HVAC · Air side

A 8 in round duct carries about 212 CFM

The airflow a 8 in round duct carries at the common 0.08 in. wc per 100 ft residential friction rate, galvanized steel, standard air, before friction and noise pass the design target. Computed from the Darcy-Colebrook duct model, not looked up.

Field brief
8 in roundcarries about 212 CFM at 0.08 in. wc/100 ft before friction and noise climb past the residential target.212 CFM

8 in duct airflow (0.08 in. wc/100 ft)

Computed from the ASHRAE / ACCA Manual D equal-friction model (Darcy-Weisbach with a Colebrook-White friction factor, galvanized roughness 0.0003 ft), galvanized steel, standard air.
PropertyValue
Round size8 in
Max airflow at 0.08~212 CFM
Friction target0.08 in. wc/100 ft

These are static reference figures at the residential design rate. For your own airflow and friction rate, run the interactive duct size calculator, or convert a shape with the round-to-rectangular converter.


FAQs

How many CFM does a 8 inch duct carry?

A 8 in round duct carries about 212 CFM at the common 0.08 in. wc per 100 ft friction rate (galvanized steel, standard air). Push more air through it and the velocity and friction climb past the residential target, which is where duct noise starts.

Is a 8 inch duct big enough for my run?

It depends on the airflow the room needs. A 8 in round is right up to about 212 CFM at 0.08 in. wc per 100 ft; above that, step up to the next size. Enter your actual CFM in the duct size calculator to confirm.

What friction rate is this based on?

0.08 in. wc per 100 ft, the standard residential design target that ACCA Manual D Appendix 3 tables assume. A higher target lets a given duct carry more air at the cost of more velocity and noise.