HVAC Serial Number Lookup
Goodman Serial Number Lookup: AC and Furnace Age
Goodman is part of the Goodman family, alongside Amana. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.
Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.
Every serial format on this page is read from a document published by the company that built the unit, held as a retained copy. The manufacturer's document "Goodman Homeowner Extended Service Agreement", which states the rule "For most products". A date stamped or printed on the data plate always outranks a serial decode.
Goodman furnace not heating?
Its stop checks come first, then what its light or code means, on furnace codes for Goodman. Type what the furnace shows and it opens there with the brand filled in.
Goodman Serial Number Formats
| Format | Era | Example | Confidence |
|---|---|---|---|
| 10 digits; digits 1-2 = year, digits 3-4 = monthCross-checked across 4 secondary references, alongside a manufacturer document held. The manufacturer's document "Goodman Homeowner Extended Service Agreement", which states the rule "For most products". | Goodman since at least 1997; Janitrol 1982-1992; Daikin US unitary 2013+ | 9704011000 = April 1997 | high |
Some older or conflicting Goodman formats are recognized but deliberately not decoded; the decoder explains why when it sees one instead of guessing.
Worked Example: Goodman 9704011000
Expected decode: April 1997. Character by character:
97 = year 1997 (digits 1-2)
04 = April (digits 3-4)
011000 = production sequence
Goodman serials from public records, dated
Each serial in the record tables below is listed under Goodman in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026.
The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.
Winter Park, Florida: 43 serials; the decoder reads 40 of 43 as the year listed and does not decode 1
The records: City hall energy audit 2023-09, City operations energy audit 2023-09, East treatment plant energy audit 2023-09, Fire station 64 energy audit 2023-09, Magnolia water plant energy audit 2023-09, Tennis center tower energy audit 2023-09, Ward park energy audit 2023-09, Wellness place energy audit 2023-09, Fire station 62 energy audit 2023-09, Swoope water plant energy audit 2023-09.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| 1208657089 | Condensing Unit | 2012 | August 2012 | Same year |
| 1303263412 | Condensing Unit | 2013 | March 2013 | Same year |
| 1307287907 | Condensing Unit | 2013 | July 2013 | Same year |
| 1311397080 | Air Handling Unit | 2013 | November 2013 | Same year |
| 1401015968 | Condensing Unit | 2014 | January 2014 | Same year |
| 1406217153 | Air Handling Unit | 2014 | June 2014 | Same year |
| 1406402693 | Air Handling Unit | 2014 | June 2014 | Same year |
| 1407194105 | Condensing Unit | 2014 | July 2014 | Same year |
| 1409353423 | Condensing Unit | 2014 | September 2014 | Same year |
| 1501045102 | Air Handling Unit | 2015 | January 2015 | Same year |
| 1503043402 | Split System Condensing Unit | 2015 | March 2015 | Same year |
| 1503205300 | Air Handling Unit | 2015 | March 2015 | Same year |
| 1504245229 | Air Handling Unit | 2015 | April 2015 | Same year |
| 1510097813 | Air Handling Unit | 2015 | October 2015 | Same year |
| 1706531660 | Split System Air Conditioner | 2017 | June 2017 | Same year |
| 1812108133 | Condensing Unit | 2018 | December 2018 | Same year |
| 1901069969 | Condensing Unit | 2019 | January 2019 | Same year |
| 1901070286 | Condensing Unit | 2019 | January 2019 | Same year |
| 1901181280 | Condensing Unit | 2019 | January 2019 | Same year |
| 1901279780 | Air Handling Unit | 2019 | January 2019 | Same year |
| 1902290860 | Air Handler | 2019 | February 2019 | Same year |
| 1906359229 | Condensing Unit/Air Handling Unit | 2019 | June 2019 | Same year |
