Is the Intry Tap Conductor Calculator accurate and NEC compliant?

The provenance receipt for the Intry Tap Conductor Calculator: the exact authority its values derive from, the edition they are keyed to, who has final say, and what our automated checks hold them against, rebuilt from their cited source.

Short answer: It computes from the NEC sections named below (NEC 2023), and our automated checks hold its answers against values written from those sources for the cases the checks cover, not for every input you can enter. Whether an installation is NEC compliant is decided by the inspector, not by a calculator. Your AHJ has final say. This sizes the conductor; the conditions each tap rule places on the installation still have to be met on the job. Every figure an Intry calculator computes comes from a locked source module, not hand-typed. 31154 automated checks, one suite for the whole site rather than a per-tool count, re-derive the numbers before each deploy from the tables this site transcribed from the cited NEC 240.21(B) tap rule and Table 310.16. This is our own deterministic gate, not a third-party audit. The per-tool receipt is public at https://www.intrysys.com/verified.

The receipt

Calculated from
NEC 2023 240.21(B)(1) through (B)(5), feeder taps · NEC 2023 240.21(B) preamble, no next-size rounding on a tap · NEC Table 310.16, allowable ampacities (NEC 2023). Reused verbatim from the locked engine, never re-written for this page. The documents it rests on are listed in the source receipt on the tool page.
Edition
NEC 2023
Checked
Before any release, an automated check runs the locked engine that produces these figures and holds its answers against values written from the source it cites, so a checked number answers to its source and not merely to itself. The check covers the cases someone wrote a check for, not every input the tool accepts: it tells you where a number comes from, and it is not a proof of every value. As of the current build that suite holds 31154 checks, and this page has to clear them too. This is our own deterministic gate, not a third-party audit.
Runnable
A reference engine behind the published numbers on this site. Runnable access is offered on the calculators exposed at the Intry MCP endpoint.
Final say
Your AHJ has final say. This sizes the conductor; the conditions each tap rule places on the installation still have to be met on the job.

Frequently Asked Questions

Is the Intry Tap Conductor Calculator accurate and NEC compliant?

It computes from the NEC sections named below (NEC 2023), and our automated checks hold its answers against values written from those sources for the cases the checks cover, not for every input you can enter. Whether an installation is NEC compliant is decided by the inspector, not by a calculator. Your AHJ has final say. This sizes the conductor; the conditions each tap rule places on the installation still have to be met on the job. Every figure an Intry calculator computes comes from a locked source module, not hand-typed. 31154 automated checks, one suite for the whole site rather than a per-tool count, re-derive the numbers before each deploy from the tables this site transcribed from the cited NEC 240.21(B) tap rule and Table 310.16. This is our own deterministic gate, not a third-party audit. The per-tool receipt is public at https://www.intrysys.com/verified.


Use it