Carrier Tonnage From Model Number
Where Carrier puts the capacity code, what each code means, and the readings that look like capacity but are not. Read out of 7 documents Carrier publishes itself, named further down with the date each was fetched.
Starting the decoder. The capacity tables below this box are already loaded, so you can read your code off them now.
Nominal capacity from a model number is a nameplate convention, not a measurement. Actual delivered capacity depends on the matched indoor unit, line set, airflow and conditions. Confirm against the data plate's BTU/h rating and the AHRI certificate for the matched system.
Carrier Capacity Codes and Tonnage
24 and 25 families (current lettered series)
Capacity sits at positions 7-8, the two digits after the series letters and the SEER digit, per Carrier's own nomenclature table. Example: 24ABC636A0030.
Read from the model-number position a manufacturer nomenclature document defines. That document defines where the capacity code sits; the capacity figure itself is this tool's reading of it.
| Code | Nominal BTU/h | Tons | Code / 12 |
|---|---|---|---|
| 18 | 18,000 | 1.5 | same answer |
| 24 | 24,000 | 2 | same answer |
| 30 | 30,000 | 2.5 | same answer |
| 36 | 36,000 | 3 | same answer |
| 48 | 48,000 | 4 | same answer |
| 60 | 60,000 | 5 | same answer |
Table transcribed from 2016 Nomenclatures: Air Conditioners, Heat Pumps, Fan Coils, Evaporator Coils, 90% Gas Furnaces and 80% Gas Furnaces (2016cac_nomen, 2016), published by www.shareddocs.com, fetched 2026-07-24.
24 and 25, 2008 layout (Major Series A or R)
Capacity sits at positions 7-8, after the Major Series letter at position 5 (A = Puron, R = R22) and the SEER digit at position 6, per Carrier's own 2008 service manual nomenclature. Example: 24ABR636A003.
Read from the model-number position a manufacturer nomenclature document defines. That document defines where the capacity code sits; the capacity figure itself is this tool's reading of it.
| Code | Nominal BTU/h | Tons | Code / 12 |
|---|---|---|---|
| 18 | 18,000 | 1.5 | same answer |
| 24 | 24,000 | 2 | same answer |
| 30 | 30,000 | 2.5 | same answer |
| 36 | 36,000 | 3 | same answer |
| 42 | 42,000 | 3.5 | same answer |
| 48 | 48,000 | 4 | same answer |
| 60 | 60,000 | 5 | same answer |
Table transcribed from Residential Air Conditioners and Heat Pumps Using R-22 and Puron Refrigerant: Application Guideline and Service Manual (Catalog No. 24-25-2SM, Edition Date 04/08), published by www.shareddocs.com, fetched 2026-09-17.
27SCA5 and 26SCA5 (R-454B)
Capacity sits at positions 7-8, after the refrigerant and outdoor type at positions 1-2 and the SEER2 digit at position 6, per Carrier's own 27SCA5 and 26SCA5 nomenclature. Example: 27SCA536A003.
Transcribed from the manufacturer's own capacity legend for the Carrier product-category scheme. The capacity, not just the position, is printed in a document this tool holds.
| Code | Nominal BTU/h | Tons | Code / 12 |
|---|---|---|---|
| 18 | 18,000 | 1.5 | same answer |
| 24 | 24,000 | 2 | same answer |
| 30 | 30,000 | 2.5 | same answer |
| 36 | 36,000 | 3 | same answer |
| 42 | 42,000 | 3.5 | same answer |
| 48 | 48,000 | 4 | same answer |
| 60 | 60,000 | 5 | same answer |
Table transcribed from 27SCA5 Comfort™ Series Single-Stage Heat Pump with Puron Advance™ Refrigerant Product Data (27SCA5-02PD, Edition Date: 05/25), published by www.shareddocs.com, fetched 2026-10-01.
Worked example: Carrier 24ABC636A0030
Capacity code 36 at characters 7-8 of 24ABC636A0030: 36,000 BTU/h, which is 3 tons at 12,000 BTU/h per ton. 2 digit BTU/1000 capacity code; the digit before it is position 6, which Carrier's 2016 Nomenclatures heads SEER.
- Product family: AC condenser. Leading digits 24 (24 = AC condenser, 25 = heat pump, 58/59 = gas furnace).
- Efficiency: 16 SEER. Carrier's 2016 Nomenclatures prints "6 = 16.0" under "SEER" for its Air Conditioners (position 6): the series' class, not this unit's rating.
