HVAC Serial Number Lookup

Bryant Serial Number Lookup

Bryant is part of the Carrier family, alongside Carrier, Payne. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.

Quick answer: Bryant serial numbers (~1980 to present): 4 digits + letter + 4-6 digits; digits 1-2 = week, digits 3-4 = year, the letter is a plant code. Example: 0709G10932 = week 7 of 2009 (Bryant). The same rule covers Carrier, Payne, and Day & Night.

Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.

7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. Some of the formats on this page are read from the manufacturer's own document; the others rest on secondary references, and each row below says which. A date stamped or printed on the data plate always outranks a serial decode.

Bryant furnace not heating?

Its stop checks come first, then what its light or code means, on furnace codes for Bryant. Type what the furnace shows and it opens there with the brand filled in.


Bryant Serial Number Formats

FormatEraExampleConfidence
4 digits + letter + 4-6 digits; digits 1-2 = week, digits 3-4 = year, the letter is a plant codeCross-checked across 3 secondary references, alongside 2 manufacturer documents held.~1980 to present4006A17330 = week 40 of 2006high
9-10 digits, no letters; digits 1-2 = year, digits 3-4 = monthA single secondary reference, not a manufacturer document.1980s (BDP-built units)850304091 = March 1985medium
8 characters; US units start month letter (M-Z, skipping O and U) then year digit 0-4, Canadian units reverse the first twoA single secondary reference, not a manufacturer document. Month letter table single-sourced; year digit is solid.1980 to 1984W4D14008 = September 1984low
Letter A-L + year digit + 5-6 digit sequence; A = January through L = DecemberCross-checked across 2 secondary references, not a manufacturer document.1969 to 1979A167890 = January 1971medium

Some older or conflicting Bryant formats are recognized but deliberately not decoded; the decoder explains why when it sees one instead of guessing.


Worked Example: Bryant 0709G10932

Expected decode: week 7 of 2009 (Bryant). Character by character:

Week 7 of 2009 (about February)

07 = week 7 of the year (digits 1-2)

09 = year 2009 (digits 3-4)

G = plant/assembly code, 10932 = production sequence

Carrier-family serials are week-first. ICP brands (Heil, Tempstar) use the same visual layout with year first; the brand on the nameplate decides which reading applies.

Reading Bryant model numbers

The Bryant lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the tonnage decoder.

Each line is identified from the maker document in its Document column. The example is a model in that line's layout, and the reading is what the tonnage decoder returns for it.
LineExample modelWhat the tonnage decoder readsDocument
Bryant 310AAV/310JAV gas furnace310AAV066135A gas furnace: its size field is heating input, so no cooling tonnage is readPDS310A-11

CPSC recall notices naming Bryant

Recall 20-009 · 2019-10-10

Hazard, in the notice's words: “The fan motor on the heat pumps can fail, causing the units to overheat, posing a fire hazard.”

Recall 17-150 · 2017-05-11

Hazard, in the notice's words: “The capacitors in the fuse boards in the heat pumps can stop working causing the unit to overheat, posing a fire hazard.”

Recall 97-012 · 1996-10-29

Hazard, in the notice's words: “Heat exchangers in the furnace can crack.”

Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.


Bryant Refrigerant Timeline

Manufacture yearRefrigerant the years point toNotes
through 1995R-22Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22.
1996 to 2009R-22 or R-410A (Puron)Carrier launched Puron (R-410A) in 1996, the first residential R-410A line, so units in this window can be either. The model series on the data plate is the reliable signal, not the year.
2010 to 2024R-410AFrom January 1, 2010, EPA allowed new R-22 to be produced or imported only for use in equipment manufactured before that date; R-410A was the standard through 2024.
2025 and laterR-454B (Puron Advance)From January 1, 2025 EPA's rule bars installing a new residential split system at 700 GWP or above unless all of its specified components (condensing unit, condenser, compressor, evaporator unit and evaporator, 40 CFR 84.52) were made or imported before that date (40 CFR 84.54(c)(1)), and R-410A components may still be made, so check the data plate on 2024-25 builds: both fluids shipped in that changeover.

The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.


Bryant Warranty Terms

Bryant warranty lookup

The maker's own page: Bryant's own product registration page, at productregistration.bryant.com. The page reads: "Register all of your new BRYANT equipment." This page reads no maker's records and cannot show whether a unit was registered. Open Bryant's own product registration page

What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Bryant warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit.

3 U.S. Consumer Product Safety Commission recall notices this tool matches name Bryant equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.

The Bryant warranty terms held here

5 Carrier family air conditioner and heat pump warranty certificate editions covering Bryant are held here, from 39004DP363 (06/08) to ACHP-B454-01WAR (Edition Date: 11/23). Every one prints a base parts term of 5 years for its residential row. Those that print a registered term give 10 years if registered within 90 days (39004DP529 to ACHP-B454-01WAR). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them print a separate term for a later owner, in a Subsequent Owners column; the result reads it when the owner is stated. None pays for labour.

Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. Only the maker's records show whether a unit was registered.

Source: the maker's own limited warranty certificates, each identified by the part number printed on it; the serial result names the edition each term comes from, and the statute where a line quotes one.

The Bryant certificate editions held here

Each is listed by the identifier and the date or code printed on it. None of them is held here for another brand in Bryant's family.

