HVAC Serial Number Lookup
Daikin Serial Number Lookup: AC and Furnace Age
Daikin has no sibling brands here, and the serial number format it uses is shared with Goodman, Amana, Janitrol; the rows below say which formats are read from a document Daikin's manufacturer published. Enter the serial from the data plate below to get the manufacture date with a character-by-character explanation, the unit's age, its refrigerant era, and the warranty picture.
Starting the decoder. The serial formats, the refrigerant timeline and the warranty terms further down this page are already loaded, so you can read yours off them now.
7 of the 41 decode rules rest on a single secondary reference. Where two agree, that is weaker evidence than it looks: secondary references copy one another, and agreement between two is not a manufacturer document being read. Some of the formats on this page are read from the manufacturer's own document; the others rest on secondary references, and each row below says which. A date stamped or printed on the data plate always outranks a serial decode.
Daikin furnace not heating?
Its stop checks come first, then what its light or code means, on furnace codes for Daikin. Type what the furnace shows and it opens there with the brand filled in.
Daikin Serial Number Formats
| Format | Era | Example | Confidence |
|---|---|---|---|
| 10 digits; digits 1-2 = year, digits 3-4 = monthCross-checked across 4 secondary references, alongside a manufacturer document held. The manufacturer's document "Daikin Homeowner Extended Service Agreement", which states the rule "For most products". The manufacturer prints this rule for a narrower product in "Daikin Limited Warranty, Models DMVT, DMVE, DFVE", which states it for "Models: DMVT, DMVE, DFVE"; that document does not cover every unit of this brand. | Goodman since at least 1997; Janitrol 1982-1992; Daikin US unitary 2013+ | 9704011000 = April 1997 | high |
| 14 characters; characters 5-6 = year, characters 7-8 = monthCross-checked across 3 secondary references, not a manufacturer document. | 2000s to present (Japan/Thailand/Mexico-built mini splits) | FBOU0905048200 = May 2009 | medium |
Worked Example: Daikin 1602393269
Expected decode: February 2016 (Daikin unitary). Character by character:
16 = year 2016 (digits 1-2)
02 = February (digits 3-4)
393269 = production sequence
Daikin serials from public records, dated
Each serial in the record tables below is listed under Daikin in a public body's own equipment record, beside a year. “The decoder reads” is what the serial lookup on this page returns for it, worked out when this page was built in 2026. Serials on government surplus listings, a weaker check, follow the records.
The questions below count per format, over every brand using it, and count any matching reading, so their counts can differ.
Winter Park, Florida: 13 serials; the decoder reads 3 of 13 as the year listed and does not decode 10
The records: City operations energy audit 2023-09, Tennis center tower energy audit 2023-09, Ward park energy audit 2023-09, Wellness place energy audit 2023-09, Swoope water plant energy audit 2023-09.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| E012614 | Fan Coil Unit | 2018 | No reading | Not decoded |
| K002135 | Condensing Unit | 2019 | No reading | Not decoded |
| K003037 | Fan Coil Unit | 2019 | No reading | Not decoded |
| K003257 | Condensing Unit | 2019 | No reading | Not decoded |
| K015655 | Condensing Unit | 2019 | No reading | Not decoded |
| K016606 | Fan Coil Unit | 2019 | No reading | Not decoded |
| 2011696701 | Condensing Unit | 2020 | November 2020 | Same year |
| E001245 | Condensing Unit | 2020 | No reading | Not decoded |
| E002848 | Condensing Unit | 2020 | No reading | Not decoded |
| E002449 | Condensing Unit | 2021 | No reading | Not decoded |
| E005068 | Fan Coil Unit - Mini Split | 2021 | No reading | Not decoded |
| 2201205411 | Split System Condensing Unit | 2022 | January 2022 | Same year |
| 2208464114 | Air Handling Unit | 2022 | August 2022 | Same year |
Hawaii State Department of Education: 11 serials; the decoder reads 0 of 11 as the year listed and does not decode 11
The record: IFB D24 109 Solicitation.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| E001792 | Fan Coil Unit | 2011 | No reading | Not decoded |
| E002646 | Fan Coil Unit | 2011 | No reading | Not decoded |
| A000119 | Air-Cooled Condensing Unit | 2014 | No reading | Not decoded |
| A000134 | Air-Cooled Condensing Unit | 2014 | No reading | Not decoded |
| E000429 | Fan Coil Unit - Split System | 2014 | No reading | Not decoded |
| E000846 | Fan Coil Unit - Split System | 2014 | No reading | Not decoded |
| E001240 | Fan Coil Unit - Split System | 2014 | No reading | Not decoded |
| E001256 | Fan Coil Unit - Split System | 2014 | No reading | Not decoded |
| E001764 | Fan Coil Unit - Split System | 2014 | No reading | Not decoded |
| E002549 | Fan Coil Unit - Split System | 2014 | No reading | Not decoded |
| E002559 | Fan Coil Unit - Split System | 2014 | No reading | Not decoded |
Mobile, Alabama: 1 serial; the decoder reads 1 of 1 as the year listed
The record: PC60828394 360 Traffic Engineering FCA DRAFT 10-17-17.
