HVAC / runnable MCP tool
Run the Superheat & Subcooling Calculator in your AI assistant
Through the free Intry MCP server, Claude, ChatGPT, or Cursor runs this exact calculator and hands back a verdict and the cited source, not a guess. Tool name: superheat_subcooling.
What you get back: superheat/subcooling °F (null on a refused reading), each axis's status (over this tool, not-graded or not-reported: the graded words normal, high and low need the equipment, mode and outdoor ambient the web calculator asks for) and its grade phrase (in band, above band, below band, measured), a diagnosis and charging action adjudicated against the charging-method gate, and a verdict with a confidence level and a basis (never a confident call on off-chart pressures or near-zero superheat, and never a confirmed charge conclusion while the outdoor ambient is unstated).
How it computes the answer
Superheat = suction line temp minus saturation temp at suction pressure; subcooling = saturation temp at liquid pressure minus liquid line temp, by PT interpolation. Each axis carries its status and grade phrase, and with the equipment unstated over this tool the charge is not concluded from a reading.
What it cites
Your assistant calls the same engine the interactive calculator calls, with the inputs listed under Inputs. It takes no equipment, operating mode, outdoor temperature or model number: it does not conclude the charge, and it carries no heating-mode charging rule (each heat pump maker prints its own, and a nameplate subcooling figure is a cooling figure in every book we hold). The interactive calculator takes them and makes that call. These are the interactive calculator's sources, including the ones for inputs only it takes.
- CEC-400-2025-010-AP, Reference Appendix RA3 Table RA3.2-1 (Installer Testing at Final)
- The pass and fail bands, and the conditions they hold under. Variable metering devices are judged on subcooling to plus or minus 3 degrees F of the manufacturer-specified target; fixed orifices on superheat to plus or minus 5 degrees F of the target for the conditions; the metering device itself against the manufacturer's specification or 4 to 25 degrees F. The same table states the envelope those tolerances hold inside, and the engine checks it before applying any of them: outdoor dry-bulb 55 to 115 degrees F on a fixed orifice and 55 to 120 on a variable metering device, with return-air dry-bulb at or above 70. The Installer row is the one shipped, never the looser ECC and HERS Rater row beside it.
- CEC-400-2025-010-AP, Reference Appendix RA3 Table RA3.2-2 (target superheat)
- The target superheat grid for fixed-orifice charging, indexed by indoor wet-bulb and outdoor dry-bulb. Cells are copied from the appendix by software rather than by hand, and a sample was compared against a manufacturer grid from a different publisher as an outside check. The comparison is disclosed rather than claimed as proof: two publishers printing the same targets can inherit one lineage.
- California Energy Commission, 2025 Reference Appendices (CEC-400-2025-010-AP), Table RA3.2-1, page RA3-19 (the TXV superheat default and the subcooling tolerance)
- The band a TXV system's superheat is graded against when the equipment maker publishes none: "Superheat meets the Manufacturer's specifications or 4°F ≤ Superheat ≤ 25°F", for residential ducted split systems with a TXV or other variable metering device, installer testing: outdoor air dry bulb 55°F to 120°F, return air dry bulb at least 70°F. Subcooling is graded only against the maker's own target: "Subcooling tolerance ±3°F of the manufacturer-specified target". A fixed orifice's superheat is graded only against the Table RA3.2-2 target, "Superheat tolerance ±5°F of the specified target"; the ±3°F subcooling tolerance is the TXV row's and is never applied to a fixed orifice.
- Lennox 13ACC Installation Instructions (form 504726), page 14, Table 6 (a fixed-orifice subcooling target with the maker's own tolerance)
- A fixed orifice's subcooling is graded only when the technician enters the maker's target AND the tolerance the maker prints beside it. Lennox prints both for its 13ACC fixed-orifice systems: "Liquid Subcooling [± 1°F (.6°C)]", for Lennox 13ACC fixed-orifice systems (HCFC-22), outdoor temperature 65°F and above; the target is the Table 6 cell for the unit's model size and the outdoor temperature, and "Compare the subcooling value with those in table 6. If subcooling is greater than shown, recover some refrigerant. If subcooling is less than shown, add some refrigerant." With no target, or a target with no tolerance, subcooling is shown as measured and not graded.