  • 39004DP363 (06/08): Limited Warranty for Single Phase Evolution, Preferred, and Legacy Line, Outdoor Cooling or Heating-Cooling Product of 60,000 BTUH or less Cooling Capacity
  • 39004DP529 (01/2015): Limited Warranty for Air Conditioner & Heat Pump Condensing Units with Puron® (R-410A) Refrigerant
  • 39004BY004 (01/2020): Limited Warranty for Air Conditioner & Heat Pump Condensing Units with Puron® (R-410A) Refrigerant
  • ACHP-B-01WAR (06/22): Limited Warranty for Air Conditioner & Heat Pump Condensing Units with Puron® (R-410A) Refrigerant
  • ACHP-B454-01WAR (Edition Date: 11/23): Limited Warranty for Air Conditioner & Heat Pump Condensing Units with Puron Advance® (R-454B) Refrigerant

Frequently Asked Questions

How old is my Bryant unit?

Decode the serial number from the data plate. The dominant Bryant format (~1980 to present) is: 4 digits + letter + 4-6 digits; digits 1-2 = week, digits 3-4 = year, the letter is a plant code. Example: 0709G10932 decodes to week 7 of 2009 (Bryant). Subtract the decoded year from the current year for the age.

Which brands share the Bryant serial number format?

Bryant is part of the Carrier family, alongside Carrier and Payne. These brands come off shared production lines with the same data plates, so this page's serial number formats apply across the family. The refrigerant timeline above is stated for the whole family, not per brand. The warranty section above is this brand's own.

Has the Bryant serial decode been checked against serials somebody else dated?

Carrier family week-year (WWYY + plant letter): Checked against 10 serials whose date a recall notice published by someone other than us states (CPSC recall notice 18-731, CPSC recall notice 02-227), 8 of them 7,000 BTU window air conditioner, model 77ZFA007101, across 2 equipment types. The date this tool reads first was consistent with the published window on all 10. Also read against 186 serials where a public body's own equipment schedule prints a year beside the serial (Norcross, Georgia; Salem, New Hampshire; Winter Park, Florida; Wayne Township, New Jersey; Redondo Beach Unified School District; the year sits under a column headed Year Installed on 98, under a column headed Year on 63, in a row labelled Year Manufactured on 18, and on a line labelled YEAR on 7, 70 of which the document does not define), 168 name an equipment type, 92 of them furnace, across 12 equipment types: 185 matched the reading shown first, 1 did not match any reading (the published year ran earlier than this tool's reading). This format was also read against 1 serial on a chiller (Winter Park, Florida): 1 matched the reading shown first. It is shown for the record and not counted toward this format's check, because the equipment is not a heating or cooling unit.

No serial with a date published outside this tool has produced a reading through the Carrier family 1980s all-numeric (YYMM), Carrier family 1980-1984 (month letter + year digit), and Carrier family 1969-1979 (month letter A-L + year digit) formats yet. No document from the company that built the unit is held for them, so those rules rest on the secondary references this tool records.

Across the Bryant formats on this page, 4 serials with a date published outside this tool produced no reading at all (Norcross, Georgia; Salem, New Hampshire). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.

Where someone outside this tool wrote down a different year for a unit, that year is shown here rather than dropped. It is that publisher's record for the unit, and a schedule or a listing can carry a replacement, system or lot year rather than the build year. The MFG DATE on the unit's data plate is the build date.

What refrigerant does a Bryant unit use?

By manufacture year: through 1995: R-22; 1996 to 2009: R-22 or R-410A (Puron); 2010 to 2024: R-410A; 2025 and later: R-454B (Puron Advance). The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.

How do I look up my Bryant warranty?

The maker's own page: Bryant's own product registration page, at productregistration.bryant.com. The page reads: "Register all of your new BRYANT equipment." This page reads no maker's records and cannot show whether a unit was registered. What this page works out is the next question. Enter the serial in the lookup on this page and the result works out the parts term the Bryant warranty certificates held here print for that build date, naming the edition and quoting its clause, or says plainly why it cannot and what would answer it. It asks only for answers that would change a line it shows, each naming the line it moves, and a Service Brief carries the result to whoever works on the unit. 3 U.S. Consumer Product Safety Commission recall notices this tool matches name Bryant equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.

Is my Bryant unit still under warranty?

5 Carrier family air conditioner and heat pump warranty certificate editions covering Bryant are held here, from 39004DP363 (06/08) to ACHP-B454-01WAR (Edition Date: 11/23). Every one prints a base parts term of 5 years for its residential row. Those that print a registered term give 10 years if registered within 90 days (39004DP529 to ACHP-B454-01WAR). They start the term at installation, or at a date counted from manufacture when installation cannot be shown. Some of them print a separate term for a later owner, in a Subsequent Owners column; the result reads it when the owner is stated. None pays for labour. Enter the serial above: where held editions placed at the build, or at the install month given (by a printed date before the build, or by a printed line making them effective for installs from that month or earlier), and dated after the build agree, the result works out the base parts term from the build date and the dated windows, each with the edition it rests on; where not, it says so and names what would answer it. Only the maker's records show whether a unit was registered.

Why do some Bryant serial numbers refuse to decode?

A secondary reference dates this Bryant/Carrier style (week digits + a year letter) to 1960 to 1979. This tool holds one source for the year-letter chart, so this tool does not decode it.

How old is my Bryant furnace?

No maker document held here dates Bryant furnaces, so the tool does not call a date a Bryant furnace's age; it reads the serial by the same rule it uses for Bryant's other equipment.


Related Tools

Same family, same decode rules: Carrier serial number lookup, Payne serial number lookup.

Different brand on the data plate?

The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.