| 1907253709 | Air Handling Unit | 2019 | July 2019 | Same year |
| 1908009471 | Air Handling Unit | 2019 | August 2019 | Same year |
| 1908676665 | Air Handling Unit | 2019 | August 2019 | Same year |
| 1908708907 | Condensing Unit | 2019 | August 2019 | Same year |
| 1908727091 | Split System Heat Pump | 2019 | August 2019 | Same year |
| 1910101180 | Condensing Unit | 2019 | October 2019 | Same year |
| 1910279165 | Condensing Unit | 2019 | October 2019 | Same year |
| 1911724120 | Condensing Unit | 2019 | November 2019 | Same year |
| 19122729517 | Air Handling Unit | 2019 | No reading | Not decoded |
| 1912714640 | Air Handling Unit | 2019 | December 2019 | Same year |
| 1901070246 | Condensing Unit | 2020 | January 2019 | A different year |
| 1910200614 | Air Handling Unit | 2020 | October 2019 | A different year |
| 2001062973 | Condensing Unit | 2020 | January 2020 | Same year |
| 2001073815 | Air Handling Unit | 2020 | January 2020 | Same year |
| 2002228683 | Condensing Unit | 2020 | February 2020 | Same year |
| 2002240056 | Condensing Unit | 2020 | February 2020 | Same year |
| 2007122439 | Air Handler | 2020 | July 2020 | Same year |
| 2010326604 | Air Handler | 2020 | October 2020 | Same year |
| 2011002844 | Condensing Unit | 2020 | November 2020 | Same year |
| 2106689149 | Air Handling Unit | 2021 | June 2021 | Same year |
| 2202083630 | Condensing Unit | 2022 | February 2022 | Same year |
Norcross, Georgia: 9 serials; the decoder reads 6 of 9 as the year listed and does not decode 3
The record: Document Center file 8177.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| 0806003776 | Packaged Unit | 2008 | June 2008 | Same year |
| 0806341128 | Condensing Unit | 2008 | June 2008 | Same year |
| 0806341147 | Condensing Unit | 2008 | June 2008 | Same year |
| 0810195026 | Furnace | 2008 | October 2008 | Same year |
| 0810195027 | Furnace | 2008 | October 2008 | Same year |
| 805700203 | Furnace | 2008 | No reading | Not decoded |
| 806049728 | Condenser | 2008 | No reading | Not decoded |
| 806069638 | Furnace | 2008 | No reading | Not decoded |
| 1306195376 | Condensing Unit | 2013 | June 2013 | Same year |
Mobile, Alabama: 2 serials; the decoder reads 2 of 2 as the year listed
The record: PC60828394 360 Traffic Engineering FCA DRAFT 10-17-17.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| 1510140558 | AHU | 2015 | October 2015 | Same year |
| 1610145772 | AHU | 2016 | October 2016 | Same year |
Reading Goodman model numbers
The Goodman lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the Goodman tonnage page.
| Line | Example model | What the tonnage decoder reads | Document |
|---|---|---|---|
| Goodman GSC13/GSH13 R-22 split system | GSC130361AA | 3 tons (36,000 BTU/h) | SS-GSC13 |
| Goodman/Amana ASPT air handler | ASPT49D14AC | An air handler: 4 tons (48,000 BTU/h) | SS-GASPT |
| Goodman AWUF/AWUT wall-mount air handler | AWUF180516B | An air handler: 1.5 tons (18,000 BTU/h) | SS-GAWUF |
| Goodman GPGM3 packaged gas/electric unit (R-410A) | GPGM34808041 | A packaged unit: 4 tons (48,000 BTU/h) | SS-GPGM3 |
| Goodman GPGM3/GPDM3/GPUM3 packaged unit (R-32) | GPGM33608031AA | A packaged unit: 3 tons (36,000 BTU/h) | SS-GPGM3_GPUM3-R32 |
| Goodman GR9S/GD9S gas furnace | GR9S800603BN | A gas furnace: its size field is heating input, so no cooling tonnage is read | SS-GR9S80_GD9S80-R32 |
| Goodman PHKJ package heat pump | PHKJ024-1A | A packaged unit: identified; its maker's document prints no model number legend, so no size is read | RP - 234J |
CPSC recall notices naming Goodman
Hazard, in the notice's words: “A power interruption in the heat pump can result in the product providing heat when the power resumes, despite the thermostat being in cooling mode, posing a risk of excessive heat exposure to consumers.”