- Sporlan (Parker) Bulletin 10-9, March 2011, page 14, Table 7 (TXV superheat settings, shown for reference)
- Printed beside a TXV superheat as reference, never as a grade: "Air Conditioning & Heat Pump ... Evaporator Temperature °F 50° to 40° ... Suggested Superheat Setting °F 8° to 12°", with the commercial (6 to 8) and low temperature (4 to 6) rows, and Sporlan's own scope: "These settings are only estimates for typical system designs and should only be used if setting guidelines are unavailable from the system manufacturer".
- CEC-400-2022-010-AP, Joint Appendix JA6.1.6.3 (the airflow precondition; 2022 edition; JA6.1 is RESERVED in the 2025 edition)
- Why this tool checks airflow before it grades a charge, and why it will refuse to grade one. Items 1 to 3 each require that the minimum airflow requirement from item 4 is satisfied before their charge criteria are valid, so a superheat or subcooling reading taken on restricted airflow is not a charge measurement. The direction depends on the metering device: on a fixed orifice a starved evaporator drives superheat DOWN and widens the temperature split, which reads like an overcharge, while on a TXV the valve holds superheat and the fault shows in suction pressure and subcooling. That is the confound the whole air-side check exists to separate.
- Carrier PH5SAN5, Carrier SM10-R454B-03, Carrier 25SCA5, Goodman IOG-4048C, ICP 428 01 5106 00, Trane 88-M5MHWUN-1A-EN, Rheem RD16AY, and Bosch service literature
- Which charging method a given machine actually permits, and when the manufacturer says not to check the charge at all. Carrier PH5SAN5 (R-454B installation instructions) states the outdoor window it publishes for checking charge and states the airflow precondition directly; Trane and Bosch reach the same place in their own words. Carrier SM10-R454B-03 supplies the sentence defining what a dashed cell on a superheat grid means, which is an instruction not to charge on that reading. Goodman IOG-4048C and the ICP grid (428 01 5106 00) supply the dashed regions themselves. Trane 88-M5MHWUN-1A-EN is the ductless installer guide behind the mini-split fork: it publishes no superheat or subcooling procedure at all, which is why this tool declines to issue a reading-based charge verdict on ductless equipment, and we state that as evidence about THAT guide rather than about every ductless machine. Rheem RD16AY supplies the evaporator-icing instruction the engine will not charge through. Where these documents route the technician to a weigh-in or to the unit’s own charging procedure, this tool routes there too instead of grading a reading the manufacturer does not charge from.
- The per-machine charge-target corpus (registered manufacturer books, cited by form number)
- Where a specific machine's target subcooling is written, quoted from that manufacturer's own book with its form number. 15 documents across 7 brand families are registered and content-pinned: Carrier (SM10-R454B); Goodman (IOD-4064A, IOG-4048C, IOG-4064A); York (5391577-UIM-B-0718, 6411591-UIM-B-0824, 6694740-UIM-B-1025); Lennox (100108); Nortek (708921E, 7094080); Rheem (92-104921-25-04, 92-110354-01-01); Trane (11-AC22D1-1, 18-AC94D1-4-EN, 4TWX6060E-SF-1A). The tool publishes NO target subcooling value of its own from any of them. What it publishes is WHERE the figure lives on that machine, what that manufacturer calls it, the sentence it is read from, word for word, and which model series that sentence covers - so a claim read out of one book stops at the machines that book's own cover names. Where a book's current revision cannot be established, or where its own pages disagree, the value stays withheld and the reason is printed instead.
