HVAC Serial Number Lookup

Amana Serial Number Lookup: AC and Furnace Age

Amana is part of the Goodman family, alongside Goodman. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.

Quick answer: Amana serial numbers (since 1997, when Goodman took over Amana production): 10 digits; digits 1-2 = year, digits 3-4 = month. Example: 9704011000 = April 1997. The same rule covers Goodman, Janitrol, and Daikin.

Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.

7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. These rules rest on secondary references rather than on a document from the company that built the unit. Where two or more cover the same format we cross-check them against each other. A date stamped or printed on the data plate always outranks a serial decode.

Amana furnace not heating?

Its stop checks come first, then what its light or code means, on furnace codes for Amana. Type what the furnace shows and it opens there with the brand filled in.


Amana Serial Number Formats

FormatEraExampleConfidence
10 digits; digits 1-2 = year, digits 3-4 = monthCross-checked across 4 secondary references, not a manufacturer document. The manufacturer prints this rule for a narrower product in "Amana Brand Commercial Limited Warranty, Packaged Terminal Products", which states it for "PACKAGED TERMINAL PRODUCTS"; that document does not cover every unit of this brand.Goodman since at least 1997; Janitrol 1982-1992; Daikin US unitary 2013+9704011000 = April 1997high

Some older or conflicting Amana formats are recognized but deliberately not decoded; the decoder explains why when it sees one instead of guessing.


Worked Example: Amana 9704011000

Expected decode: April 1997. Character by character:

April 1997

97 = year 1997 (digits 1-2)

04 = April (digits 3-4)

011000 = production sequence

Amana serials from public records, dated

Each serial in the record tables below is listed under Amana in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026.

The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.

Norcross, Georgia: 3 serials; the decoder reads 2 of 3 as the year listed and does not decode 1

The record: Document Center file 8177.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
0806069885AHU2008June 2008Same year
0806069886Air handler2008June 2008Same year
808741363Furnace2008No readingNot decoded

Reading Amana model numbers

The Amana lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the Amana tonnage page.

Each line is identified from the maker document in its Document column. The example is a model in that line's layout, and the reading is what the tonnage decoder returns for it.
LineExample modelWhat the tonnage decoder readsDocument
Goodman/Amana ASPT air handlerASPT49D14ACAn air handler: 4 tons (48,000 BTU/h)SS-AASPT
Amana VTACAVH093H25AXXXAn Amana VTAC single package vertical unit: 0.75 tons (9,000 BTU/h)MC-VTAC 10-20

CPSC recall notices naming Amana

Recall 24-286 · 2024-06-27

Hazard, in the notice's words: “A power interruption in the heat pump can result in the product providing heat when the power resumes, despite the thermostat being in cooling mode, posing a risk of excessive heat exposure to consumers.”

Recall 18-115 · 2018-03-05

Hazard, in the notice's words: “The labels found on the serial plate have incorrect electrical information that could result in installers and servicers using undersized wiring or incorrect fuse/circuit breaker parts, posing a fire hazard.”

Recall 17-145 · 2017-05-02

Hazard, in the notice's words: “The blower motor is not grounded, posing an electrical shock hazard to individuals servicing the units”

Recall 13-715 · 2013-01-04

Hazard, in the notice's words: “The serial plates on the units have inaccurate information that could result in installers and servicers using undersized wiring, posing a fire hazard.”

Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.


Amana Refrigerant Timeline

Manufacture yearRefrigerant the years point toNotes
through 1995R-22R-22 was the standard refrigerant for equipment of this age. R-410A did not become an EPA-accepted substitute for HCFC-22 in household and light commercial air conditioning until February 8, 1996, so a unit built before then predates it. Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22.
1996 to 2009R-22 or R-410AGoodman sold both in the 2000s: GSC-prefix models are R-22, GSX-prefix models are R-410A. Decode from the model letter, not the year alone.
2010 to 2023R-410AFrom January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024.
2024R-410A or R-32Goodman's R-32 lines (GLXS/GLZS prefixes) started production mid-2024 while R-410A production wound down. The model prefix decides.
2025 and laterR-32Goodman and Amana chose R-32 (not R-454B) for the A2L transition under Daikin's R-32 commitment.

The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.


Amana Warranty Terms

Amana warranty lookup

The maker's own page: Amana's own warranty lookup (run by Goodman), at warranty.goodmanmfg.com. The page is headed "Warranty Lookup" and asks for the serial, the model and the last name. This page reads no maker's records and cannot show whether a unit was registered. Open Amana's own warranty lookup (run by Goodman)

What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Amana warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.

4 U.S. Consumer Product Safety Commission recall notices this tool matches name Amana equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.