| Serial | Equipment, as listed | Year the record lists | The decoder reads | Against the year listed |
|---|---|---|---|---|
| 1605286473 | Condenser | 2016 | May 2016 | Same year |
Daikin serials on government surplus listings
On these, the year is one a seller entered in the listing's own year field, not a year the manufacturer or a public record states, so it is a weaker check than a public record. “The decoder reads” is what the serial lookup on this page returns for the serial, worked out when this page was built in 2026. The listings are not named here, because a seller's entry is not a citation. 2 serials; the decoder reads 0 of 2 as the year listed.
| Serial | Equipment, as listed | Year a seller entered | The decoder reads | Against the year listed |
|---|---|---|---|---|
| 1609142183 | DM96HS 100 furnace in two-unit lot | 2018 | September 2016 | A different year |
| 1707509180 | CAPF4961C6DB coil in two-unit lot | 2018 | July 2017 | A different year |
Reading Daikin model numbers
The Daikin lines the tonnage decoder reads or identifies, each from the maker document its row names; an example opens on the tonnage decoder.
| Line | Example model | What the tonnage decoder reads | Document |
|---|---|---|---|
| Daikin DX13SA air conditioner | DX13SA0421AA | 3.5 tons (42,000 BTU/h) | SS-DX13SA |
| Daikin DX14SA air conditioner | DX14SA0361AA | 3 tons (36,000 BTU/h) | SS-DX14SA |
| Daikin DZ14SA heat pump | DZ14SA0361AA | 3 tons (36,000 BTU/h) | SS-DZ14SA |
| Daikin DZ16SA heat pump | DZ16SA0361AA | 3 tons (36,000 BTU/h) | SS-DZ16SA |
| Daikin DX18TC air conditioner | DX18TC0481AA | 4 tons (48,000 BTU/h) | SS-DX18TC |
| Daikin DZ18TC heat pump | DZ18TC0481AA | 4 tons (48,000 BTU/h) | SS-DZ18TC |
| Daikin DX20VC air conditioner | DX20VC0481AA | 4 tons (48,000 BTU/h) | SS-DX20VC |
| Daikin DZ20VC heat pump | DZ20VC0481AA | 4 tons (48,000 BTU/h) | SS-DZ20VC |
| Daikin Trailblazer AGZ-E air-cooled scroll chiller | AGZ031E | An air-cooled scroll chiller: large commercial equipment, outside this tool's range, so no tonnage is read | Catalog 624-23 |
| Daikin Trailblazer AGZ-F air-cooled scroll chiller | AGZ030F | An air-cooled scroll chiller: large commercial equipment, outside this tool's range, so no tonnage is read | Catalog 635-4 |
CPSC recall notices naming Daikin
Hazard, in the notice's words: “A power interruption in the heat pump can result in the product providing heat when the power resumes, despite the thermostat being in cooling mode, posing a risk of excessive heat exposure to consumers.”
Hazard, in the notice's words: “The labels found on the serial plate have incorrect electrical information that could result in installers and servicers using undersized wiring or incorrect fuse/circuit breaker parts, posing a fire hazard.”
Hazard, in the notice's words: “The blower motor is not grounded, posing an electrical shock hazard to individuals servicing the units”
Whether a particular unit is inside a recall depends on the models and serials the notice lists. The serial lookup on this page checks a unit against the notices.
