HVAC Serial Number Lookup
Intertherm Serial Number Lookup: AC and Furnace Age
Intertherm is part of the Nortek / Nordyne family, alongside Broan, Frigidaire, Gibson, Kelvinator, Mammoth, Maytag, Miller, NuTone, Philco, Tappan, Westinghouse. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.
Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.
7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. Some of the formats on this page are read from the manufacturer's own document; the others rest on secondary references, and each row below says which. A date stamped or printed on the data plate always outranks a serial decode.
Intertherm furnace not heating?
Its stop checks come first, then what its light or code means, on furnace codes for Intertherm. Type what the furnace shows and it opens there with the brand filled in.
Intertherm Serial Number Formats
| Format | Era | Example | Confidence |
|---|---|---|---|
| 12 or 13 characters; characters 4-5 = year and 6-7 = month, both digits, with the leading three and the trailing five or six alphanumericCross-checked across 2 secondary references, alongside 2 manufacturer documents held. | ~1990s to present | GBB030708229 = July 2003 | high |
| Three groups; the middle group is a letter + 4 digits, week then year (Rheem convention, built by Rheem for Nordyne)A single secondary reference, not a manufacturer document. Single source. | older Rheem-built units | MN3D102F38914228 = week 38 of 1991 | low |
Worked Example: Intertherm GBB030708229
Expected decode: July 2003. Character by character:
GBB = plant/line prefix
03 = year 2003 (characters 4-5)
07 = July (characters 6-7)
08229 = week and sequence data
Intertherm serials from public records, dated
Each serial in the record tables below is listed under Intertherm in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026.
The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.
Mobile, Alabama: 1 serial; the decoder reads 0 of 1 as the year listed and does not decode 1
The record: PC60828394 803 Quigley House FCA 10-24-17.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| JSF0503038 | Split System | 2005 | No reading | Not decoded |
Winter Park, Florida: 1 serial; the decoder reads 1 of 1 as the year listed
The record: City operations energy audit 2023-09.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| JTF101000077 | Condensing Unit | 2010 | October 2010 | Same year |
Reading Intertherm model numbers
The Intertherm lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the tonnage decoder.
| Line | Example model | What the tonnage decoder reads | Document |
|---|---|---|---|
| Nortek SEER2 split system | FSA3BE4M1SN18K | 1.5 tons (18,000 BTU/h), an estimate | 837F-0822 |
| Nordyne SA1BF/SA2BF 16 SEER split air conditioner | FSA1BF4M1SN36K | 3 tons (36,000 BTU/h) | 10502330 |
| Nortek T4BE split system heat pump | T4BE-018K | 1.5 tons (18,000 BTU/h) | 7094080 |
CPSC recall notices naming Intertherm
Hazard, in the notice's words: “Heat exchangers in the furnace can crack.”
Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.
Intertherm Refrigerant Timeline
| Manufacture year | Refrigerant the years point to | Notes |
|---|---|---|
| through 2009 | R-22 | Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22. |
| 2010 to 2024 | R-410A | From January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024. |
| 2025 and later | R-454B | Nortek chose R-454B for the 2025 A2L transition, including the Intertherm/Miller manufactured-housing lines. |
The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.
Intertherm Warranty Terms
Intertherm warranty lookup
No page of Intertherm's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered.
Enter the serial in the lookup on this page for the build date and the unit's age. No Intertherm warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit.
One U.S. Consumer Product Safety Commission recall notice this tool matches names Intertherm equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
What this tool holds on Intertherm's warranty
Nortek's 2025 manufactured-housing certificate (equipment manufactured on or after January 1, 2025) gives 1 year on parts and 5 on the compressor. Registered with an AHRI-matched system within 60 days of installation, split-system outdoor units get 5 years on parts and 10 on the compressor, and package units 10 years on parts including the compressor. Nortek's 2019 certificate for site-built equipment prints different base terms, so the certificate for the unit's build year governs.
The result does not work out a dated term for Intertherm: no Intertherm certificate is registered for that here. Only the maker's records show whether a unit was registered.
Source: Nortek Global HVAC limited warranty certificates (2019 and 2025 editions, distributor copies).
Frequently Asked Questions
How old is my Intertherm unit?
Decode the serial number from the data plate. The dominant Intertherm format (~1990s to present) is: 12 or 13 characters; characters 4-5 = year and 6-7 = month, both digits, with the leading three and the trailing five or six alphanumeric. Example: GBB030708229 decodes to July 2003. Subtract the decoded year from the current year for the age.
Which brands share the Intertherm serial number format?
Intertherm is part of the Nortek / Nordyne family, alongside Broan, Frigidaire, Gibson, Kelvinator, Mammoth, Maytag, Miller, NuTone, Philco, Tappan, and Westinghouse. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.
Has the Intertherm serial decode been checked against serials somebody else dated?
Nordyne/Nortek 12-character: Read against 1 serial where a public body's own equipment schedule prints a year beside the serial (Winter Park, Florida; the year sits under a column headed Year, which the document does not define), condensing unit: 1 matched the reading shown first.
No serial with a date published outside this tool has produced a reading through the Nordyne Rheem-built (middle date group) format yet. No document from the company that built the unit is held for it, so the rule rests on the secondary references this tool records.
Across the Intertherm formats on this page, 1 serial with a date published outside this tool produced no reading at all (Mobile, Alabama). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.
What refrigerant does an Intertherm unit use?
By manufacture year: through 2009: R-22; 2010 to 2024: R-410A; 2025 and later: R-454B. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.
How do I look up my Intertherm warranty?
No page of Intertherm's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered. Enter the serial in the lookup on this page for the build date and the unit's age. No Intertherm warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit. One U.S. Consumer Product Safety Commission recall notice this tool matches names Intertherm equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
Is my Intertherm unit still under warranty?
Nortek's 2025 manufactured-housing certificate (equipment manufactured on or after January 1, 2025) gives 1 year on parts and 5 on the compressor. Registered with an AHRI-matched system within 60 days of installation, split-system outdoor units get 5 years on parts and 10 on the compressor, and package units 10 years on parts including the compressor. Nortek's 2019 certificate for site-built equipment prints different base terms, so the certificate for the unit's build year governs. The result does not work out a dated term for Intertherm: no Intertherm certificate is registered for that here. Only the maker's records show whether a unit was registered.
How old is my Intertherm furnace?
Nordyne's own Product Identifier sheet prints this serial layout beside its breakdown of a "Gas Furnace" model number. Enter the furnace's serial above: the result gives the date and age and says which document covers it.
Related Tools
HVAC Serial Number Lookup (All Brands)
The full decoder: 50+ brands across every major manufacturer family, with ambiguous formats shown honestly.
Tonnage From Model Number
The serial tells you the age; the model number tells you the size. Decode BTU capacity and tons from the model.
A2L Refrigerant Charge Limit Calculator
Replacing an old unit with R-454B or R-32 equipment? Check the room-size charge limits per UL 60335-2-40.
Same family, same decode rules: Broan serial number lookup, Frigidaire serial number lookup, Gibson serial number lookup, Kelvinator serial number lookup, Mammoth serial number lookup, Maytag serial number lookup, Miller serial number lookup, NuTone serial number lookup, Philco serial number lookup, Tappan serial number lookup, Westinghouse serial number lookup.
Different brand on the data plate?
The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.