- The heat pump's heating-mode check (each maker's own heat pump book, cited by form number and page)
- In heating, the heat pump check names what the maker of the unit you name prints about charging in heating: a heating procedure and the outdoor window it is printed for, a temperature below which that maker says not to charge, or no heating procedure and the maker's own weigh-in rule. Each sentence is quoted from that maker's book with its page, and a book is applied only to the units and refrigerant its own pages cover; a unit outside them is told the book does not cover it. The books: Carrier, Bryant, Payne: PH5SAN5-01SI; ICP (Heil, Tempstar, Comfortmaker, Arcoaire, Day & Night, KeepRite): ICP 428 01 5106 00; Lennox: Lennox 100195 and Lennox 508700-01; Allied (Armstrong Air, AirEase, Ducane, Concord): Allied 508529-02 and Allied 508530-02; Goodman, Amana, Daikin: Goodman IOG-4064A (November 2024); Nortek (Frigidaire, Gibson, Maytag, Intertherm, Broan): Nortek form 708921E and Nortek form 7094080; Trane, American Standard: Trane 4TWX6060E-SF-1A; Rheem, Ruud: Rheem 92-104921-51-03; York, Luxaire, Coleman: York 6694740-UIM-B-1025. No heating-mode charge check is given, and the check says so, for: Ductless mini-splits and Bard wall-mount packaged units. The check computes no refrigerant quantity and publishes no heating target of its own. Where the book held is superseded or its current revision is not confirmed, its method sentence is quoted with the edition named and no per-length figure from it is published.
- York ST-022-12, Figures 1 and 2 (example charging charts)
- The dose and the wait in the protocol loop: add or remove charge in one-ounce increments and let the system stabilize for ten minutes, repeating until the reading is in band. York prints these as examples and says so, and the tool passes that scope through rather than presenting the increment as a universal specification.
- Rheem RD16AY / RD18AY section 5.7, and Lennox 13ACX 506374-01 page 20
- The two hazards this engine will not charge through. Rheem's instruction covers running a system at a suction pressure that will ice the evaporator coil, and it is quoted with its own scope, which names cooling mode. Lennox states the low-superheat floor below which refrigerant must not be added, because liquid reaching the compressor is damage happening in that instant rather than a charge level. Both are carried on every branch, including the branches where a charging instruction is being withheld.
- Copeland discharge-temperature guidance, and Proctor Engineering on airflow and capacity
- The two checks that sit beside the charge rather than inside it. Copeland's discharge-line temperature limit is what the tool watches for a compressor running hot. Proctor's finding that a passing temperature split can also mean low airflow AND low capacity together is why a passing split is not treated as proof the air side is healthy.
- The manufacturer installation books these steps quote
- INSTALLATION INSTRUCTIONS (Rheem · 92-110354-01-01 · read 2026-10-03 · a distributor's copy of Rheem's document; Rheem's own site did not serve it on 2026-10-03). Factory refrigerant: “VARIABLE SPEED R-454B” (the 1st page of the linked document). SHA-256 4b5f3d509c77d20b767b53772e3ee03c002958c05c29bcd6509c83151b6dfcf4, 10,280,945 bytes VARIABLE SPEED R-410A HEAT PUMP/ AIR CONDITIONING OUTDOOR UNITS INSTALLATION INSTRUCTIONS (Rheem · 92-104921-25-04 · read 2026-10-03 · a distributor's copy of Rheem's document; Rheem's own site did not serve it on 2026-10-03). Factory refrigerant: “VARIABLE SPEED R-410A” (the 1st page of the linked document). Series and equipment type: “HEAT PUMP/ AIR CONDITIONING” (the 1st page of the linked document). SHA-256 dfcd21d747330149fe34dabf6e356ca0dba438539b1c6369e5627b1a19efa8d0, 8,390,130 bytes R-454B HEAT PUMP (Rheem · 92-104921-51-03 · read 2026-10-03 · a retailer's copy of Rheem's document; Rheem's own site did not serve it on 2026-10-03). Factory refrigerant: “R-454B HEAT PUMP” (the 1st page of the linked document). SHA-256 2d38715ad32988a92403ca9c9edfb6d91b3825570eacbeb867c910f31685a81c, 10,561,052 bytes
- Honeywell, March 2016 version 8
- Retrofit Guidelines R-404A/R-507A to R-448A Solstice N40. Names, of the fluids this site carries, R-404A and R-448A. The sentences this site holds from it are at page 1 (read from the document's text, not checked on the printed page), page 3 (read from the document's text, not checked on the printed page) and page 4 (read from the document's text, not checked on the printed page). Read 2026-09-05.