Daikin Refrigerant Timeline
| Manufacture year | Refrigerant the years point to | Notes |
|---|---|---|
| through 1995 | R-22 | R-22 was the standard refrigerant for equipment of this age. R-410A did not become an EPA-accepted substitute for HCFC-22 in household and light commercial air conditioning until February 8, 1996, so a unit built before then predates it. Standard refrigerant of the era. EPA ended U.S. production and import of R-22 on January 1, 2020; an existing system can still be serviced with recycled, reclaimed or previously produced R-22. |
| 1996 to 2012 | R-22 or R-410A | Pre-Goodman-era Daikin US products vary, and no Daikin document held here dates the change, so the year does not tell which; check the nameplate or the spec sheet. |
| 2013 to 2023 | R-410A | Goodman-built Daikin unitary (DX prefix) ran R-410A. Mini splits were mostly R-410A through the early 2020s, but Daikin moved US ductless to R-32 ahead of the unitary lines; the model's spec sheet governs. |
| 2024 and later | R-32 | Daikin committed its US residential portfolio to R-32; Goodman-built R-32 lines started production mid-2024. For mini splits, decode refrigerant from the model spec sheet, not the year. |
The refrigerant printed on the nameplate is authoritative. This timeline reads each year range from the EPA dates and maker notes in its Notes column; it tells you what the age points to, not what is in a specific unit.
Daikin Warranty Terms
Daikin warranty lookup
The maker's own page: Daikin's own warranty lookup, at daikincomfort.com. The page is headed "Look up your warranty." This page reads no maker's records and cannot show whether a unit was registered. Open Daikin's own warranty lookup
Enter the serial in the lookup on this page for the build date and the unit's age. No Daikin warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit.
3 U.S. Consumer Product Safety Commission recall notices this tool matches name Daikin equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
What this tool holds on Daikin's warranty
Daikin certificate PWDACHPR3BEO (07/2024; DH4SE, DH5SE, DC3SE, DC4SE and DC5SE) gives all parts up to 5 years unregistered and up to 12 years if registered online within 60 days of installation, for as long as the original registered owner or his or her spouse owns and lives in the home (the certificate excepts units installed in Texas or Florida); where the install date cannot be verified, it is taken as three months after the manufacture date. A registered unit whose compressor fails in the first 6 years can be replaced once, on the certificate's conditions.
The result does not work out a dated term for Daikin: no Daikin certificate is registered for that here. Only the maker's records show whether a unit was registered.
Source: Daikin limited warranty certificate PWDACHPR3BEO (daikinac.com).
Frequently Asked Questions
How old is my Daikin unit?
Decode the serial number from the data plate. The dominant Daikin format (2013 to present, Goodman-built US unitary) is: 10 digits; digits 1-2 = year, digits 3-4 = month. Example: 1602393269 decodes to February 2016 (Daikin unitary). Subtract the decoded year from the current year for the age.
Which brands share the Daikin serial number format?
Daikin shares its serial number FORMAT with Goodman, Amana, and Janitrol, so one decode rule reads the date on all of them. That is a format match and nothing more. Refrigerant era and warranty terms are per brand, and this page states Daikin's own.
Has the Daikin serial decode been checked against serials somebody else dated?
Goodman family 10-digit (YYMM): Checked against 10 serials whose date a recall notice published by someone other than us states (CPSC recall notice 08-602, CPSC recall notice 17-103, CPSC recall notice 18-113, CPSC recall notice 22-021), 4 of them air handlers, models AWUF and ACNF, across 4 equipment types. The date this tool reads first was consistent with the published window on all 10. Also read against 56 serials where a public body's own equipment schedule prints a year beside the serial (Norcross, Georgia; Winter Park, Florida; Mobile, Alabama; the year sits under a column headed Year on 53, and under a column headed Year Manuf on 3, 53 of which the document does not define), 24 of them condensing unit, across 11 equipment types: 54 matched the reading shown first, 2 did not match any reading (the published year ran later than this tool's reading on all 2); and 2 serials where a seller entered a year in the listing's own year field on a government surplus listing for the serial (government surplus auction listings), 1 of them CAPF4961C6DB coil in two-unit lot, across 2 equipment types: 2 did not match any reading (the published year ran later than this tool's reading on all 2); a seller's year is shown here for the record and is not counted toward this format's check.
