Run the Cold-Climate Heat Pump Capacity Calculator in your AI assistant

Through the free Intry MCP server, Claude, ChatGPT, or Cursor runs this exact calculator and hands back a verdict and the cited source, not a guess. Tool name: cold_climate_hp_capacity.

What it runs: How much heat a named cold-climate heat pump still makes at the outdoor temperature you give it, and how much of its rated capacity that is. The record rates nothing colder than a model's lowest rated row and nothing warmer than 47 F. For an outdoor temperature outside them the answer is the nearest row's capacity, labelled with that row's temperature; for a colder design temperature it gives no capacity, coverage or backup figure at the design temperature, only the capacity and the home's load at the lowest rated row, and for a design temperature warmer than 47 F no balance point, capacity, coverage or backup figure.

How it computes the answer

Interpolated by the engine from the AHRI-certified NEEP ccASHP rated points (MAX at 47/17/5F and the coldest rated row), clamped below the lowest rated row; the balance point is where that curve crosses the home's heat-loss load line.

What it cites

Your assistant calls the same engine the interactive calculator calls, with the inputs listed under Inputs. These are the sources that engine reads.

AHRI-certified NEEP ccASHP database
The printed rated points per model: MAX heating capacity at 47, 17, and 5F and at the coldest rated row, the AHRI-rated 47F capacity carried alongside, and the 5F COP at maximum capacity. Every number pins to one specific AHRI certificate and the exact NEEP outdoor-unit-number string (trailing wildcards preserved), read from the per-model NEEP JSON API and independently re-pulled to the digit (confirmed 2026-07-11).
Manufacturer submittal
The cross-check for the printed rated points. Where a brand markets a rounder cold-weather claim (for example 100 percent at 5F) that is not an AHRI-certified NEEP outdoor-unit record, the tool publishes the certified NEEP number instead and says so.
Linear interpolation of the MAX-capacity curve (derived)
Capacity at any outdoor temperature is a linear interpolation between the two bracketing printed points; the record rates nothing colder than a model's lowest rated row, so below it the figure is that row's, labelled with that row's temperature, and no colder number is computed; it rates nothing warmer than 47F either, so above 47F the figure is the 47F row's, labelled 47F. The balance point is where the MAX-capacity curve, interpolated between the printed rows, crosses the home's heat-loss load line (linear from zero at the ~65F no-heat temperature to the full design load at the design temperature), read within the rated rows; backup heat is the shortfall at the design temperature (none is computed for a design temperature colder than the lowest rated row or warmer than 47F), reported in BTU/hr and resistance kW (1 kW = 3412.142 BTU/hr).

These are AHRI-certified NEEP rated points, looked up per model and interpolated by the engine for the outdoor temperature you enter, never extrapolated below a model's coldest rated row. The manufacturer's engineering data or a Manual-J load calculation by an HVAC pro has final say on the equipment selection.

The full receipt, with every source and how each is cross-checked, is on the interactive Cold-Climate Heat Pump Capacity Calculator.

Ask your assistant

The one rule that makes it reliable: name Intry in your question. That is what tells Claude to run the cold_climate_hp_capacity tool and answer with the real number, the verdict, and the citation. Leave Intry out and Claude may just guess from memory, which is exactly what you are trying to avoid. Type something like:

“Use Intry to find the Mitsubishi Hyper-Heat heating capacity at 5F and how much it holds versus its rated 47F.”
“Ask Intry for the balance point and backup heat if my design load is 45,000 BTU at 5F on a Fujitsu XLTH.”

Inputs

Swipe the table sideways to see the rest of its columns. →

FieldRequiredAcceptsRangeWhat it is
modelyesmitsubishi-hyper-heat, mitsubishi-h2i-ductless, mitsubishi-smart-multi, bosch-ids, bosch-ids-premium, fujitsu-xlth, carrier-performance, daikin-aurora, lg-r32, gree, mrcoolModel slug, e.g. 'mitsubishi-hyper-heat', 'fujitsu-xlth', 'lg-r32'.
outdoorTempFoptionalnumber-30 to 65Outdoor temperature in F to read the capacity at (default 5).
designHeatLoadBtuoptionalnumbermore than 0, up to 200000Optional: the home's design heat load in BTU/hr, for the balance-point / backup-heat readout.
designTempFoptionalnumber-30 to 60Optional: the design outdoor temperature in F for the balance-point readout (default 5 when a design load is given).

Add Intry to Claude

One paste and Claude can run this tool and the other calculators on Intry's MCP server, right from your phone.

Add Intry to ClaudeOpens Claude with Intry already filled in.
  1. Claude opens with the Intry connector already filled in. Review it and click Add.
  2. (If a field is blank, paste the link below into the URL field.)
  3. In any chat, tap + then Connectors and switch Intry on. Then name Intry in your question (“use Intry to…”) so Claude runs the tool instead of guessing.
https://www.intrysys.com/api/mcp

No login, no API key, and it works on every Claude plan, right from your phone.

Using ChatGPT, Cursor, or a dev tool? See the developer setup on the main page. The endpoint is https://www.intrysys.com/api/mcp.

Every answer comes with the AHRI-certified NEEP ccASHP data it came from, so you can check it or show an inspector. The numbers come from the same calculator we run on intrysys.com, and our automated checks hold its answers against their sources before anything goes live, for the cases the checks cover, not for every input you can enter.