HVAC Serial Number Lookup
Mitsubishi Electric Serial Number Lookup
Mitsubishi Electric has its own serial number formats; the rows below say which are read from the manufacturer's own document. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.
Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.
7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. Some of the formats on this page are read from the manufacturer's own document; the others rest on secondary references, and each row below says which. A date stamped or printed on the data plate always outranks a serial decode.
Mitsubishi Electric Serial Number Formats
| Format | Era | Example | Confidence |
|---|---|---|---|
| 9 characters; first digit = last digit of the year (decade not encoded), second character = month (1-9 = Jan-Sep, X = Oct, Y = Nov, Z = Dec)Cross-checked across 2 secondary references, not a manufacturer document. | ~2000s to present | 89D00488D = September of a year ending in 8 (2018 for an R-410A unit) | medium |
| 8 characters ending in T; first digit = last digit of the year. No month is decoded from this styleCross-checked across 2 secondary references, not a manufacturer document. | older units | 8001637T = a year ending in 8, month unknown | medium |
| 8 characters; first digit = production season (April to March; decade not encoded), second character = month (1-9 = Jan-Sep, X = Oct, Y = Nov, Z = Dec), third = W (the Wakayama works), G (Georgia, City Multi outdoor units; no reading before the season that began April 2014) or P (printed in Mitsubishi's City Multi outdoor unit handbook without a meaning), then a 5-digit sequenceManufacturer documents, held as retained copies. No secondary reference is relied on. The manufacturer's document "Service Parts List for Mitsubishi Electric Packaged Air-Conditioners, PEFY-P72NMHSU-E, PEFY-P96NMHSU-E", which prints the legend for the "Serial No. of Air Conditioning & Refrigeration Systems Works" in a service parts list. | era not stated in Mitsubishi's parts list | 27W02290 = July of a season-2 year (July 2012 on Mitsubishi's own example) | medium |
Worked Example: Mitsubishi Electric 89D00488D
Expected decode: September of a year ending in 8 (2018 for an R-410A unit). Character by character:
8 = last digit of the year (decade is not encoded): 2018 shown
9 = September (1-9 = Jan-Sep, X/Y/Z = Oct/Nov/Dec)
The decade is not in the serial; candidates shown newest first. The refrigerant on the nameplate narrows it (R-410A from roughly 2008 on, R-454B from the A2L changeover EPA's 2025 rule brought in) but cannot choose between two readings that share a refrigerant; a manufacture date printed on the data plate, where there is one, settles it. Mitsubishi's own serial legends differ by product: some print a production season that starts in April, so a January to March unit carries the previous season's digit, and others print the calendar year. No Mitsubishi document this tool holds states which applies to this nine-character layout, so the calendar reading is shown.
8 = last digit of the year (decade is not encoded): 2008 shown
9 = September (1-9 = Jan-Sep, X/Y/Z = Oct/Nov/Dec)
8 = last digit of the year (decade is not encoded): 1998 shown
9 = September (1-9 = Jan-Sep, X/Y/Z = Oct/Nov/Dec)
More than one reading passes the validity checks for this serial, so all of them are shown, ranked, instead of a single guess.
Mitsubishi Electric serials from public records, dated
Each serial in the record tables below is listed under Mitsubishi Electric in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026.
The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.
Norcross, Georgia: 2 serials; the decoder reads 0 of 2 as the year listed and shows it among other years for 2
The record: Document Center file 8177.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| 63U02976B | Mini Split Condenser | 2016 | March 2026 or March 2016 or March 2006 | Same year, one of the years shown |
| 28U28469D | Mini Split Condenser | 2022 | August 2022 or August 2012 or August 2002 | Same year, one of the years shown |
Wayne Township, New Jersey: 1 serial; the decoder reads 0 of 1 as the year listed and does not decode 1
The record: Wayne, Township of LGEA 07282014 FINAL Redacted.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| 20030603T | Not listed per unit | 2003 | No reading | Not decoded |
Reading Mitsubishi Electric model numbers
The Mitsubishi Electric lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the tonnage decoder.
| Line | Example model | What the tonnage decoder reads | Document |
|---|---|---|---|
| Mitsubishi Electric Trane P-Series wall-mounted indoor unit | TPKA0A0121KA70A | A wall-mounted ductless indoor unit: 1 ton (12,000 BTU/h) | TR-CM-1595 |
Mitsubishi Electric Refrigerant Timeline
| Manufacture year | Refrigerant the years point to | Notes |
|---|---|---|
| through 2007 | R-22 | Early Mitsubishi mini splits ran R-22. |
| 2008 to 2024 | R-410A | R-410A era for Mitsubishi ductless and multi-zone systems. |
| 2025 and later | R-454B | Mitsubishi Electric Trane HVAC US chose R-454B, unusual among mini-split makers (most picked R-32). |
The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.