The Amana warranty terms held here

4 Goodman family air conditioner and heat pump warranty certificate editions covering Amana are held here, from PWAACHPPH (2/2015) to PWAACHPR3BODA (11/2025). Every one prints a base parts term of 5 years for its residential row. Each gives 10 years if registered within 60 days (PWAACHPPH to PWAACHPR3BODA). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them tie its terms to the original owner; PWAACHPPH (2/2015) prints: "This warranty only covers the original owner of the residence as of the installation date (as defined below), and his or her spouse". None pays for labour.

Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. Only the maker's records show whether a unit was registered.

Source: the maker's own limited warranty certificates, each identified by the part number printed on it; the serial result names the edition each term comes from, and the statute where a line quotes one.

The Amana certificate editions held here

Each is listed by the identifier and the date or code printed on it. None of them is held here for another brand in Amana's family.

  • PWAACHPPH (2/2015): LIMITED WARRANTY
  • PWAACHPLZ (04/2025): LIMITED WARRANTY
  • PWAOTACHP23LTD (04/2025): LIMITED WARRANTY
  • PWAACHPR3BODA (11/2025): LIMITED WARRANTY

Frequently Asked Questions

How old is my Amana unit?

Decode the serial number from the data plate. The dominant Amana format (since 1997, when Goodman took over Amana production) is: 10 digits; digits 1-2 = year, digits 3-4 = month. Example: 9704011000 decodes to April 1997. Subtract the decoded year from the current year for the age.

Which brands share the Amana serial number format?

Amana is part of the Goodman family, alongside Goodman. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.

Has the Amana serial decode been checked against serials somebody else dated?

Goodman family 10-digit (YYMM): Checked against 10 serials whose date a recall notice published by someone other than us states (CPSC recall notice 08-602, CPSC recall notice 17-103, CPSC recall notice 18-113, CPSC recall notice 22-021), 4 of them air handlers, models AWUF and ACNF, across 4 equipment types. The date this tool reads first was consistent with the published window on all 10. Also read against 56 serials where a public body's own equipment schedule prints a year beside the serial (Norcross, Georgia; Winter Park, Florida; Mobile, Alabama; the year sits under a column headed Year on 53, and under a column headed Year Manuf on 3, 53 of which the document does not define), 24 of them condensing unit, across 11 equipment types: 54 matched the reading shown first, 2 did not match any reading (the published year ran later than this tool's reading on all 2); and 2 serials where a seller entered a year in the listing's own year field on a government surplus listing for the serial (government surplus auction listings), 1 of them CAPF4961C6DB coil in two-unit lot, across 2 equipment types: 2 did not match any reading (the published year ran later than this tool's reading on all 2); a seller's year is shown here for the record and is not counted toward this format's check.

Across the Amana format on this page, 26 serials with a date published outside this tool produced no reading at all (Winter Park, Florida; Norcross, Georgia; Hawaii State Department of Education). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.

Where someone outside this tool wrote down a different year for a unit, that year is shown here rather than dropped. It is that publisher's record for the unit, and a schedule or a listing can carry a replacement, system or lot year rather than the build year. The MFG DATE on the unit's data plate is the build date.

What refrigerant does an Amana unit use?

By manufacture year: through 1995: R-22; 1996 to 2009: R-22 or R-410A; 2010 to 2023: R-410A; 2024: R-410A or R-32; 2025 and later: R-32. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.

How do I look up my Amana warranty?

The maker's own page: Amana's own warranty lookup (run by Goodman), at warranty.goodmanmfg.com. The page is headed "Warranty Lookup" and asks for the serial, the model and the last name. This page reads no maker's records and cannot show whether a unit was registered. What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Amana warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit. 4 U.S. Consumer Product Safety Commission recall notices this tool matches name Amana equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.

Is my Amana unit still under warranty?

4 Goodman family air conditioner and heat pump warranty certificate editions covering Amana are held here, from PWAACHPPH (2/2015) to PWAACHPR3BODA (11/2025). Every one prints a base parts term of 5 years for its residential row. Each gives 10 years if registered within 60 days (PWAACHPPH to PWAACHPR3BODA). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them tie its terms to the original owner; PWAACHPPH (2/2015) prints: "This warranty only covers the original owner of the residence as of the installation date (as defined below), and his or her spouse". None pays for labour. Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. Only the maker's records show whether a unit was registered.

Why do some Amana serial numbers refuse to decode?

This is a legacy Goodman format ending in P or D, which secondary references tie to PTAC and older units. Published sources conflict on which position is the year and which is the month, so this tool will not guess. Check the data plate or the installation paperwork.

How old is my Amana furnace?

Amana's own limited warranty for the gas furnace models it lists prints "The first four digits of the serial number (YYMM) on the unit indicate the manufacture date."; it is a current certificate, lists its models rather than the word furnace, and the tool reads an older unit's serial by the same rule. Enter the furnace's serial above: the result gives the date and age and says which document covers it, and that it covers furnaces by its scope.