- Honeywell, 3455 FP I (August 2019)
- HCFC/HFC to HFO Blend Retrofit Guidelines, Commercial Refrigeration (R-22/R-402A/R-404A/R-408A/R-507A to R-448A). Names, of the fluids this site carries, R-22, R-404A and R-448A. The sentences this site holds from it are at page 10 (read from the printed page), page 21 (read from the printed page) and page 22 (read from the document's text, not checked on the printed page). Read 2026-09-05 at prod-edam.honeywell.com. https://prod-edam.honeywell.com/content/dam/honeywell-edam/pmt/oneam/en-us/refrigerants/documents/Retrofit-guide-Solstice-N40-R448A-from-22-402-408-507-404.pdf
- Chemours, C-10023 (1/16)
- Opteon XP40 Retrofit Guidelines to Replace R-404A/R-507. January 2016. Names, of the fluids this site carries, R-404A and R-449A. The sentences this site holds from it are at page 3 (read from the document's text, not checked on the printed page) and page 4 (read from the document's text, not checked on the printed page). Read 2026-09-05 at www.opteon.com. https://www.opteon.com/en/-/media/files/opteon/opteon-xp40-retrofit-guidelines-r-404a-r-507.pdf
- Arkema (Forane), 2025 edition
- Forane Technical Digest. Names, of the fluids this site carries, R-404A. The sentences this site holds from it are at page 10 (read from the document's text, not checked on the printed page). Read 2026-09-05 at forane.arkema.com. https://forane.arkema.com/files/live/sites/shared_arkema/files/Fluorochemicals/2025%20Forane%20Technical%20Digest-FINAL-LR.pdf
- Arkema (Forane), PPC/SDC/08-2020
- Forane Technical Digest. August 2020. Names, of the fluids this site carries, R-22, R-404A, R-407A and R-407C. The sentences this site holds from it are at page 9 (read from the document's text, not checked on the printed page). Read 2026-09-05 at forane.arkema.com. https://forane.arkema.com/files/live/sites/fluorogases_forane_arkema/files/downloads/literature/forane-technical-digest.pdf
- Honeywell, G 525-013
- Honeywell Genetron 407C: Properties, Uses, Storage, and Handling. 2005. Names, of the fluids this site carries, R-22 and R-407C. The sentences this site holds from it are at page 4 (read from the document's text, not checked on the printed page) and page 10 (read from the document's text, not checked on the printed page). Read 2026-09-05 at prod-edam.honeywell.com. https://prod-edam.honeywell.com/content/dam/honeywell-edam/pmt/oneam/en-us/refrigerants/documents/pmt-am-genetron407c-refrigerant-handling-tech-guide1.pdf
- Copeland, 2021ET-31 (7/21)
- Refrigerant changeover guidelines HFC R-404A to R-407H/R-448A/R-449A/R-452A. July 2021. Names, of the fluids this site carries, R-404A, R-448A and R-449A. The sentences this site holds from it are at page 1 (read from the printed page) and page 2 (read from the document's text, not checked on the printed page). Read 2026-09-05 at webapps.copeland.com. https://webapps.copeland.com/online-product-information/Publication/LaunchPDF?Index=AEB&PDF=2021ECT-31
- Copeland, 95-14 R11 (7/21)
- Refrigerant changeover guidelines HCFC R-22 to HFC R-407A/C/F/H, R-448A, R-449A or R-427A. Revision 11, July 2021. Names, of the fluids this site carries, R-22, R-407A, R-407C, R-448A and R-449A. The sentences this site holds from it are at page 1 (read from the printed page) and page 2 (read from the document's text, not checked on the printed page). Read 2026-09-05 at webapps.copeland.com. https://webapps.copeland.com/online-product-information/Publication/LaunchPDF?Index=AEB&PDF=95-14
- Copeland, AE4-1344 R21
- Application Guidelines for Copeland RFT, RRT, RST Compressors. June 2024. Names, of the fluids this site carries, R-134a, R-290, R-404A, R-448A and R-449A. The sentences this site holds from it are at page 6 (read from the document's text, not checked on the printed page). Read 2026-09-05 at webapps.copeland.com. https://webapps.copeland.com/online-product-information/Publication/LaunchPDF?Index=AEB&PDF=1344