Mitsubishi Electric Warranty Terms
Mitsubishi Electric warranty lookup
No page of Mitsubishi Electric's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered.
Enter the serial in the lookup on this page for the build date and the unit's age. No Mitsubishi Electric warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit.
What this tool holds on Mitsubishi Electric's warranty
Mitsubishi Electric warrants parts for five years and the compressor for seven. For systems purchased from April 1, 2015 to April 30, 2019, registering within 90 days of installation in a residential single-family home extends both, further with a Diamond Contractor install; the statement for systems purchased from July 1, 2009 to March 31, 2015 prints no registration term. A later statement (Rev-2.9.2026) is held, but its header limits it to products purchased from October 25, 2025 through February 8, 2026 and its body to products purchased on or after its February 9, 2026 effective date, so this tool does not read a term from it.
The result does not work out a dated term for Mitsubishi Electric: no Mitsubishi Electric certificate is registered for that here. Only the maker's records show whether a unit was registered.
Source: Mitsubishi Electric limited warranty statements (2009 and 2015 editions).
Frequently Asked Questions
How old is my Mitsubishi Electric unit?
Decode the serial number from the data plate. The dominant Mitsubishi Electric format (~2000s to present) is: 9 characters; first digit = last digit of the year (decade not encoded), second character = month (1-9 = Jan-Sep, X = Oct, Y = Nov, Z = Dec). Example: 89D00488D decodes to September of a year ending in 8 (2018 for an R-410A unit). Subtract the decoded year from the current year for the age.
Why can a Mitsubishi Electric serial number decode to more than one date?
The main Mitsubishi Electric rule carries medium confidence, so treat the result as an estimate to check against the data plate. The decade is not in the serial; candidates shown newest first. The refrigerant on the nameplate narrows it (R-410A from roughly 2008 on, R-454B from the A2L changeover EPA's 2025 rule brought in) but cannot choose between two readings that share a refrigerant; a manufacture date printed on the data plate, where there is one, settles it. Mitsubishi's own serial legends differ by product: some print a production season that starts in April, so a January to March unit carries the previous season's digit, and others print the calendar year. No Mitsubishi document this tool holds states which applies to this nine-character layout, so the calendar reading is shown.
Has the Mitsubishi Electric serial decode been checked against serials somebody else dated?
Mitsubishi Electric 9-character: Read against 2 serials where a public body's own equipment schedule prints a year beside the serial (Norcross, Georgia; the year sits under a column headed Year, which the document does not define), mini split condenser: 1 matched the reading shown first, 1 matched a later reading.
No serial with a date published outside this tool has produced a reading through the Mitsubishi Electric 8-character works serial (W, G or P) format yet. That format is read from a document published by the company that built the unit.
No serial with a date published outside this tool has produced a reading through the Mitsubishi Electric 8-character ending in T format yet. No document from the company that built the unit is held for it, so the rule rests on the secondary references this tool records.
Across the Mitsubishi Electric formats on this page, 1 serial with a date published outside this tool produced no reading at all (Wayne Township, New Jersey). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.
What refrigerant does a Mitsubishi Electric unit use?
By manufacture year: through 2007: R-22; 2008 to 2024: R-410A; 2025 and later: R-454B. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.
How do I look up my Mitsubishi Electric warranty?
No page of Mitsubishi Electric's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered. Enter the serial in the lookup on this page for the build date and the unit's age. No Mitsubishi Electric warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit.
Is my Mitsubishi Electric unit still under warranty?
Mitsubishi Electric warrants parts for five years and the compressor for seven. For systems purchased from April 1, 2015 to April 30, 2019, registering within 90 days of installation in a residential single-family home extends both, further with a Diamond Contractor install; the statement for systems purchased from July 1, 2009 to March 31, 2015 prints no registration term. A later statement (Rev-2.9.2026) is held, but its header limits it to products purchased from October 25, 2025 through February 8, 2026 and its body to products purchased on or after its February 9, 2026 effective date, so this tool does not read a term from it. The result does not work out a dated term for Mitsubishi Electric: no Mitsubishi Electric certificate is registered for that here. Only the maker's records show whether a unit was registered.
Related Tools
HVAC Serial Number Lookup (All Brands)
The full decoder: 50+ brands across every major manufacturer family, with ambiguous formats shown honestly.
Tonnage From Model Number
The serial tells you the age; the model number tells you the size. Decode BTU capacity and tons from the model.
A2L Refrigerant Charge Limit Calculator
Replacing an old unit with R-454B or R-32 equipment? Check the room-size charge limits per UL 60335-2-40.
Different brand on the data plate?
The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.