Hazard, in the notice's words: “The labels found on the serial plate have incorrect electrical information that could result in installers and servicers using undersized wiring or incorrect fuse/circuit breaker parts, posing a fire hazard.”
Hazard, in the notice's words: “The blower motor is not grounded, posing an electrical shock hazard to individuals servicing the units”
Hazard, in the notice's words: “The pull-out disconnects may not disable power to the air handler, posing an electrical shock hazard to individuals servicing the units.”
Hazard, in the notice's words: “The serial plates on the units contain inaccurate information that could result in the use of undersized installation wiring, posing a fire hazard.”
Hazard, in the notice's words: “Heat exchangers in the furnace can crack.”
Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.
Goodman Refrigerant Timeline
| Manufacture year | Refrigerant the years point to | Notes |
|---|---|---|
| through 1995 | R-22 | R-22 was the standard refrigerant for equipment of this age. R-410A did not become an EPA-accepted substitute for HCFC-22 in household and light commercial air conditioning until February 8, 1996, so a unit built before then predates it. Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22. |
| 1996 to 2009 | R-22 or R-410A | Goodman sold both in the 2000s: GSC-prefix models are R-22, GSX-prefix models are R-410A. Decode from the model letter, not the year alone. |
| 2010 to 2023 | R-410A | From January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024. |
| 2024 | R-410A or R-32 | Goodman's R-32 lines (GLXS/GLZS prefixes) started production mid-2024 while R-410A production wound down. The model prefix decides. |
| 2025 and later | R-32 | Goodman and Amana chose R-32 (not R-454B) for the A2L transition under Daikin's R-32 commitment. |
The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.
Goodman Warranty Terms
Goodman warranty lookup
The maker's own page: Goodman's own warranty lookup, at warranty.goodmanmfg.com. The page is headed "Warranty Lookup" and asks for the serial, the model and the last name. This page reads no maker's records and cannot show whether a unit was registered. Open Goodman's own warranty lookup
What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Goodman warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.
6 U.S. Consumer Product Safety Commission recall notices this tool matches name Goodman equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
The Goodman warranty terms held here
8 Goodman family air conditioner and heat pump warranty certificate editions covering Goodman are held here, from PWGACHPKD (9/2014) to PWGACHPMTSDC (12/2025). Every one prints a base parts term of 5 years for its residential row. Each gives 10 years if registered within 60 days (PWGACHPKD to PWGACHPMTSDC). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them tie their terms to the original owner; PWCACHPTC (6/2015) prints: "This warranty only covers the original owner of the residence as of the installation date (as defined below), and his or her spouse". PWGACHPKD prints a lifetime compressor term with its own conditions; no compressor end is worked out here. None pays for labour.
Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. Only the maker's records show whether a unit was registered.
Source: the maker's own limited warranty certificates, each identified by the part number printed on it; the serial result names the edition each term comes from, and the statute where a line quotes one.
The Goodman certificate editions held here
Each is listed by the identifier and the date or code printed on it. None of them is held here for another brand in Goodman's family.
- PWGACHPKD (9/2014): LIMITED WARRANTY
- PWCACHPTC (6/2015): LIMITED WARRANTY
- PWGACHPKQ (7/2020): LIMITED WARRANTY
- PWGACHPTTYURB (06/2022): LIMITED WARRANTY
- PWGACHPR3BOD (07/2024): LIMITED WARRANTY
- PWGACHPTSMTD (04/2025): LIMITED WARRANTY
- PWGACHPR3BODA (11/2025): LIMITED WARRANTY
- PWGACHPMTSDC (12/2025): LIMITED WARRANTY
Frequently Asked Questions
How old is my Goodman unit?
Decode the serial number from the data plate. The dominant Goodman format (since at least 1997) is: 10 digits; digits 1-2 = year, digits 3-4 = month. Example: 9704011000 decodes to April 1997. Subtract the decoded year from the current year for the age.
Which brands share the Goodman serial number format?
Goodman is part of the Goodman family, alongside Amana. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.