- Copeland, AE22-1182 R26
- Liquid Refrigerant Control in Refrigeration and Air Conditioning Systems. June 2024. Its superheat statements name no particular refrigerant, so it is cited wherever a commercial fluid is read. "A well designed, durable, and efficient compressor for refrigeration, air conditioning, or heat pump duty is primarily a vapor pump designed to handle a small quantity of liquid refrigerant and oil." The sentences this site holds from it are at pages 9 to 10 (read from the printed page). Read 2026-09-05 at webapps.copeland.com. https://webapps.copeland.com/online-product-information/Publication/LaunchPDF?Index=AEB&PDF=1182
- Copeland, AE 104 R2 (10/06)
- Refrigeration Manual Part 4, System Design. Revision 2, October 2006. Names, of the fluids this site carries, R-22. The sentences this site holds from it are at page 17-7 (read from the document's text, not checked on the printed page). Read 2026-09-05 at media.copeland.com. https://media.copeland.com/2c65d92c-bb4b-48e1-96e4-b1aa011847e5/AE104-System%20Design.pdf
- Copeland, AE-105 R3 (5/18)
- Refrigeration Manual Part 5, Installation and Service. Revision 3, May 2018. Its superheat statements name no particular refrigerant, so it is cited wherever a commercial fluid is read. Its measuring sentence sits under "5. Charging By Superheat", which opens: "On small unitary systems equipped with capillary tubes, the operating superheat may be used to determine the proper charge." Its receiver-charging statements are general. The sentences this site holds from it are at page 74 (read from the document's text, not checked on the printed page) and page 75 (read from the document's text, not checked on the printed page). Read 2026-09-05 at media.copeland.com. https://media.copeland.com/ff6556eb-dbad-4757-8ef4-b16d00377e59/AE105-Installation%20and%20Service.pdf
- Heatcraft Refrigeration Products, H-IM-CU-0725 Version 010, Part No. 25014601
- Installation and Operations Manual, Condensing Units. July 2025. Names, of the fluids this site carries, R-404A, R-407A, R-407C, R-448A and R-449A. The sentences this site holds from it are at page 7 (read from the document's text, not checked on the printed page), page 24 (read from the document's text, not checked on the printed page) and page 30 (read from the printed page). Read 2026-09-05 at assets.heatcraftrpd.com. https://assets.heatcraftrpd.com/literature/installation-and-operation-manual/condensing-units-and-packaged-systems/current/H-IM-CU.pdf
- Heatcraft Refrigeration Products, H-IM-UC-0626 Version 04, Part No. 25008201
- Installation and Operations Manual, Unit Coolers. June 2026. Names, of the fluids this site carries, R-404A, R-407A, R-407C, R-448A and R-449A. The sentences this site holds from it are at page 6 (read from the printed page). Read 2026-09-05 at www.heatcraftrpd.com. https://www.heatcraftrpd.com/dA/372b2b9e1e/H-IM-UC-HFC.pdf
This receipt binds the documents the charging engine consumes and the publisher documents the commercial-rack rows quote. It is not a claim that every sentence around the result is drawn from them, and it is not a substitute for the equipment's own instructions: where a nameplate or a service manual states a target, a tolerance or a procedure, that document governs and this tool says so. The California criteria are a state compliance standard, applied here because they are published, specific and checkable, not because they are the only correct way to charge a system. Where no primary publishes a band, this tool publishes none. The rack statements are quoted, not computed: a publisher's own conditions print on the adjacent line, and a document revised after the read date shown is not reflected until it is read again.