No serial with a date published outside this tool has produced a reading through the Daikin mini split 14-character format yet. No document from the company that built the unit is held for it, so the rule rests on the secondary references this tool records.
Across the Daikin formats on this page, 26 serials with a date published outside this tool produced no reading at all (Winter Park, Florida; Norcross, Georgia; Hawaii State Department of Education). A serial this tool reads nothing from is neither an agreement nor a disagreement, so it is counted in neither.
Where someone outside this tool wrote down a different year for a unit, that year is shown here rather than dropped. It is that publisher's record for the unit, and a schedule or a listing can carry a replacement, system or lot year rather than the build year. The MFG DATE on the unit's data plate is the build date.
What refrigerant does a Daikin unit use?
By manufacture year: through 1995: R-22; 1996 to 2012: R-22 or R-410A; 2013 to 2023: R-410A; 2024 and later: R-32. The refrigerant printed on the nameplate is authoritative; the year-based mapping tells you what the age points to, not what is in a specific unit.
How do I look up my Daikin warranty?
The maker's own page: Daikin's own warranty lookup, at daikincomfort.com. The page is headed "Look up your warranty." This page reads no maker's records and cannot show whether a unit was registered. Enter the serial in the lookup on this page for the build date and the unit's age. No Daikin warranty certificate is registered here for a dated term, so the result dates no term, says so, and names what would answer it; a Service Brief carries what is known to whoever works on the unit. 3 U.S. Consumer Product Safety Commission recall notices this tool matches name Daikin equipment. Where the serial and model entered meet, or may meet, a notice's printed conditions, the result shows that notice first, with CPSC's own hazard and remedy, and compares each condition; where a notice lists models and none was entered, it asks for the model, unless something else entered or read from the serial rules the unit out of that notice. It never says a unit is or is not recalled, and it says nothing when nothing entered meets or may meet one.
Is my Daikin unit still under warranty?
Daikin certificate PWDACHPR3BEO (07/2024; DH4SE, DH5SE, DC3SE, DC4SE and DC5SE) gives all parts up to 5 years unregistered and up to 12 years if registered online within 60 days of installation, for as long as the original registered owner or his or her spouse owns and lives in the home (the certificate excepts units installed in Texas or Florida); where the install date cannot be verified, it is taken as three months after the manufacture date. A registered unit whose compressor fails in the first 6 years can be replaced once, on the certificate's conditions. The result does not work out a dated term for Daikin: no Daikin certificate is registered for that here. Only the maker's records show whether a unit was registered.
Why do some Daikin serial numbers refuse to decode?
A Daikin serial is declined in two cases. It matches none of the 2 Daikin formats this tool documents, or it has the shape that format expects and the values it reads are impossible: a week outside 1 to 53, a month outside 1 to 12, or a year outside 1955 to 2026. Either way the tool states no date rather than guessing one, and says which of the two happened. Secondary references report that some Daikin mini splits and applied units carry no date in the serial and print it in a separate MFG DATE box on the data plate. Where the plate has that box, read the date there.
How old is my Daikin furnace?
Daikin's own limited warranty for the gas furnace models it lists prints "The first four digits of the serial number (YYMM) on the unit indicate the manufacture date."; it is a current certificate, lists its models rather than the word furnace, and the tool reads an older unit's serial by the same rule. Enter the furnace's serial above: the result gives the date and age and says which document covers it, and that it covers furnaces by its scope.
Related Tools
HVAC Serial Number Lookup (All Brands)
The full decoder: 50+ brands across every major manufacturer family, with ambiguous formats shown honestly.
Tonnage From Model Number
The serial tells you the age; the model number tells you the size. Decode BTU capacity and tons from the model.
A2L Refrigerant Charge Limit Calculator
Replacing an old unit with R-454B or R-32 equipment? Check the room-size charge limits per UL 60335-2-40.
Different brand on the data plate?
The full lookup covers 50+ brands across every major manufacturer family, with the same honest handling of ambiguous and undocumented formats.