- Refrigerant: R-410A (Puron). Position 5 reads "C". Carrier's 2016 Nomenclatures prints Major Series "A,B,C = Puron® refrigerant", and Catalog No 24ABC6-8PD prints the refrigerant as "Puron® (R−410A)".
Carrier has 3 documented layouts: 24 and 25 families (current lettered series) reads capacity at positions 7-8; 24 and 25, 2008 layout (Major Series A or R) reads capacity at positions 7-8; 27SCA5 and 26SCA5 (R-454B) reads capacity at positions 7-8. They agree on where the capacity sits and differ in what the surrounding positions mean, so the size decodes the same way on both while the refrigerant and efficiency digits do not.
What is specific to Carrier
Carrier equipment in the decoder
The decoder reads or identifies these Carrier lines; each one says what it rests on. Open an example to see the decoder's full answer for it.
| Line | Example model | What the decoder reads | Document |
|---|---|---|---|
| Carrier N coil (CNPVP, CNPVT, CNPVU, CNRVU) | CNPVP1814ACA | An indoor coil: 1.5 tons (18,000 BTU/h) | PDSCNPV-08 |
| Carrier 27SCA5 heat pump | 27SCA524A003 | 2 tons (24,000 BTU/h) | 27SCA5-02PD |
| Carrier 26SCA5 air conditioner | 26SCA524W003 | 2 tons (24,000 BTU/h) | 26SCA5-02PD |
| Carrier 38TDA two-speed air conditioner | 38TDA036301 | 3 tons (36,000 BTU/h) | Form 38TDA-4PD |
| Carrier 38 Puron split system (Form 38-12SM) | 38TXA018301 | 1.5 tons (18,000 BTU/h) | Form 38-12SM |
| Carrier CVAMA V coil | CVAMA3617XMA | An indoor coil: 3 tons (36,000 BTU/h) | CVAMA-01PD |
| Carrier 30RB AquaSnap air-cooled chiller | 30RB060 | An air-cooled chiller: large commercial equipment, outside this tool's range, so no tonnage is read | Form 30RB-27PD Rev. I |
| Carrier 30XA AquaForce air-cooled liquid chiller | 30XA080 | An air-cooled liquid chiller: large commercial equipment, outside this tool's range, so no tonnage is read | Form 30XA-22PD Rev. F |
| Carrier 37MUHA outdoor variable speed heat pump | 37MUHAQ36AA3 | The outdoor unit of a split system heat pump: 3 tons (36,000 BTU/h) | 37MUHA-01PD |
- Carrier small packaged unit (50VG, 48VG, 50VR, 48VR, 50VL, 48VL, 50VT, 48VT, 50ZP, 50ZH): packaged or light commercial; its capacity is read from the maker's own printed legend or table, for the codes it prints.
- Carrier Aquazone water-source heat pump (50PCH, 50PCV, 50PSH, 50PSV, 50PTH, 50PTV, 50PSW, 50HQP, 50VQP, 50PEC): packaged or light commercial; its capacity is read from the maker's own printed legend or table, for the codes it prints.
- Carrier Omnizone indoor self-contained unit (50XC, 50BV): packaged or light commercial; identified by its maker's form, and no capacity legend for it is held, so no tonnage is read.
- Carrier packaged rooftop (48 family): packaged or light commercial; its capacity is read from the maker's own printed legend or table, for the codes it prints.
- Carrier packaged rooftop (50 family): packaged or light commercial; matched by its model prefix, with no maker legend held, so no tonnage is read.
CPSC recall notices naming Carrier
Hazard, in the notice's words: “The fan motor on the heat pumps can fail, causing the units to overheat, posing a fire hazard.”
Hazard, in the notice's words: “The capacitors in the fuse boards in the heat pumps can stop working causing the unit to overheat, posing a fire hazard.”
Hazard, in the notice's words: “Heat exchangers in the furnace can crack.”
Whether a particular unit is inside a recall depends on the models and serials the notice lists. The Carrier serial number lookup checks a unit against the notices.
Bryant, same family as Carrier
Bryant is in Carrier's family. These are Bryant's lines; each one says what it rests on.
| Line | Example model | What the decoder reads | Document |
|---|---|---|---|
| Bryant 310AAV/310JAV gas furnace | 310AAV066135 | A gas furnace: its size field is heating input, so no cooling tonnage is read | PDS310A-11 |
- Bryant packaged rooftop (580J, 581J, 582L, 559L; 3 to 27.5 tons): packaged or light commercial; its capacity is read from the maker's own printed legend or table, for the codes it prints.