The full receipt, with every source and how each is cross-checked, is on the interactive Superheat & Subcooling Calculator.
Ask your assistant
The one rule that makes it reliable: name Intry in your question. That is what tells Claude to run the superheat_subcooling tool and answer with the real number, the verdict, and the citation. Leave Intry out and Claude may just guess from memory, which is exactly what you are trying to avoid. Type something like:
Inputs
Swipe the table sideways to see the rest of its columns. →
| Field | Required | Accepts | Range | What it is |
|---|---|---|---|---|
| refrigerant | yes | R-410A, R-407C, R-134a, R-404A, R-454B, R-32, R-22, R-407A, R-448A, R-449A, R-290 | Refrigerant, e.g. 'R-410A' or 'R-454B'. | |
| suctionPressure | yes | number | -14.7 or more | Suction (low-side) gauge pressure, psig. |
| suctionTemp | yes | number | -100 to 300 | Suction line temperature, °F. |
| liquidPressure | yes | number | -14.7 or more | Liquid (high-side) gauge pressure, psig. |
| liquidTemp | yes | number | -100 to 300 | Liquid line temperature, °F. |
| meteringDevice | optional | txv, fixed | txv or fixed orifice (default txv). On a fixed orifice the correct superheat is set by the load, and this tool cannot take the load inputs, so a fixed-orifice superheat is reported as measured and not graded (no static band is published for it), and no add or recover call is made from it. With a TXV, superheat is checked against California Title 24 Table RA3.2-1's 4 to 25 F default where the maker publishes none; subcooling is graded only against a maker's target. | |
| systemType | optional | no-receiver, receiver, unknown | Whether the system has a liquid receiver. On a receiver system the receiver holds the surplus charge, so subcooling stops indicating charge and this tool reports it as a measurement without grading it; on a comfort-cooling fluid superheat stays graded; on a commercial refrigeration fluid the Title 24 TXV-default superheat grade is withheld at every station answer, and the number prints without a grade. Omit only if unknown: the default is derived from the refrigerant's usual application, and it refuses rather than guesses. | |
| station | optional | evaporator-outlet, compressor-inlet | Where the suction line temperature was taken on a commercial refrigeration system: at the evaporator outlet (where the refrigerant producers state their figures) or at the compressor inlet (where the compressor maker states its floodback minimum). The two stations give different superheat figures. On a commercial refrigeration fluid, answering `compressor-inlet` withholds this tool's Title 24 TXV-default superheat grade (the number still prints) and prints the publishers' compressor-inlet figures with their conditions, never as a grade; on a comfort-cooling fluid the answer is reported as not used. Omit if unknown; the readout then asks where it was taken. On a commercial refrigeration fluid the Title 24 TXV-default superheat grade is withheld at every station answer including none, and the station answer chooses which publishers' figures print beside the number. |
Add Intry to Claude
One paste and Claude can run this tool and the other calculators on Intry's MCP server, right from your phone.
- Claude opens with the Intry connector already filled in. Review it and click Add.
- (If a field is blank, paste the link below into the URL field.)
- In any chat, tap + then Connectors and switch Intry on. Then name Intry in your question (“use Intry to…”) so Claude runs the tool instead of guessing.
https://www.intrysys.com/api/mcpNo login, no API key, and it works on every Claude plan, right from your phone.
Using ChatGPT, Cursor, or a dev tool? See the developer setup on the main page. The endpoint is https://www.intrysys.com/api/mcp.
Every answer comes with the locked modules each figure is traced to: the manufacturer PT tables behind the saturation temperatures, superheat and subcooling, and the code and service-literature constants copied from their documents behind the charge, metering, airflow, approach and discharge line figures, each quoted with its own source in the panel it appears in, so you can check it or show an inspector. The numbers come from the same calculator we run on intrysys.com, and our automated checks hold its answers against their sources before anything goes live, for the cases the checks cover, not for every input you can enter.