Has the Goodman serial decode been checked against serials somebody else dated?
Goodman family 10-digit (YYMM): Checked against 10 serials whose date a recall notice published by someone other than us states (CPSC recall notice 08-602, CPSC recall notice 17-103, CPSC recall notice 18-113, CPSC recall notice 22-021), 4 of them air handlers, models AWUF and ACNF, across 4 equipment types. The date this tool reads first was consistent with the published window on all 10. Also read against 56 serials where a public body's own equipment schedule prints a year beside the serial (Norcross, Georgia; Winter Park, Florida; Mobile, Alabama; the year sits under a column headed Year on 53, and under a column headed Year Manuf on 3, 53 of which the document does not define), 24 of them condensing unit, across 11 equipment types: 54 matched the reading shown first, 2 did not match any reading (the published year ran later than this tool's reading on all 2); and 2 serials where a seller entered a year in the listing's own year field on a government surplus listing for the serial (government surplus auction listings), 1 of them CAPF4961C6DB coil in two-unit lot, across 2 equipment types: 2 did not match any reading (the published year ran later than this tool's reading on all 2); a seller's year is shown here for the record and is not counted toward this format's check.
Across the Goodman format on this page, 26 serials with a date published outside this tool produced no reading at all (Winter Park, Florida; Norcross, Georgia; Hawaii State Department of Education). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.
Where someone outside this tool wrote down a different year for a unit, that year is shown here rather than dropped. It is that publisher's record for the unit, and a schedule or a listing can carry a replacement, system or lot year rather than the build year. The MFG DATE on the unit's data plate is the build date.
What refrigerant does a Goodman unit use?
By manufacture year: through 1995: R-22; 1996 to 2009: R-22 or R-410A; 2010 to 2023: R-410A; 2024: R-410A or R-32; 2025 and later: R-32. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.
How do I look up my Goodman warranty?
The maker's own page: Goodman's own warranty lookup, at warranty.goodmanmfg.com. The page is headed "Warranty Lookup" and asks for the serial, the model and the last name. This page reads no maker's records and cannot show whether a unit was registered. What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Goodman warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit. 6 U.S. Consumer Product Safety Commission recall notices this tool matches name Goodman equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
Is my Goodman unit still under warranty?
8 Goodman family air conditioner and heat pump warranty certificate editions covering Goodman are held here, from PWGACHPKD (9/2014) to PWGACHPMTSDC (12/2025). Every one prints a base parts term of 5 years for its residential row. Each gives 10 years if registered within 60 days (PWGACHPKD to PWGACHPMTSDC). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them tie their terms to the original owner; PWCACHPTC (6/2015) prints: "This warranty only covers the original owner of the residence as of the installation date (as defined below), and his or her spouse". PWGACHPKD prints a lifetime compressor term with its own conditions; no compressor end is worked out here. None pays for labour. Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. Only the maker's records show whether a unit was registered.
Why do some Goodman serial numbers refuse to decode?
This is a legacy Goodman format ending in P or D, which secondary references tie to PTAC and older units. Published sources conflict on which position is the year and which is the month, so this tool will not guess. Check the data plate or the installation paperwork.
How old is my Goodman furnace?
Goodman's own limited warranty for the gas furnace models it lists prints "The first four digits of the serial number (YYMM) on the unit indicate the manufacture date."; it is a current certificate, lists its models rather than the word furnace, and the tool reads an older unit's serial by the same rule. Enter the furnace's serial above: the result gives the date and age and says which document covers it, and that it covers furnaces by its scope.
Related Tools
HVAC Serial Number Lookup (All Brands)
The full decoder: 50+ brands across every major manufacturer family, with ambiguous formats shown honestly.
Tonnage From Model Number
The serial tells you the age; the model number tells you the size. Decode BTU capacity and tons from the model.
A2L Refrigerant Charge Limit Calculator
Replacing an old unit with R-454B or R-32 equipment? Check the room-size charge limits per UL 60335-2-40.
Same family, same decode rules: Amana serial number lookup.
Different brand on the data plate?
The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.