The Carrier documents behind this page
Published by carrier.com.pr. Fetched 2026-07-24. Covers the position only: its MODEL NUMBER NOMENCLATURE table numbers positions 1-13 over Carrier's own worked example and prints position 6 as SEER and positions 7-8 as Cooling Capacity. It prints no code-to-tonnage table, so no tonnage on this page comes from it.
Published by www.shareddocs.com. Fetched 2026-07-24. Covers the code-to-tonnage table itself, for both residential families: the Air Conditioners row (Product Series 24) and the Heat Pumps row (Product Series 25) each print positions 7-8 as Cooling Capacity over the same six-code capacity column, transcribed cell by cell into this generation's capacity receipt. It also independently confirms the position claim above.
Published by www.shareddocs.com. Fetched 2026-09-17. Covers page 2, "AIR CONDITIONER AND HEAT PUMP MODEL NUMBER NOMENCLATURE": positions 1-2 Series (24 = AC, 25 = HP), 3 Family (A = A/C, H = HP), 4 Tier (B, C, P, N), 5 Major Series (A = Puron, R = R22), 6 SEER (3, 5, 6, 8), 7-8 Cooling Capacity (Tons), 18 to 60 with 42. It is the page a model off the 2016 layout with major series A or R is read on..
Published by www.shareddocs.com. Fetched 2026-10-01. Covers the 27SCA5 Model Number Nomenclature on p2: positions 1-2 27 = Puron Advance (R-454B) HP, position 6 5=14.3 SEER2, positions 7-8 Nominal Cooling Capacity 18 to 60, for the 27SCA5 series only.
Published by www.shareddocs.com. Fetched 2026-10-01. Covers the 26SCA5 Model Number Nomenclature on p2: positions 1-2 26 = Puron Advance (R-454B) AC and the same capacity column as 27SCA5, for the 26SCA5 series only.
Published by www.shareddocs.com. Fetched 2026-10-01. Covers the 38TDA model number nomenclature on p2: Nominal Capacity 036, 048 and 060 printed in Btuh, and the physical data's refrigerant on p3 (R-22).
Published by www.shareddocs.com. Fetched 2026-09-17. Covers Fig. 9 Model Number Nomenclature on p13: nine 38 series (38TXA, 38TZA, 38TSA, 38EZA, 38EYA, 38YXA, 38YZA, 38TDB, 38YDB) with their printed type words, and Nominal Capacity 018 to 060 in Btuh; Puron is printed as R-410A on p2.
Frequently asked questions
How do I find the tonnage of a Carrier unit from the model number?
Read the capacity code: on Carrier it sits at positions 7-8, the two digits after the series letters and the SEER digit, per Carrier's own nomenclature table. On 24ABC636A0030 that code is 36, which is 36,000 BTU/h, or 3 tons, because one ton of cooling is 12,000 BTU/h. Use the OUTDOOR unit's model number for system cooling capacity; the indoor air handler or coil carries its own number. This position comes from Carrier's own Catalog No 24ABC6-8PD, not from a third-party chart.
Does dividing the Carrier capacity code by 12 always work?
On the codes in Carrier's printed table, yes: each one is the nominal BTU/h divided by 1,000, so dividing by 12 gives the tonnage. That is not true of every brand. Trane, Lennox, Goodman and Amana each print codes where dividing by 12 is wrong, so do not carry the shortcut across brands.
Where is the model number on a Carrier unit?
On the rating plate on the side of the outdoor condenser, near the refrigerant line connections, labeled MODEL NO. It is labeled M/N, MODEL or MODEL NO., usually printed directly above or beside the serial number. The model number describes what the unit is, including its capacity. The serial number describes when it was built and carries no capacity information at all.
Which Carrier document is this based on?
