Is the Intry Furnace Temperature Rise Calculator accurate?
The provenance receipt for the Intry Furnace Temperature Rise Calculator: the exact authority its values derive from, the edition they are keyed to, who has final say, and what our automated checks hold them against.
The receipt
- Calculated from
- Your unit's rating plate (the temperature rise range) · Carrier Service and Technical Support Manual 440 04 4321 10, gas furnace (F/G)9MXT · Velocity Boiler Works Installer's Information Manual 431570g, Section 20 · The sensible-heat relation, for the airflow figure only · 10 CFR 430.2, for what AFUE is and is not. Reused word for word from the locked engine, never re-written for this page. The documents it rests on are listed in the source receipt on the tool page.
- Edition
- not a code table
- What it reads
- Your unit's rating plate (the temperature rise range)
- Carrier Service and Technical Support Manual 440 04 4321 10, gas furnace (F/G)9MXT
- Velocity Boiler Works Installer's Information Manual 431570g, Section 20
- The sensible-heat relation, for the airflow figure only
- 10 CFR 430.2, for what AFUE is and is not
- Checked
- Checked on every build, most recently on November 11, 2026. On every build, an automated check runs the locked engine that produces these figures and holds its answers against the values this site holds, written from the source it cites, so a checked number answers to its source and not merely to itself. The check covers the cases someone wrote a check for, not every input the tool accepts: it tells you where a number comes from, and it is not a proof of every value. As of the current build that suite holds 35,006 checks, and this page has to clear them too. This is our own deterministic gate, not a third-party audit.
- Tested safeguards
- The status its saved reading files for a rise below the furnace plate's range, for a reading taken with the blower door off, and for an oil-fired furnace, which it refuses, carry their own safeguards: when the code behind them is broken on purpose, the safeguards catch it.
- Source changes
- No source has been added to or removed from this tool since this record began on October 24, 2026.
- Runnable
- A reference engine behind the published numbers on this site. Runnable access is offered on the calculators exposed at the Intry MCP endpoint.
- Final say
- The rating plate and the manufacturer's installation instructions for your model have final say, and a combustion analysis is what confirms the furnace is safe. A rise inside the plate band is not a clean bill of health.
Frequently Asked Questions
Is the Intry Furnace Temperature Rise Calculator accurate?
It computes from the sources listed in the source receipt on its tool page, and our automated checks hold its answers against values written from those sources for the cases the checks cover, not for every input you can enter. The rating plate and the manufacturer's installation instructions for your model have final say, and a combustion analysis is what confirms the furnace is safe. A rise inside the plate band is not a clean bill of health. Every figure an Intry calculator computes comes from a locked source module, not hand-typed. 35,006 automated checks, one suite for the whole site rather than a per-tool count, re-derive those figures and re-check the manufacturer method this tool applies before each deploy. The standard it judges your reading against is the temperature rise range printed on the unit's own rating plate, which you supply, so no check of ours can confirm that what you entered is what is printed on your equipment. This is our own deterministic gate, not a third-party audit. The per-tool receipt is public at https://www.intrysys.com/verified.