The upgraded registered warranty is not transferable." Every one gives its registered term only on further conditions it prints; 10393380 (04/21) prints: "Equipment that is not a properly Nortek Global HVAC matched system per manufacturer’s recommendations and the Air Conditioning Heating Refrigeration Institute (AHRI) would receive the unregistered warranty." Every one states what a later owner keeps in their transfer words; the result reads it when the owner is stated. None pays for labour.

Enter the serial above: each of these certificates prints the manufacture dates it applies to, so the result reads the held editions whose printed line reaches the unit's build month and works out the base parts term where they agree, each with the edition it rests on. Where the build month falls on a change of line, before the earliest line registered here, past the newest edition held, or under an edition that names one it replaces that is not held here, it says so and names what would answer it. Only the maker's records show whether a unit was registered.

Source: the maker's own limited warranty certificates, each identified by the part number printed on it; the serial result names the edition each term comes from, and the statute where a line quotes one.

The NuTone certificate editions held here

Each is listed by the identifier and the date or code printed on it. None of them is held here for another brand in NuTone's family.

  • 708839H (12/15): TEN YEAR LIMITED PARTS ONLY WARRANTY
  • 708839J (12/16): TEN YEAR LIMITED PARTS ONLY WARRANTY
  • 708839K (12/17): TEN YEAR LIMITED PARTS ONLY WARRANTY
  • 708839L (03/19): TEN YEAR LIMITED PARTS ONLY WARRANTY
  • 10393380 (04/21): TEN YEAR LIMITED PARTS ONLY WARRANTY

Frequently Asked Questions

How old is my NuTone unit?

Decode the serial number from the data plate. The dominant NuTone format (~1990s to present) is: 12 or 13 characters; characters 4-5 = year and 6-7 = month, both digits, with the leading three and the trailing five or six alphanumeric. Example: GBB030708229 decodes to July 2003. Subtract the decoded year from the current year for the age.

Which brands share the NuTone serial number format?

NuTone is part of the Nortek / Nordyne family, alongside Broan, Frigidaire, Gibson, Intertherm, Kelvinator, Mammoth, Maytag, Miller, Philco, Tappan, and Westinghouse. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.

Has the NuTone serial decode been checked against serials somebody else dated?

Nordyne/Nortek 12-character: Read against 1 serial where a public body's own equipment schedule prints a year beside the serial (Winter Park, Florida; the year sits under a column headed Year, which the document does not define), condensing unit: 1 matched the reading shown first.

No serial with a date published outside this tool has produced a reading through the Nordyne Rheem-built (middle date group) format yet. No document from the company that built the unit is held for it, so the rule rests on the secondary references this tool records.

Across the NuTone formats on this page, 1 serial with a date published outside this tool produced no reading at all (Mobile, Alabama). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.

What refrigerant does a NuTone unit use?

By manufacture year: through 2009: R-22; 2010 to 2024: R-410A; 2025 and later: R-454B. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.

How do I look up my NuTone warranty?

No page of NuTone's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered. What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the NuTone warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.

Is my NuTone unit still under warranty?

5 Nortek air conditioner and heat pump warranty certificate editions covering NuTone are held here, from 708839H (12/15) to 10393380 (04/21). Every one prints a base parts term of 5 years for its residential row. Each gives 10 years if registered within 60 days (708839H to 10393380). Each prints the manufacture dates it applies to, from 708839H (12/15) ("Warranty effective for equipment manufactured after January 1, 2016.") to 10393380 (04/21) ("Warranty effective for equipment manufactured after July 1, 2019."). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Every one ties its registered term to the original owner; 10393380 (04/21) prints: "The upgraded registered warranty is not transferable." Every one gives its registered term only on further conditions it prints; 10393380 (04/21) prints: "Equipment that is not a properly Nortek Global HVAC matched system per manufacturer’s recommendations and the Air Conditioning Heating Refrigeration Institute (AHRI) would receive the unregistered warranty." Every one states what a later owner keeps in their transfer words; the result reads it when the owner is stated. None pays for labour. Enter the serial above: each of these certificates prints the manufacture dates it applies to, so the result reads the held editions whose printed line reaches the unit's build month and works out the base parts term where they agree, each with the edition it rests on. Where the build month falls on a change of line, before the earliest line registered here, past the newest edition held, or under an edition that names one it replaces that is not held here, it says so and names what would answer it. Only the maker's records show whether a unit was registered.

How old is my NuTone furnace?

Nordyne's own Product Identifier sheet prints this serial layout beside its breakdown of a "Gas Furnace" model number. Enter the furnace's serial above: the result gives the date and age and says which document covers it.


Related Tools

Same family, same decode rules: Broan serial number lookup, Frigidaire serial number lookup, Gibson serial number lookup, Intertherm serial number lookup, Kelvinator serial number lookup, Mammoth serial number lookup, Maytag serial number lookup, Miller serial number lookup, Philco serial number lookup, Tappan serial number lookup, Westinghouse serial number lookup.

Different brand on the data plate?

The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.