HVAC Serial Number Lookup

LG Serial Number Lookup

LG's serial format is read from a document published by the company that built the unit. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.

Quick answer: LG serial numbers (~2007 to present): First digit = last digit of the year (decade not encoded), digits 2-3 = month 01-12; where the first four digits also read as a two-digit year and month, the form LG's Multi V manuals print, that reading is shown as well. Example: 705KWPZ64912 = May of a year ending in 7.

Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.

Every serial format on this page is read from a document published by the company that built the unit, held as a retained copy. The manufacturer's document "Outdoor Unit Drain Pan Heater", which prints this rule for the LG outdoor units it lists, not for indoor, portable or window units. A date stamped or printed on the data plate always outranks a serial decode.


LG Serial Number Formats

FormatEraExampleConfidence
First digit = last digit of the year (decade not encoded), digits 2-3 = month 01-12; where the first four digits also read as a two-digit year and month, the form LG's Multi V manuals print, that reading is shown as wellCross-checked across 2 secondary references, alongside a manufacturer document held. The manufacturer's document "Outdoor Unit Drain Pan Heater", which prints this rule for the LG outdoor units it lists, not for indoor, portable or window units.~2007 to present705KWPZ64912 = May of a year ending in 7medium

Some older or conflicting LG formats are recognized but deliberately not decoded; the decoder explains why when it sees one instead of guessing.


Worked Example: LG 705KWPZ64912

Expected decode: May of a year ending in 7. Character by character:

May 2017

7 = last digit of the year (decade not encoded): 2017 shown

05 = May (digits 2-3)

The one-digit year does not encode the decade. The refrigerant narrows it but cannot choose between two readings that share a refrigerant; the model generation or the production date printed on the tag settles it.

May 2007

7 = last digit of the year (decade not encoded): 2007 shown

05 = May (digits 2-3)

More than one reading passes the validity checks for this serial, so all of them are shown, ranked, instead of a single guess.

LG serials from public records, dated

Each serial in the record tables below is listed under LG in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026.

The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.

Norcross, Georgia: 1 serial; the decoder reads 0 of 1 as the year listed and shows it among other years for 1

The record: Document Center file 8177.

SerialEquipment, as listedYear the record listsThe decoder readsAgainst the year listed
212HAZXA5685Window Unit2022December 2022 or December 2012 or December 2002Same year, one of the years shown

Reading LG model numbers

The LG lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the tonnage decoder.

Each line is identified from the maker document in its Document column. The example is a model in that line's layout, and the reading is what the tonnage decoder returns for it.
LineExample modelWhat the tonnage decoder readsDocument
LG Multi F / Multi F MAX multi-zone systemLMU303HVA unit of an LG Multi F multi-zone system: 2.5 tons (30,000 BTU/h)EM_MultiFODU_3HV_1HV_12_2023
LG Multi F MAX R-32 multi-zone outdoor unitKUMXB301AThe outdoor unit of an LG Multi F MAX multi-zone system: 2.5 tons (30,000 BTU/h)EM_Multi_F-MAX_ODU_R32_06_26
LG R-32 single-zone extended piping wall mountKSSAP241AA unit of an LG single-zone extended piping wall-mount system: 2 tons (24,000 BTU/h)EM_SZ_Extended_Piping_R32_02_26
LG Multi V 5 outdoor unitARUM072BTE5An LG Multi V 5 outdoor unit of a VRF system: identified, no size is readEM_MultiV5_LGRED_OutdoorUnits_11_24
LG Multi V S outdoor unitARUM036GSS5An LG Multi V S outdoor unit of a VRF system: identified, no size is readEM_MultiV_S_LGRED_OutdoorUnits_12_22
LG Multi V heat recovery unitPRHR023AAn LG Multi V heat recovery unit of a VRF system: identified, no size is readEM_MultiV5_LGRED_OutdoorUnits_11_24
LG Multi V outdoor unitARUM072BTE4An LG Multi V outdoor unit of a VRF system: identified, no size is readEM_MultiV5_LGRED_OutdoorUnits_11_24

LG Refrigerant Timeline

Manufacture yearRefrigerant the years point toNotes
through 2024R-410ALG US residential and light-commercial systems ran R-410A through 2024.
2025 and laterR-32LG chose R-32 for US split systems, VRF, and chillers from 2025.

The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.


LG Warranty Terms

LG warranty lookup

No page of LG's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered.

Enter the serial in the lookup on this page for the build date and the unit's age. No LG warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit.

What this tool holds on LG's warranty

This tool holds no LG warranty certificate; check the terms with LG for your model.

The result does not work out a dated term for LG: no LG certificate is registered for that here. Only the maker's records show whether a unit was registered.

Source: no LG warranty document held.


Frequently Asked Questions

How old is my LG unit?

Decode the serial number from the data plate. The dominant LG format (~2007 to present) is: First digit = last digit of the year (decade not encoded), digits 2-3 = month 01-12; where the first four digits also read as a two-digit year and month, the form LG's Multi V manuals print, that reading is shown as well. Example: 705KWPZ64912 decodes to May of a year ending in 7. Subtract the decoded year from the current year for the age.

Why can a LG serial number decode to more than one date?

The one-digit year does not encode the decade. The refrigerant narrows it but cannot choose between two readings that share a refrigerant; the model generation or the production date printed on the tag settles it.

Has the LG serial decode been checked against serials somebody else dated?

LG current: Checked against 7 serials whose date a recall notice published by someone other than us states (CPSC recall notice 17-055), portable (floor) air conditioners, models LP0711WNR/LP0813WNR/LP0814WNR. Every one was consistent with a reading this format produces, but on all 7 it was not the reading shown first. Where this serial admits more than one date, read them as a set. Also read against 1 serial where a public body's own equipment schedule prints a year beside the serial (Norcross, Georgia; the year sits under a column headed Year, which the document does not define), window unit: 1 matched the reading shown first.

What refrigerant does a LG unit use?

By manufacture year: through 2024: R-410A; 2025 and later: R-32. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.

How do I look up my LG warranty?

No page of LG's own for looking up a warranty is linked here, and this page does not read any maker's records, so it cannot show whether a unit was registered. Enter the serial in the lookup on this page for the build date and the unit's age. No LG warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit.

Is my LG unit still under warranty?

This tool holds no LG warranty certificate; check the terms with LG for your model. The result does not work out a dated term for LG: no LG certificate is registered for that here. Only the maker's records show whether a unit was registered.

Why do some LG serial numbers refuse to decode?

This tool holds one source for the legacy LG format, and its position spec is internally inconsistent, so this tool does not decode it. Check the production date printed on the tag.


Related Tools

Different brand on the data plate?

The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.