Product Data 24ABC6 Comfort 16 Air Conditioner with Puron Refrigerant, 1-1/2 to 5 Nominal Tons (Catalog No 24ABC6-8PD, Edition Date 05/19), published by carrier.com.pr and fetched 2026-07-24, which covers the position only: its MODEL NUMBER NOMENCLATURE table numbers positions 1-13 over Carrier's own worked example and prints position 6 as SEER and positions 7-8 as Cooling Capacity. It prints no code-to-tonnage table, so no tonnage on this page comes from it. 2016 Nomenclatures: Air Conditioners, Heat Pumps, Fan Coils, Evaporator Coils, 90% Gas Furnaces and 80% Gas Furnaces (2016cac_nomen, 2016), published by www.shareddocs.com and fetched 2026-07-24, which covers the code-to-tonnage table itself, for both residential families: the Air Conditioners row (Product Series 24) and the Heat Pumps row (Product Series 25) each print positions 7-8 as Cooling Capacity over the same six-code capacity column, transcribed cell by cell into this generation's capacity receipt. It also independently confirms the position claim above. Residential Air Conditioners and Heat Pumps Using R-22 and Puron Refrigerant: Application Guideline and Service Manual (Catalog No. 24-25-2SM, Edition Date 04/08), published by www.shareddocs.com and fetched 2026-09-17, which covers page 2, "AIR CONDITIONER AND HEAT PUMP MODEL NUMBER NOMENCLATURE": positions 1-2 Series (24 = AC, 25 = HP), 3 Family (A = A/C, H = HP), 4 Tier (B, C, P, N), 5 Major Series (A = Puron, R = R22), 6 SEER (3, 5, 6, 8), 7-8 Cooling Capacity (Tons), 18 to 60 with 42. It is the page a model off the 2016 layout with major series A or R is read on.. 27SCA5 Comfort™ Series Single-Stage Heat Pump with Puron Advance™ Refrigerant Product Data (27SCA5-02PD, Edition Date: 05/25), published by www.shareddocs.com and fetched 2026-10-01, which covers the 27SCA5 Model Number Nomenclature on p2: positions 1-2 27 = Puron Advance (R-454B) HP, position 6 5=14.3 SEER2, positions 7-8 Nominal Cooling Capacity 18 to 60, for the 27SCA5 series only. 26SCA5 Comfort™ Series Single-Stage Air Conditioner with Puron Advance™ Refrigerant Product Data (26SCA5-02PD, Edition Date: 06/25), published by www.shareddocs.com and fetched 2026-10-01, which covers the 26SCA5 Model Number Nomenclature on p2: positions 1-2 26 = Puron Advance (R-454B) AC and the same capacity column as 27SCA5, for the 26SCA5 series only. SYNERGY 2000 38 TDA (60 Hz) Two-Speed Electric Air Conditioner Sizes 036, 048, and 060 (Form 38TDA-4PD, 2-99), published by www.shareddocs.com and fetched 2026-10-01, which covers the 38TDA model number nomenclature on p2: Nominal Capacity 036, 048 and 060 printed in Btuh, and the physical data's refrigerant on p3 (R-22). Air Conditioners and Heat Pumps Using Puron® Refrigerant Application Guideline and Service Manual (Form 38-12SM, 4-05), published by www.shareddocs.com and fetched 2026-09-17, which covers Fig. 9 Model Number Nomenclature on p13: nine 38 series (38TXA, 38TZA, 38TSA, 38EZA, 38EYA, 38YXA, 38YZA, 38TDB, 38YDB) with their printed type words, and Nominal Capacity 018 to 060 in Btuh; Puron is printed as R-410A on p2. Every capacity value in the capacity tables above traces to one of those documents, and each is named with the date it was fetched so you can pull it yourself. The sizes in the equipment table are read from the document named in its Document column, listed on this page's source receipt.
Is the decoded tonnage the size I should install?
No. Nominal tonnage is what the unit was built to deliver, not what the building needs, and the old unit may have been oversized or sized before insulation and window changes. Treat it as a starting clue and run a load calculation before matching a replacement. Actual delivered capacity also depends on the matched indoor unit, line set, airflow and conditions.
Related tools
Tonnage From Model Number (all brands)
The full decoder: 40+ brands, the universal capacity ladder, and the brands whose own tables override it.
Carrier Serial Number Lookup
The model number gives the size. The serial gives the age and the refrigerant era. Decode Carrier build dates.
BTU / HVAC Load Calculator
Size the actual load by climate zone, insulation and windows, then check it against the decoded nominal tonnage.
MCA / MOCP Breaker & Wire Size
Got the size? Size the circuit next: nameplate MCA and MOCP to wire, breaker and ground per NEC Article 440.
Other brands with their own manufacturer nomenclature document: Trane tonnage by model number, American Standard tonnage by model number, Lennox tonnage by model number, Goodman tonnage by model number, Amana tonnage by model number.
Got a central system's tonnage? Check it against the house's load.
The old unit's nominal size is a clue, not a load calculation. Oversized systems short-cycle and dehumidify poorly. For central equipment that conditions the whole house, run the numbers before you match a replacement. A PTAC, a single package vertical unit, a room air conditioner or one unit of a VRF system conditions a room or a zone, which this load calculator does not size.